CQB2H-63 Miniature Circuit Breaker

The CQB2H-63 miniature circuit breaker provides overload and short-circuit protection within the published 6A–63A range. Its verified product data lists 10kA Icn, 1P / 2P / 3P / 4P and B / C / D. Final selection must match the conductor, load, prospective fault current, installation system and applicable local rules.

Poles:
1P / 2P / 3P / 4P
Rated Current:
6A–63A
Electrical Rating:
230/400V AC
Frequency:
50/60Hz
Breaking Data:
10kA Icn
Trip / Residual Type:
B / C / D
Standard:
IEC 60898-1; GB/T 10963.1
Mounting:
DIN-rail installation

Product Overview

CQB2H-63 is a 10kA Icn miniature circuit breaker covering 6A–63A. It is available with 1P / 2P / 3P / 4P and B / C / D trip options as stated in the product data.

The model data references IEC 60898-1; GB/T 10963.1. Standards, certification scope and technical documents must be confirmed for the ordered configuration and destination market.

Key Features

  • Published current range: 6A–63A.
  • Pole configuration: 1P / 2P / 3P / 4P.
  • Trip / protection option: B / C / D.
  • Short-circuit data: 10kA Icn.
  • Electrical reference: 230/400V AC, 50/60Hz.
  • Service-life data: ≥20,000 mechanical and ≥6,000 electrical operations.
  • Additional verified data: 4kV Uimp; IP20; 3.5N·m terminal torque; conductor reference up to 16mm².

Typical Applications

It is intended for AC distribution circuits where the selected current rating, curve, pole arrangement and breaking capacity match the conductor and system study. Typical project contexts include residential, commercial and light-industrial final distribution; suitability depends on the actual circuit rather than the application label alone.

Applications and Selection Guide

Use the product-specific values below as a shortlist, then validate the complete circuit design. Product ratings do not replace a fault-current study, conductor calculation, coordination review or applicable installation rules.

Selection point CQB2H-63 option What the project must confirm
Rated current 6A–63A Coordinate with design current, conductor ampacity, ambient temperature and grouping
Trip curve B / C / D Choose for load inrush and required fault-clearing performance, not by current alone
Breaking capacity 10kA Icn Confirm against the prospective short-circuit current at the installation point
Pole arrangement 1P / 2P / 3P / 4P Match supply system and local switching or isolation rules
Installation interface DIN-rail installation Check enclosure, rail/base, terminal and conductor compatibility

Breaking Capacity

10kA Icn is the published product value. Confirm the prospective short-circuit current at the installation point.

Fault LevelProject Selection

Trip and Load Behaviour

B / C / D is the available trip/protection option. Match it to load inrush and required disconnection performance.

Load InrushProject Selection

Pole Configuration

Available arrangement: 1P / 2P / 3P / 4P. Confirm which conductors must be switched and protected under local rules.

Circuit LayoutProject Selection

MCB or RCBO

An MCB does not replace residual-current protection where an RCD or RCBO is required.

Protection ScopeProject Selection

Ordering Guide

  1. Specify the exact model: CQB2H-63.
  2. State the required current rating within 6A–63A.
  3. Confirm pole arrangement: 1P / 2P / 3P / 4P.
  4. Confirm trip or protection option: B / C / D.
  5. Provide system voltage, expected fault level, destination market, quantity and any document requirements.

Installation and Coordination Checks

  • Verify conductor material and cross-section against the circuit calculation and the published terminal range.
  • Confirm the prospective short-circuit current does not exceed the applicable breaking rating.
  • Check upstream/downstream coordination, enclosure temperature, grouping, altitude and required clearances.
  • Installation, isolation, testing and maintenance must be carried out by qualified personnel under applicable rules.

