{"id":5065,"date":"2026-10-24T16:00:00","date_gmt":"2026-10-24T16:00:00","guid":{"rendered":"https:\/\/chac-electric.com\/?p=5065"},"modified":"2026-10-29T09:26:32","modified_gmt":"2026-10-29T09:26:32","slug":"quest-ce-quun-contacteur-a-contacts-normalement-fermes-applications-et-guide-de-selection","status":"publish","type":"post","link":"https:\/\/chac-electric.com\/fr\/blog\/what-is-an-nc-contactor-normally-closed-contacts-applications-and-selection-guide\/","title":{"rendered":"Qu\u2019est-ce qu\u2019un contacteur NC ? Contacts normalement ferm\u00e9s, applications et guide de s\u00e9lection"},"content":{"rendered":"<article>\n<p>Une commande d\u2019un \u201c contacteur NC \u201d peut rev\u00eatir deux sens tr\u00e8s diff\u00e9rents : soit un contacteur dot\u00e9 d\u2019un contact auxiliaire normalement ferm\u00e9, soit un dispositif dont les contacts de puissance sont normalement ferm\u00e9s. Les confondre peut entra\u00eener un comportement de commande erron\u00e9 ou soumettre un petit contact auxiliaire \u00e0 un circuit pour lequel il n\u2019a jamais \u00e9t\u00e9 dimensionn\u00e9. Il convient donc de d\u00e9terminer la configuration des contacts \u00e0 partir du sch\u00e9ma \u00e9lectrique proprement dit, et non de l\u2019interpr\u00e9ter \u00e0 partir d\u2019une photographie du produit. Ce guide explique l\u2019\u00e9tat normal, distingue les fonctions de puissance et de commande, et indique comment sp\u00e9cifier la configuration des contacts, la bobine ainsi que les caract\u00e9ristiques nominales, sans faire d\u2019hypoth\u00e8ses infond\u00e9es sur les syst\u00e8mes d\u2019interverrouillage ou les fonctions de s\u00e9curit\u00e9.<\/p>\n<p>Un <strong>Contacteur \u00e0 contacts normalement ferm\u00e9s<\/strong> La description doit \u00eatre pr\u00e9cis\u00e9e. NC signifie \u00ab normalement ferm\u00e9 \u00bb : pour un dispositif \u00e9lectromagn\u00e9tique ordinaire sans verrouillage, le contact indiqu\u00e9 est ferm\u00e9 \u00e0 l\u2019\u00e9tat normal de non-alimentation et s\u2019ouvre lorsqu\u2019il est actionn\u00e9. La description pourrait ne concerner qu\u2019un contact auxiliaire, tandis que les p\u00f4les principaux restent normalement ouverts. V\u00e9rifiez le sch\u00e9ma de connexion r\u00e9el, le nombre de p\u00f4les, la cat\u00e9gorie d\u2019utilisation et l\u2019alimentation de la bobine. Ni les lettres NC ni un contact ferm\u00e9 au repos ne garantissent une fonction de s\u00e9curit\u00e9, un \u00e9tat de d\u00e9faillance contr\u00f4l\u00e9e ni l\u2019aptitude \u00e0 supporter le courant du moteur.<\/p>\n<h2>Quel est l\u2019\u00e9tat normal d\u2019un contact NC ?<\/h2>\n<p>Dans un contacteur ordinaire sans verrouillage, l\u2019\u00e9tat \u00ab normal \u00bb correspond \u00e0 l\u2019\u00e9tat non actionn\u00e9 et hors tension tel que d\u00e9crit dans la documentation du dispositif. Un contact normalement ouvert est ouvert dans cet \u00e9tat ; un contact normalement ferm\u00e9 est ferm\u00e9. Lorsque le m\u00e9canisme est activ\u00e9, leurs \u00e9tats changent en fonction de la conception r\u00e9elle.<\/p>\n<p>Ne g\u00e9n\u00e9ralisez pas cette description simplifi\u00e9e \u00e0 tous les dispositifs de commutation \u00e0 verrouillage, \u00e0 maintien m\u00e9canique ou sp\u00e9cialis\u00e9s. L\u2019\u00e9tat m\u00e9canique m\u00e9moris\u00e9 ou un m\u00e9canisme de fonctionnement diff\u00e9rent peuvent modifier la mani\u00e8re dont le sch\u00e9ma doit \u00eatre interpr\u00e9t\u00e9. R\u00e9f\u00e9rez-vous au sch\u00e9ma et \u00e0 la notice de fonctionnement du fabricant plut\u00f4t que de supposer qu\u2019une perte d\u2019alimentation de la bobine ram\u00e8ne syst\u00e9matiquement chaque appareil \u00e0 la m\u00eame position.