PXB6L-63B Disjoncteur à courant résiduel électromagnétique

Product Features

■ Earth Leakage Protection – Detects electric shock or leakage current and cuts off power rapidly.

■ Overload Protection – Prevents equipment damage from circuit overload.

■ Short-Circuit Protection – Responds to short-circuit faults for enhanced safety.

■ Fast Response – Leakage tripping time ≤0.3s to ensure personal safety.

Ordering Specification

Please specify the following when ordering:

1.Product Model: PXB6L-63B

2.Number of Poles: 1P+N,2P,3P+N,4P

3.Rated Current & Tripping Curve: e.g., C/25A

  • Tripping Curve (Type): B, C, D
  • Rated Current (In): 6A, 10A, 16A, 20A, 25A, 32A,40A, 50A, 63A

4.Residual Current Operation:

  • Residual Current Type: B
  • Rated Residual Operating Current (IΔn): 30mA, 50mA,100mA, 300mA

Quantity: e.g., 100 pcs

5.Ordering Example:

PXB6L-63B 1P+N C/25A 30mA B 100 pcs

Caractéristiques techniques

Paramètre
Rated Voltage (V) 230V~(1P+N)/400V~(3P+N)
Rated Current (A) 6、10、16、20、25、32、40、50、63
Number of Poles 1P+N, 2P, 3P+N, 4P
Rated Short-Circuit Breaking Capacity Ics(A) 6000A
Rated Residual Operating Current IΔn(mA) 30、50、100、300
Rated Residual Non-Operating Current ΔIΔno(mA) 0.5IΔn
Rated Residual Make and Break Capacity IΔm(A) 3000A
Residual Current Tripping Threshold ≤0.3s
Residual Current Trip Type B Type
Mechanical Endurance ≥6000
Electrical Endurance ≥4000
Des courbes en virage B、C、D
Pollution Degree 2
Protection Class IP 20
Installation Category Ⅲ
Normes IEC61009-1, GB/T16917.1, IEC62423, GB/T22794
Certification CE CB CCC|DEKRA Certified

Tripping Characteristics (Reference Temperature: 30℃)

Article Curve de Triche Test Current (A) État initial Temps de déclenchement ou non-déclenchement Résultat attendu Commentaires
Delay ≤63 Froid 1.13Dans ≤1h Non-chocant  
Delay ≤63 Following previous test 1.45In <1h Desperance Current smoothly rises to specified value in 5s
Delay ≤32 Froid 2,55 en 1<t<60s Desperance  
Delay >32 Froid 2,55 en 1<t<120s Desperance  
Instantaneous Any value Froid 3、5、10In ≤0.1s Non-chocant B、C、D
Instantaneous Any value Froid 5、10、20In <0.1s Desperance B、C、D

Note: The term “cold” means that the test is carried out at a reference calibration temperature without load before the test.

Règles relatives aux conducteurs et section de la conduite

Section de cuivre (mm²) Courant nominal (A)
1 En ≤6
1.5 6<In≤13
2.5 13<In≤20
4 20<In≤25
6 25<In≤32
10 32<In≤50
16 50<In≤63

Designation de type

Des courbes en virage

Dimensions(mm)