Type designation

Tripping curves

Dimensions(unit:mm)

Technical Specifications

Parameter
Rated voltage 230V/400V (1P), 400V~ (2P/3P/4P)
Rated current 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Number of poles 1P, 2P, 3P, 4P
Rated short circuit breaking capacity Icn 10000 A
Mechanical & Electrical life Mechanical ≥ 20000, Electrical ≥ 6000
Tripping characteristics B, C, D
Tightening torque (N·m) 3.5
Pollution degree 2
Degree of protection IP20
Overvoltage category Ⅱ, Ⅲ
Standards IEC 60898-1, GB/T 10963.1

Table1 Tripping characteristics (Reference temp.30℃)

Item Tripping Curve Test current In(A) Initial Status Time limit for tripping or non-tripping Expected result Remarks
a B, C, D 1.13In Cold t ≤ 1h Non-tripping Current smoothly rises to specified value within 5s
b B, C, D 1.45In Following item a test t < 1h Tripping
c B, C, D 2.55In Cold 1s < t ≤ 60s (In ≤ 32A)
1s < t ≤ 120s (In > 32A)
Tripping
d B 3In Cold t ≤ 0.1s Non-tripping Switch on the power supply by closing the auxiliary switch
C 5In
D 10In
e B 5In Cold t < 0.1s Tripping Switch on the power supply by closing the auxiliary switch
C 10In
D 20In

Note: The term “cold” means that the test is carried out at a refererce calibration temperature without load before the test

Conductor requirements and cross section

Copper cross-section(mm²) Rated current In(A)
1 In≤6
1.5 6<In≤13
2.5 13<In≤20
4 20<In≤25
6 25<In≤32
10 32<In≤50
16 50<In≤63

Why Choose CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.


30+

YEARS EXPERIENCE

Specialized in low-voltage electrical manufacturing


1100+

EMPLOYEES

Professional team ensures stable quality and delivery


100M+

POLES ANNUAL CAPACITY

Large-scale production capacity to meet global demand


90%

AUTOMATED PRODUCTION

Advanced automation for high efficiency and consistency

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

IEC Certification
CE Certification
CB Certification
RoHS Certification
ISO 14001 Certification

Strict quality control system ensures every product meets global standards.

What Can We Customize?

For CQB2H-63 projects, CHAC can review private-label marking, packaging, appearance, available electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, MOQ and project feasibility.

Logo & Branding

Private-label marking and nameplate options are subject to artwork review and sample approval.

Logo & Branding

Packaging
Customization

Cartons, labels and manuals can be prepared for the approved order specification and destination market.

Packaging Customization

Electrical
Customization

Select from the published 6A–63A, 1P / 2P / 3P / 4P and B / C / D options; non-standard requests require technical evaluation.

Electrical Customization

Product
Appearance

Appearance options can be reviewed subject to tooling, MOQ, marking requirements and technical feasibility.

Product Appearance

Certification
Support

Datasheets, drawings and verified certificate information are supplied for the applicable approved configuration.

Certification Support

Engineering
Development

Project support may include drawing review, sample evaluation, testing and production planning, subject to technical approval.

Engineering Development

Download

PDF

CQB2 Series Miniature Circuit Breaker

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Contact Us

CQB2H-63 Product FAQ

What does 10kA mean on the CQB2H-63 MCB?

10kA is the published rated short-circuit breaking capacity, not the normal load current. It means the device's interrupting duty is stated as 10,000A under the applicable test conditions.

When is the 10kA CQB2H-63 the right choice?

Use a 10kA MCB only when the prospective short-circuit current and the protection-coordination study are within its published duty. A higher rating should not replace a fault-level calculation.

How should kA be interpreted on the CQB2H-63?

kA expresses short-circuit interrupting capacity in thousands of amperes. It is separate from the 6A–63A rated-current options used to select load and conductor protection.

Is 10kA the same as a 10,000A load rating?

No. The 10kA value relates to fault interruption. CQB2H-63 continuous rated-current choices remain within 6A–63A and must be coordinated with the conductor and design current.

What is the difference between a 10kA and 6kA MCB?

The main difference is the stated short-circuit breaking capacity. Choose between them from the prospective fault current, applicable standard, coordination requirements and verified product data—not from price or current rating alone.

Which CQB2H-63 curve and pole configuration should I choose?

CQB2H-63 is published with B, C and D curves and 1P–4P options. Match the curve to inrush and fault-clearing needs and match the poles to the supply, switching, neutral and isolation design.

Confirm the Right CQB2H-63 Configuration

Send your current rating, pole arrangement, trip option, system voltage, prospective fault level, destination market and quantity. CHAC will review the request against the published product range.

Request a Quote