PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker

Der PXL6a-100 is specified for residual-current protection without overcurrent protection. Select it using the published voltage, current, pole and protection data, then confirm conductor coordination, fault conditions, enclosure requirements and local installation rules.

Polen:
2P / 4P
Nennstrom:
See technical table
Nennspannung:
AC 230/400V
Hauptfunktion:
residual-current protection without overcurrent protection
Auswahldaten:
30mA, 100mA or 300mA options
Standard
IEC 61008-1 family references

Product Overview

PXL6a-100 is a residual current circuit breaker for AC 230/400V applications. It is intended for residential, commercial and industrial circuits where a separate overcurrent device is coordinated; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.

residual-current protection without overcurrent protection is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.

Key Features

  • Published pole options: 2P / 4P.
  • Published electrical context: AC 230/400V.
  • Primary function: residual-current protection without overcurrent protection.
  • Selection reference: 30mA, 100mA or 300mA options.
  • Applicable standard reference: IEC 61008-1 family references.
  • Final selection must use the exact model table, drawings and installation instructions.

Typische Anwendungen

residential, commercial and industrial circuits where a separate overcurrent device is coordinated. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.

Applications and Selection Guide

Use the verified PXL6a-100 records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.

Selection point PXL6a-100 reference What the project must confirm
Rated current Use the exact model table Design current, conductor capacity, ambient and grouping
Voltage and frequency AC 230/400V Supply system and equipment rating
Masten 2P / 4P Conductors to be switched, protected or isolated
Protection / control residual-current protection without overcurrent protection Required function and adjacent-device coordination
Fault / residual data 30mA, 100mA or 300mA options Prospective short-circuit or leakage conditions

RCCB vs RCBO

An RCCB addresses residual-current protection; an RCBO combines residual-current and overcurrent functions. Choose the architecture required by the protection study.

Protection Function
Compare RCBO Options →

Model-Specific Ratings

Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.

Verified Data
View Technical Support →

Installation and Coordination

Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.

Engineering Check
Discuss a Configuration →

Ordering Information

State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.

Project Inputs
Send Project Details →

Ordering Guide

  1. State the exact model: PXL6a-100.
  2. Provide rated current and voltage from the published technical table.
  3. Confirm poles and the required protection, isolation or control function.
  4. Provide application, expected fault/leakage conditions, destination market and quantity.
  5. List accessory, terminal, documentation and approved marking or packaging requirements.

Installation and Coordination Checks

  • Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
  • Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
  • Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
  • Installation, testing and maintenance must be completed by qualified personnel under applicable rules.

Type designation

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image

Dimensions(mm)

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image

Technical Specifications

Parameter
Rated Voltage 230V AC(1P+N);400V AC(3P+N)
Rated Current (A) 25A, 40A, 63A, 80A, 100A
Rated Residual Operating Current 0.03A, 0.1A, 0.3A
Rated Residual Non-Operating Current 0.5IΔn
Type of Residual Current (with DC component) AC type, A type(In=25, 40, 63A)
Number of Poles 2P, 4P
Rated Conditional Short-Circuit Current 6000A
Rated Conditional Residual Short-Circuit Current 6000A
Rated Making and Breaking Capacity 500A (In=25, 40A) ; 10In (63, 80, 100A)
Rated Residual Making and Breaking Capacity 500A (In=25, 40A) ; 10In (63, 80, 100A)
Tightening Torque (2.5 ~ 3.0) N.m
Protection Class IP20
Pollution Degree 2
Installation Category Ⅱ
Standards GB 16916.1, IEC61008-1

Operating time (for residual current devices)

In (A) IΔn (A) Breaking time when the residual current equals the following values (s)
IΔn 2IΔn 5IΔn 5A, 10A, 20A, 50A, 100A, 200A IΔt
25 ~ 100A 0.03, 0.1, 0.3 0.1 0.05 0.04 0.04 0.04

Mechanical endurance&Electrical endurance

In (A) Number of operating cycles Operating frequency (cycles per hour)
Number of on-load
operating cycles
Number of no-load
operating cycles
25A 2000 2000 240
40A, 63A,
80A, 100A
2000 1000 120

Warum CHAC wählen?

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.

Cqw2 Series Air Circuit Breaker product image
30+

JAHRE ERFAHRUNG

Specialisiert auf die Herstellung von Niederspannungselektronik

Cqw2 Series Air Circuit Breaker product image
1100+

ARBEITER

Das professionelle Team gewährleistet eine stabile Qualität und Lieferfähigkeit.

Cqw2 Series Air Circuit Breaker product image
100 Millionen+

JAHRESTERNE VON POLES

Großserienfertigung zur Deckung der weltweiten Nachfrage

Cqw2 Series Air Circuit Breaker product image
90%

AUTOMATISCHE PRODUZIERUNG

Erweiterte Automatisierung für hohe Effizienz und Konsistenz

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image

Automatisierte Montagelinie

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image

Testlabor

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image

Injektion und Stempeln

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image

Qualitätskontrolle

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image
PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image
PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image
PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image
PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image

Strict quality control system ensures every product meets global standards.

Was können wir anpassen?

For PXL6a-100 projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.

Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Logo & Branding

Kundenspezifische Logo-Bedruckung, Lasermarkierung und Namensschild-Lösungen.

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Verpackung
Anpassung

Kundenspezifische Farbkartons, Kartons, Etiketten und Handbücher.

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Elektrisch
Anpassung

Current, voltage, breaking capacity, trip curve and other
special functions.

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Produkt
Aussehen

Anpassung der Wohnungsfarbe, des Griffs und des Erscheinungsbildes.

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Zertifizierung
Support

Products comply with international standards and market
requirements.

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Ingenieurwesen
Entwicklung

Auswertung der Zeichnungen, Prototypentest und Massenfertigung.

PXL6a-100 Electromagnetic Residual Current Operated Circuit Breaker product image

Herunterladen

PDF

PXB6-Serie Miniaturstromschutzschalter

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Kontaktieren Sie uns

PXL6a-100 Product FAQ

What is the PXL6a-100 used for?

The PXL6a-100 is specified for residual-current protection without overcurrent protection in AC 230/400V applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.

How does the PXL6a-100 work?

Its operating principle follows the documented function: residual-current protection without overcurrent protection. Use the exact model documentation for thresholds, timing, trip behaviour, terminals and test procedures.

How do I choose the PXL6a-100 rating and poles?

Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 2P / 4P; confirm neutral, polarity, conductors and isolation requirements.

What safety limitation applies to the PXL6a-100?

Do not treat the PXL6a-100 as a universal substitute for another device. Confirm 30mA, 100mA or 300mA options, the system voltage, fault or leakage conditions and any separate upstream protection before selection.

Can the PXL6a-100 be used in another circuit type?

Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.

How should the PXL6a-100 be installed and tested?

Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.

Confirm the Right PXL6a-100 Configuration

Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.

Angebot anfordern