{"id":2707,"date":"2026-07-18T01:46:14","date_gmt":"2026-07-18T01:46:14","guid":{"rendered":"https:\/\/chac-electric.com\/?post_type=product&#038;p=2707"},"modified":"2026-09-10T03:20:18","modified_gmt":"2026-09-10T03:20:18","slug":"pxb2ln-63-rcbo-residual-current-circuit-breaker-oem-manufacturer","status":"publish","type":"product","link":"https:\/\/chac-electric.com\/id\/product\/pxb2ln-63-rcbo-residual-current-circuit-breaker-oem-manufacturer\/","title":{"rendered":"PXB2Ln-63 RCBO (Residual Current Circuit Breaker) OEM Manufacturer"},"content":{"rendered":"<h2>PXB2Ln-63 Selection Summary<\/h2>\n<p>The PXB2Ln-63 RCBO covers 6A\u201363A, 1P+N and B \/ C trip curves. Published short-circuit data is 6kA. Residual-current options are 30mA (Type AC \/ Type A). Confirm every option against the conductor, load, fault level, supply system and applicable rules.<\/p>\n<h2>Ordering Details<\/h2>\n<p>State model, current rating, pole arrangement, trip curve, system voltage, destination market, quantity and required technical documents, including residual-current sensitivity and type. Options outside the published range require technical evaluation.<\/p>","protected":false},"excerpt":{"rendered":"<p>The <strong>PXB2Ln-63 RCBO<\/strong> provides overload, short-circuit and residual-current protection within its published 6A\u201363A range. Selection should be based on the circuit voltage, conductor, load behaviour, prospective fault current and applicable installation rules\u2014not the ampere rating alone.<\/p>\n<div class=\"product-specs-grid\">\n<div class=\"spec-item\">\n<div class=\"spec-title\">Poles:<\/div>\n<div class=\"spec-value\">1P+N<\/div>\n<\/div>\n<div class=\"spec-item\">\n<div class=\"spec-title\">Rated Current:<\/div>\n<div class=\"spec-value\">6A\u201363A<\/div>\n<\/div>\n<div class=\"spec-item\">\n<div class=\"spec-title\">Rated Voltage:<\/div>\n<div class=\"spec-value\">230V AC<\/div>\n<\/div>\n<div class=\"spec-item\">\n<div class=\"spec-title\">Frequency:<\/div>\n<div class=\"spec-value\">50\/60Hz<\/div>\n<\/div>\n<div class=\"spec-item\">\n<div class=\"spec-title\">Breaking Data:<\/div>\n<div class=\"spec-value\">6kA<\/div>\n<\/div>\n<div class=\"spec-item\">\n<div class=\"spec-title\">Trip Curve:<\/div>\n<div class=\"spec-value\">B \/ C<\/div>\n<\/div>\n<div class=\"spec-item\">\n<div class=\"spec-title\">Residual Sensitivity:<\/div>\n<div class=\"spec-value\">30mA<\/div>\n<\/div>\n<div class=\"spec-item\">\n<div class=\"spec-title\">Residual \/ Construction Type:<\/div>\n<div class=\"spec-value\">Type AC \/ Type A<\/div>\n<\/div>\n<\/div>\n<div style=\"display:flex;flex-wrap:wrap;gap:12px;margin-top:22px;align-items:center\">\n<a class=\"chac-home-ab-wz-about-btn\" style=\"display:inline-flex;align-items:center;justify-content:center;gap:12px;padding:14px 25px;border:1px solid #1456A6;border-radius:10px;background:#1456A6;color:#fff;font-size:16px;font-weight:600;text-decoration:none\" href=\"\/id\/contact-us\/\"><span style=\"color:#fff\">Request a Quote<\/span><span aria-hidden=\"true\" style=\"color:#fff;font-size:21px\">\u203a<\/span><\/a><br \/>\n<a class=\"chac-home-ab-wz-about-btn\" style=\"display:inline-flex;align-items:center;justify-content:center;gap:12px;padding:14px 25px;border:1px solid #1456A6;border-radius:10px;background:#1456A6;color:#fff;font-size:16px;font-weight:600;text-decoration:none\" href=\"\/wp-content\/uploads\/2026\/06\/PXB2-Series-Miniature-Circuit-Breaker.pdf\" target=\"_blank\" rel=\"noopener\"><span style=\"color:#fff\">View Technical Documents<\/span><span aria-hidden=\"true\" style=\"color:#fff;font-size:21px\">\u203a<\/span><\/a><\/div>","protected":false},"featured_media":1205,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[25,40],"product_tag":[],"class_list":["post-2707","product","type-product","status-publish","has-post-thumbnail","product_cat-terminal-electrical-appliances","product_cat-rcbo","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/chac-electric.com\/id\/wp-json\/wp\/v2\/product\/2707","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chac-electric.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chac-electric.com\/id\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/chac-electric.com\/id\/wp-json\/wp\/v2\/comments?post=2707"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chac-electric.com\/id\/wp-json\/wp\/v2\/media\/1205"}],"wp:attachment":[{"href":"https:\/\/chac-electric.com\/id\/wp-json\/wp\/v2\/media?parent=2707"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/chac-electric.com\/id\/wp-json\/wp\/v2\/product_brand?post=2707"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chac-electric.com\/id\/wp-json\/wp\/v2\/product_cat?post=2707"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chac-electric.com\/id\/wp-json\/wp\/v2\/product_tag?post=2707"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}