<\/p>\n<table>\n<thead>\n<tr>\n<th>Description du contact<\/th>\n<th>\u00c9tat ordinaire non actionn\u00e9<\/th>\n<th>Ce qui reste \u00e0 v\u00e9rifier<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Auxiliaire normalement ouvert<\/td>\n<td>Ouvrir<\/td>\n<td>Classification de commande et circuit pr\u00e9vu<\/td>\n<\/tr>\n<tr>\n<td>Auxiliaire normalement ferm\u00e9<\/td>\n<td>Ferm\u00e9<\/td>\n<td>Classification de commande et circuit pr\u00e9vu<\/td>\n<\/tr>\n<tr>\n<td>Contact principal d'alimentation<\/td>\n<td>Comme indiqu\u00e9 sur le sch\u00e9ma exact<\/td>\n<td>Puissance, tension et courant<\/td>\n<\/tr>\n<tr>\n<td>Dispositif \u00e0 verrouillage ou dispositif sp\u00e9cialis\u00e9<\/td>\n<td>D\u00e9fini par son m\u00e9canisme et sa documentation<\/td>\n<td>R\u00e9initialiser le comportement et l\u2019\u00e9tat stock\u00e9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-full\"><img alt=\"NC describes a contact state, not every power pole; CHAC CQC6 contactor\" class=\"wp-image-5228\" decoding=\"async\" height=\"864\" loading=\"lazy\" src=\"https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline1-20261020-200k.webp\" style=\"width:100%;height:auto\" width=\"1536\" srcset=\"https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline1-20261020-200k.webp 1536w, https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline1-20261020-200k-300x169.webp 300w, https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline1-20261020-200k-1024x576.webp 1024w, https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline1-20261020-200k-768x432.webp 768w, https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline1-20261020-200k-18x10.webp 18w, https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline1-20261020-200k-600x338.webp 600w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><figcaption>NC d\u00e9signe un \u00e9tat de contact, et non chaque poteau \u00e9lectrique.<\/figcaption><\/figure>\n<h2>Un contact auxiliaire NC rend-il le circuit de puissance normalement ferm\u00e9 ?<\/h2>\n<p>Non. Les contacts principaux commutent la charge sp\u00e9cifi\u00e9e ; les contacts auxiliaires assurent des fonctions de commande, d\u2019indication ou de verrouillage, dans les limites de leurs caract\u00e9ristiques nominales. Un contacteur de puissance \u00e0 trois p\u00f4les normalement ouvert peut comporter un contact auxiliaire normalement ferm\u00e9. D\u00e9signer l\u2019ensemble du produit comme NF sans pr\u00e9ciser le groupe de contacts fait perdre cette distinction.<\/p>\n<p>Schneider Electric <a href=\"https:\/\/www.se.com\/us\/en\/faqs\/FA112430\/\" rel=\"nofollow noopener\" target=\"_blank\">FAQ FA112430<\/a>, modifi\u00e9 le 12, 2026, identifie 13\u201314 comme des contacts auxiliaires normalement ouverts et 21\u201322 comme des contacts auxiliaires normalement ferm\u00e9s sur les contacteurs TeSys D mentionn\u00e9s. Il s\u2019agit d\u2019un exemple de famille de produits tra\u00e7able, et non d\u2019une autorisation \u00e0 inf\u00e9rer la disposition des bornes d\u2019un appareil sans lien avec celui-ci. V\u00e9rifiez le marquage et le sch\u00e9ma du mod\u00e8le s\u00e9lectionn\u00e9.<\/p>\n<h2>Pourquoi les valeurs nominales des contacts auxiliaires diff\u00e8rent-elles des valeurs nominales des contacts principaux ?<\/h2>\n<p>Les groupes de contacts remplissent des fonctions diff\u00e9rentes. Un contacteur de moteur peut avoir une puissance nominale de AC-3, tandis que ses contacts auxiliaires sont soumis \u00e0 des valeurs nominales distinctes pour le circuit de commande. Le courant pertinent d\u00e9pend \u00e9galement de la tension de fonctionnement et du fait que la charge de commande soit en courant alternatif ou en courant continu. Une valeur de courant thermique n\u2019est pas une valeur nominale de commutation automatique pour une charge de commande inductive.<\/p>\n<p>Pour <strong>contacts normalement ferm\u00e9s<\/strong>, Cela rev\u00eat une importance particuli\u00e8re lors du commutage d\u2019une bobine, d\u2019un indicateur ou d\u2019un circuit d\u2019entr\u00e9e. Les charges d\u2019entr\u00e9e \u00e9lectroniques tr\u00e8s faibles doivent \u00e9galement faire l\u2019objet d\u2019une v\u00e9rification de la compatibilit\u00e9 avec la charge minimale des contacts. Le fait de choisir un contact uniquement parce que son courant nominal d\u00e9passe la charge en r\u00e9gime permanent peut conduire \u00e0 ignorer \u00e0 la fois les exigences relatives au service de commutation et celles relatives \u00e0 la fiabilit\u00e9 aux faibles niveaux de signal.<\/p>\n<h2>Comment les contacts NC sont-ils utilis\u00e9s dans les syst\u00e8mes d\u2019interverrouillage et de retour d\u2019information ?