PXB6-MX Shunt Release

The PXB6-MX shunt release is specified for remote shunt release. Published data includes Us 230V AC 50Hz; Ui 415V and reliable operation within 70–110% of Us. Confirm the accessory interface, control circuit, wiring and destination-market requirements before ordering.

Function:
remote shunt release
Voltage:
Us 230V AC 50Hz; Ui 415V
Rating / range:
reliable operation within 70–110% of Us
Service data:
4,000 electrical operations
Standard:
IEC 60947-5-1
Installation:
for compatible PXB6 breaker accessory interface
Conductor:
0.5–2.5mm² conductor reference

Product Overview

PXB6-MX is a shunt release for low-voltage panel and breaker accessory systems. The summary below uses the published model record; it does not replace the complete drawing, wiring instructions or project design review.

Remote shunt release. reliable operation within 70–110% of Us is the published electrical reference. Compatibility, contact logic and installation details must be confirmed for the exact ordered version.

Key Features

  • Function: remote shunt release.
  • Electrical data: Us 230V AC 50Hz; Ui 415V; reliable operation within 70–110% of Us.
  • Installation reference: for compatible PXB6 breaker accessory interface.
  • Conductor reference: 0.5–2.5mm² conductor reference.
  • Service-life data: 4,000 electrical operations.
  • Standard/document reference: IEC 60947-5-1.

Typical Applications

Use it where a compatible breaker must be tripped from a remote control or emergency circuit. Confirm the control voltage, trip logic, accessory interface and safe isolation procedure; a shunt release is not an undervoltage release.

Applications and Selection Guide

Use the product-specific values below as a shortlist, then validate the complete circuit and mechanical interface. An accessory rating alone does not establish compatibility with every breaker, panel or control system.

Selection point PXB6-MX reference What the project must confirm
Primary function remote shunt release Confirm the required signal or protection function before ordering
Electrical reference Us 230V AC 50Hz; Ui 415V Match the project control or supply circuit
Rating / operating window reliable operation within 70–110% of Us Use the published range; do not infer missing ratings
Interface for compatible PXB6 breaker accessory interface Verify the compatible breaker, panel, base or rail interface
Wiring 0.5–2.5mm² conductor reference Final conductor and protection selection follows the project design and local rules
Documents IEC 60947-5-1 Request the exact drawing and applicable compliance documents for the ordered version

Function and signal path

Remote shunt release. Confirm whether the circuit needs status feedback, fault alarm, remote trip or voltage release.

shunt trip releaseProject Selection

Control-circuit fit

Us 230V AC 50Hz; Ui 415V. Match the control voltage and operating window to the project circuit; never assume a nearby rating is interchangeable.

remote emergency tripProject Selection

Mechanical interface

for compatible PXB6 breaker accessory interface. Confirm breaker family, rail/base or panel interface, clearances and maintenance access.

control-circuit selectionProject Selection

Wiring and documentation

0.5–2.5mm² conductor reference. Request the exact drawing and installation document for the ordered configuration.

Project DocumentationProject Selection

Ordering Guide

  1. Specify the exact model and accessory function: PXB6-MX, remote shunt release.
  2. State the control/supply voltage and any required operating window.
  3. Confirm the compatible breaker family, panel, base or DIN-rail interface.
  4. Provide quantity, destination market, wiring details and required technical documents.
  5. Ask CHAC to verify any non-standard marking, packaging or configuration request before production.

Installation and Coordination Checks

  • Use the exact product drawing and installation instructions for the ordered configuration.
  • Verify voltage, conductor, terminal, enclosure, clearances and maintenance access.
  • Check the accessory’s signal or trip logic against the control circuit and upstream/downstream protection.
  • Installation, testing and maintenance must be carried out by qualified personnel under applicable rules.

Type designation

Dimensions(mm)

Technical Specifications

Parameter
Rated operational voltage Us AC 230V50Hz
Rated insulation voltage Ui 415V
Operating characteristics The release unit can operate reliably within (70% to 110%) of US
Electrical life 4000 operations
Complies with standards IEC60947-5-1

Conductor requirements and cross section

Copper cross-section(mm2)
0.5~2.5

Why Choose CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.


30+

YEARS EXPERIENCE

Specialized in low-voltage electrical manufacturing


1100+

EMPLOYEES

Professional team ensures stable quality and delivery


100M+

POLES ANNUAL CAPACITY

Large-scale production capacity to meet global demand


90%

AUTOMATED PRODUCTION

Advanced automation for high efficiency and consistency

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

IEC Certification
CE Certification
CB Certification
RoHS Certification
ISO 14001 Certification

Strict quality control system ensures every product meets global standards.

What Can We Customize?

For PXB6-MX projects, CHAC can review private-label marking, packaging, approved electrical options, accessory interface and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, MOQ and project feasibility.

Logo & Branding

Private-label marking and nameplate options are subject to artwork review and sample approval.

Logo & Branding

Packaging
Customization

Cartons, labels and manuals can be prepared for the approved order specification and destination market.

Packaging Customization

Electrical
Customization

Published Us 230V AC 50Hz; Ui 415V, reliable operation within 70–110% of Us and interface options are reviewed against the ordered PXB6-MX configuration; non-standard requests require technical evaluation.

Electrical Customization

Product
Appearance

Appearance options can be reviewed subject to tooling, MOQ, marking requirements and technical feasibility.

Product Appearance

Certification
Support

Datasheets, drawings and verified document information are supplied for the applicable approved configuration.

Certification Support

Engineering
Development

Project support may include drawing review, sample evaluation, testing and production planning, subject to technical approval.

Engineering Development

Download

PDF

PXB6 Series Miniature Circuit Breaker

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Contact Us

PXB6-MX Product FAQ

What is the PXB6-MX used for?

The PXB6-MX provides remote shunt tripping for a compatible breaker system. It is selected as a control accessory, not as a standalone overcurrent device.

What is the difference between a shunt trip and an undervoltage release?

A shunt trip is generally energize-to-trip, while an undervoltage release responds to a loss or reduction of its control voltage. Confirm the required trip logic for the project.

What control voltage does the PXB6-MX use?

The published reference is Us 230V AC 50Hz; Ui 415V, with reliable operation within 70–110% of Us. Do not substitute another coil voltage without confirming the exact model.

Which breaker is compatible with the PXB6-MX?

The product record specifies a compatible for compatible PXB6 breaker accessory interface. Confirm the breaker model, interface and accessory combination from the drawing.

Can a shunt release provide overload protection?

No. It trips a compatible breaker remotely; overload and short-circuit protection come from the breaker and must be selected separately.

What wiring is listed for the PXB6-MX?

The published conductor reference is 0.5–2.5mm² conductor reference. Final wiring, isolation and control-circuit protection must follow the project design and instructions.

Confirm the Right PXB6-MX Configuration

Share the required function, voltage, interface, quantity, destination market and technical documents. CHAC will review the request against the published accessory data.

Request a Quote