<\/h2>\n<p>Un contact auxiliaire NC peut faire partie d\u2019un interverrouillage \u00e9lectrique qui emp\u00eache la commande d\u2019un contacteur lorsque l\u2019autre est enclench\u00e9. Il peut \u00e9galement fournir un signal d\u2019\u00e9tat interpr\u00e9t\u00e9 par un contr\u00f4leur. Le circuit r\u00e9el et l\u2019analyse des d\u00e9faillances d\u00e9terminent la signification de ce signal ; un simple \u00e9tat du contact auxiliaire ne constitue pas la preuve que tous les p\u00f4les principaux sont ouverts.<\/p>\n<p>Lorsque la conception exige un verrouillage m\u00e9canique, des contacts en miroir, des contacts reli\u00e9s m\u00e9caniquement ou une fonction certifi\u00e9e pour la s\u00e9curit\u00e9, procurez-vous la documentation justificative exacte. Une simple d\u00e9signation NF ne garantit pas ces caract\u00e9ristiques. De m\u00eame, un signal de retour d\u2019information ne doit pas \u00eatre qualifi\u00e9 de \u201c s\u00fbr \u201d simplement parce qu\u2019il change d\u2019\u00e9tat lorsque l\u2019alimentation de la bobine est coup\u00e9e.<\/p>\n<table>\n<thead>\n<tr>\n<th>Fonction propos\u00e9e<\/th>\n<th>V\u00e9rification pertinente<\/th>\n<th>Ce que le NC \u00e0 lui seul ne prouve pas<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Verrouillage \u00e9lectrique<\/td>\n<td>Actual sequence and compatible contact arrangement<\/td>\n<td>Mechanical prevention of simultaneous closure<\/td>\n<\/tr>\n<tr>\n<td>Controller feedback<\/td>\n<td>Signal rating and interpretation<\/td>\n<td>All power poles are positively open<\/td>\n<\/tr>\n<tr>\n<td>Control-coil switching<\/td>\n<td>AC\/DC duty and contact rating<\/td>\n<td>Motor-load switching capacity<\/td>\n<\/tr>\n<tr>\n<td>Safety function<\/td>\n<td>Required certified components and system design<\/td>\n<td>A guaranteed safe state after any failure<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-full\"><img alt=\"A feedback contact is not proof of every power-pole state; CHAC CQC6 contactor\" class=\"wp-image-5229\" decoding=\"async\" height=\"864\" loading=\"lazy\" src=\"https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline2-20261020-200k.webp\" style=\"width:100%;height:auto\" width=\"1536\" srcset=\"https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline2-20261020-200k.webp 1536w, https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline2-20261020-200k-300x169.webp 300w, https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline2-20261020-200k-1024x576.webp 1024w, https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline2-20261020-200k-768x432.webp 768w, https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline2-20261020-200k-18x10.webp 18w, https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/10\/chac-real-product-5065-inline2-20261020-200k-600x338.webp 600w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><figcaption>A feedback contact is not proof of every power-pole state<\/figcaption><\/figure>\n<h2>Why should the coil command, auxiliary state and controller input be checked separately?<\/h2>\n<p>They describe three different things: what the controller requests, what the contact mechanism does and what the input circuit reports. For a healthy ordinary non-latching NC auxiliary, the expected unactuated contact is closed and the actuated contact is open, as defined by its diagram. The PLC&#8217;s displayed zero or one also depends on its input wiring and logic; NC does not automatically mean a displayed zero.<\/p>\n<p>Put those expected states beside the control drawing before the approved functional check. If the command changes but the reported state does not, investigate the actual coil supply, contact configuration, wiring and input interpretation rather than immediately declaring the main poles welded. The auxiliary&#8217;s behavior alone cannot establish the condition of every power contact. This separation is particularly useful after replacing a block or changing a controller program without changing the contactor body.<\/p>\n<h2>How should a buyer specify the contact configuration?<\/h2>\n<p>State the main power-pole arrangement separately from the auxiliary NO\/NC count. Then specify operational voltage, utilization category, current, coil supply and the exact accessories. Schneider&#8217;s <a href=\"https:\/\/productinfo.se.com\/tesysgigainstallationguide\/tesys-giga-series-giga-contactors-and-giga-thermal-overload-relays-installation-guide\/English\/TeSys%E2%84%A2%20Giga%20Series%20Giga%20Contactors%20and%20Giga%20Thermal%20Overload%20Relays%20Installation%20Guide_0000447511.xml\/$\/PanGu_LoadsCPT_0000507717\" rel=\"nofollow noopener\" target=\"_blank\">utilization-category guide<\/a>, DOCA0189EN-05, shows why a contactor&#8217;s load duty is part of its selection. Its <a href=\"https:\/\/www.se.com\/us\/en\/faqs\/FA105974\/\" rel=\"nofollow noopener\" target=\"_blank\">coordination guidance<\/a> also makes clear that short-circuit behavior belongs to a documented combination, not to the NC label.<\/p>\n<p>CHAC <a href=\"https:\/\/chac-electric.com\/fr\/product\/contacteur-industriel-ca-de-la-serie-cqc6-fabricant-oem\/\">CQC6 auxiliary contact options<\/a> include published F4 combinations such as F4-11 with 1NO + 1NC, F4-20 with 2NO and F4-02 with 2NC. These accessory descriptions do not convert the main poles into NC power contacts. Confirm the accessory&#8217;s compatibility and its own control ratings before ordering.<\/p>\n<p>For related industrial switching requirements, review the <a href=\"https:\/\/chac-electric.com\/fr\/product\/contacteur-a-haute-puissance-ac-de-la-serie-cqc1-et-accessoires\/\">CQC1 AC contactor family<\/a> against its own model data. Do not infer an NC power variant from the availability of an auxiliary block in another series. The <a href=\"https:\/\/chac-electric.com\/fr\/blog\/contacteur-normalement-ouvert-contre-normalement-ferme\/\">normally open versus normally closed contactor guide<\/a> provides a related explanation of the operating-state distinction.<\/p>\n<h2>What should be rechecked when a suppression module or auxiliary block changes?<\/h2>\n<p>Review the expected transition as well as the final state. Coil suppression can affect how quickly stored energy decays after the control signal is removed. Durakool&#8217;s <a href=\"https:\/\/www.durakool.com\/information\/technology\/application-notes\/laymans-guide-to-coil-suppression\/\" target=\"_blank\" rel=\"noopener nofollow\">Note technique sur l\u2019att\u00e9nuation des bobines<\/a> explains the release-time trade-off. Its relay examples do not supply a release-time specification for a CHAC contactor.<\/p>\n<p>Use the exact contactor, accessory and control-output instructions to define the permitted behavior. Under an approved commissioning procedure, check the command sequence, contact feedback and any required interlock response. Do not invent a universal delay or increase a software timeout simply to hide unexplained feedback. Keep the accepted component references and control-program revision with the result. A final NC continuity check cannot establish that a timed interlock or safety-related sequence has been validated.<\/p>\n<h2>What should be checked before an NC contact is replaced?<\/h2>\n<p>Record the original diagram, accessory code and circuit function before removing the device. With the system properly isolated and stored energy addressed, qualified personnel can compare the contact behavior with the specified states and inspect for damage. A continuity check alone does not establish the contact&#8217;s permitted switching duty or overall service condition.<\/p>\n<p>The replacement <strong>auxiliary contact block<\/strong> must preserve the intended logic as well as the mechanical fit. Check coil suppression and control timing where they affect the sequence. Investigate unexpected behavior rather than rewiring around an interlock or treating an NC contact as a universal substitute for a relay.<\/p>\n<h2>What do buyers ask about NC contactors?<\/h2>\n<h3>What is a NC contactor?<\/h3>\n<p>It is an ambiguous shorthand that may mean a contactor with an NC auxiliary contact or a device with NC power contacts. Specify which contact group is meant and verify the actual diagram.<\/p>\n<h3>What is the difference between a NC contactor and a NO contactor?<\/h3>\n<p>NC and NO describe the stated contact&#8217;s normal unactuated condition. The main and auxiliary contacts may have different arrangements, so the complete device cannot always be described by one label.<\/p>\n<h3>What is a NO NC contactor switch?<\/h3>\n<p>The expression usually refers to a switching device or contact set with normally open and normally closed functions. Confirm the exact product, contact diagram and ratings rather than relying on the phrase.<\/p>\n<h3>What is the difference between NC and NO contacts?<\/h3>\n<p>For an ordinary non-latching device, an NC contact is closed at rest and an NO contact is open at rest. Actuation changes their states according to the device design.<\/p>\n<h3>What does nc contactor do in a control circuit?<\/h3>\n<p>An NC auxiliary may be used for interlocking, indication or control within its rating. Its presence does not prove a safety function or that the main power poles are normally closed.<\/p>\n<h3>How is nc contactor different from a relay?<\/h3>\n<p>NC describes a contact state that can appear in either product. Select a relay or contactor by its actual load duty, ratings, coil, configuration and required approvals.<\/p>\n<h2>R\u00e9f\u00e9rences<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.se.com\/us\/en\/faqs\/FA112430\/\" target=\"_blank\" rel=\"noopener nofollow\">Schneider Electric FA112430: TeSys D NO\/NC auxiliary-terminal identification; modified May 12, 2026<\/a><\/li>\n<li><a href=\"https:\/\/productinfo.se.com\/tesysgigainstallationguide\/tesys-giga-series-giga-contactors-and-giga-thermal-overload-relays-installation-guide\/English\/TeSys%E2%84%A2%20Giga%20Series%20Giga%20Contactors%20and%20Giga%20Thermal%20Overload%20Relays%20Installation%20Guide_0000447511.xml\/$\/PanGu_LoadsCPT_0000507717\" target=\"_blank\" rel=\"noopener nofollow\">Schneider Electric DOCA0189EN-05: contactor utilization categories; accessed October 19, 2026<\/a><\/li>\n<li><a href=\"https:\/\/www.se.com\/us\/en\/faqs\/FA105974\/\" target=\"_blank\" rel=\"noopener nofollow\">Schneider Electric FA105974: short-circuit coordination; modified April 20, 2026<\/a><\/li>\n<li><a href=\"https:\/\/www.durakool.com\/information\/technology\/application-notes\/laymans-guide-to-coil-suppression\/\" target=\"_blank\" rel=\"noopener nofollow\">Durakool: A Layman\u2019s Guide to Coil Suppression; accessed October 19, 2026. Relay examples explain the mechanism, not CHAC contactor timing.<\/a><\/li>\n<\/ul>\n<h2>Conclusion<\/h2>\n<p>The useful distinction is between the state of a particular contact and the function of the complete switching device. Define whether NC refers to an auxiliary or a power contact, then verify the diagram, control or power duty, coil supply and compatible accessories. An NC contact can support an interlock or feedback circuit without establishing a certified safety function or proving that every main pole is open. Preserve the intended logic when replacing parts, and do not infer contact ratings from another group on the same device. CHAC publishes CQC6 auxiliary configurations and model-specific contactor information for this review. Using those records alongside the actual circuit drawing gives buyers a precise configuration to confirm instead of an ambiguous request for an NC contactor.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Comprenez le fonctionnement d\u2019un contacteur NC en s\u00e9parant les contacts auxiliaires normalement ferm\u00e9s des poteaux \u00e9lectriques, puis v\u00e9rifiez l\u2019alimentation de la bobine, les caract\u00e9ristiques des contacts et la logique de commande.<\/p>","protected":false},"author":1,"featured_media":6108,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5065","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"_links":{"self":[{"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/posts\/5065","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/comments?post=5065"}],"version-history":[{"count":3,"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/posts\/5065\/revisions"}],"predecessor-version":[{"id":5241,"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/posts\/5065\/revisions\/5241"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/media\/6108"}],"wp:attachment":[{"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/media?parent=5065"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/categories?post=5065"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chac-electric.com\/fr\/wp-json\/wp\/v2\/tags?post=5065"}],"curies":[{"name":"Bien jou\u00e9","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}