CQHD SERIES PV Combiner Box

Il CHAC CQHD PV DC combiner box combines photovoltaic string inputs with DC circuit-breaker protection. Choose from six input/output configurations to match your PV array layout, and confirm the voltage and current ratings for the selected model.

Input / Output Configurations:
1 in / 1 out; 2 in / 1 out; 3 in / 1 out; 2 in / 2 out; 4 in / 2 out; 6 in / 2 out
Modelli:
CQHD-1/1, CQHD-2/1, CQHD-3/1, CQHD-2/2, CQHD-4/2, CQHD-6/2
Maximum System Voltage:
500V / 1000V DC, depending on model
Maximum Output Current:
32A / 63A, depending on model
DC Breaker Rated Current:
16A / 32A / 45A, depending on model
Enclosure:
Polycarbonate (PC); IP65; IK09
Installazione:
Wall mounting
Standard Reference:
IEC/EN 60947-3

Riassunto del prodotto

Il CHAC CQHD PV combiner box integrates DC circuit-breaker protection with PV string combining, surge protection and fuse components. Select the exact input/output model: the voltage, breaker current and maximum output current are not identical across all versions.

For importers, distributors and equipment manufacturers, CHAC can review the requested configuration against the circuit requirements and destination-market documents. Agree the exact model, drawings and marking requirements before sample approval or a repeat order.

Key Selection Points

  • Input/output choice: 1/1, 2/1, 3/1, 2/2, 4/2 or 6/2. Confirm which strings feed each output and the inverter arrangement.
  • Voltage options: 500V / 1000V DC according to model. Some variants list only 1000V; confirm the exact version.
  • Breaker current: 16A / 32A / 45A according to model. This is distinct from the listed 32A / 63A maximum output rating.
  • Enclosure: PC; IP65 / IK09; wall mounting. Confirm gland selection, sealing and service space for the actual installation.

Applicazioni tipiche

Evaluate CQHD for PV DC assemblies requiring the specified breaker-based protection arrangement. Use the inverter input limits, PV string design and assembly drawing to choose the box rather than selecting only by enclosure size or string count.

Modulazioni e Guida alla selezione

Elemento selezionabile CQHD configuration Cosa verificare
Input/output choice 1/1, 2/1, 3/1, 2/2, 4/2 or 6/2 Confirm which strings feed each output and the inverter arrangement.
Voltage options 500V / 1000V DC according to model Some variants list only 1000V; confirm the exact version.
Breaker current 16A / 32A / 45A according to model This is distinct from the listed 32A / 63A maximum output rating.
Contenitore PC; IP65 / IK09; wall mounting Confirm gland selection, sealing and service space for the actual installation.

Use these checks to compare the protection function, configuration and related CHAC products before specifying CQHD. Related products are selection alternatives or system components, not automatic replacements.

Approve the string grouping and protection together

Select the voltage version, input/output layout, fuse links, DC breaker and SPD as a coordinated assembly.

SelectionConfigurazioneTechnical Review

Review CQHS in the PV system

The CHAC CQHS PV DC combiner box combines photovoltaic string inputs with a DC isolator for DC-side disconnection. Choose from six input/output configurations to match your PV array layout, and confirm the voltage and current ratings for the selected model.

Related ProductSystem DesignVerify Compatibility

Review CQBD-63 in the PV system

The CHAC CQBD-63 DC circuit breaker offers overload and short-circuit protection with a non-polar design and contact-position indication. One- to four-pole versions cover DC voltages from 300V to 1200V; match the pole arrangement and tripping characteristic to the circuit.

Related ProductSystem DesignVerify Compatibility

Need Help Specifying CQHD?

Send the circuit requirements, selected configuration, destination market and quantity for a model-specific review.

Richiedi un preventivo

Do not confuse breaker current with maximum output current

The CQHD tables list both values. For example, the 2/1 configuration lists a 32A DC breaker and a 63A maximum output current. That does not authorize continuous operation at 63A through the 32A breaker. Confirm the limiting component and the complete assembly duty.

Approve the string grouping and protection together

Select the voltage version, input/output layout, fuse links, DC breaker and SPD as a coordinated assembly. Compare maximum string voltage and current with the inverter input requirements, and obtain the exact drawing before installation or repeat procurement.

How to Specify a CQHD Order

Use the configuration details below in the purchase specification. Keep the approved drawing revision and product identification with the order so repeat deliveries can be checked consistently.

Order detail Information to include
Input/output choice 1/1, 2/1, 3/1, 2/2, 4/2 or 6/2 — Confirm which strings feed each output and the inverter arrangement.
Voltage options 500V / 1000V DC according to model — Some variants list only 1000V; confirm the exact version.
Breaker current 16A / 32A / 45A according to model — This is distinct from the listed 32A / 63A maximum output rating.
Contenitore PC; IP65 / IK09; wall mounting — Confirm gland selection, sealing and service space for the actual installation.
Project and documents Supply the application, installation conditions and destination-market document requirements.
Quantity and identification State the quantity, sample requirement, packaging language and any proposed branding; confirm feasibility before approval.

Check Installation Fit Before Approval

  • Use the CQHD dimension drawing to verify mounting, terminal access, operating clearance and conductor bending space.
  • Confirm conductor preparation, terminal compatibility and tightening instructions for the exact configuration. A conductor reference table does not replace project cable sizing.
  • Review temperature, enclosure conditions and the protective arrangement with the equipment designer. Do not infer compatibility from a similar model name.
  • Have qualified personnel install and verify the equipment using the model instructions and applicable isolation and testing procedures.

Technical Data

Contenitore combinato CQHD-1/1 PV

Specificazione
  CQHD-1/1 Wiring diagram
Input 1 strings
Output 1 strings
Max Voltage 500 V 1000V
Rated Current of DC Breaker 16A 16A
Max Current Output 32A 32A
Contenitore
Material PC
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-9;L218*W200*H100mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
Ambiente
Operating temperature -20℃ – +60℃
Humidity 99%
Altitude 2000M
Installazione Wall Mounting

Modulo di collegamento PV CQHD-2/1

Specificazione
  CQHD-2/1 Wiring diagram
Input 2 strings
Output 1 strings
Max Voltage 1000V
Rated Current of DC Breaker 32A
Max Current Output 63A
Contenitore
Material  
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-13;L296*W230*H120mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
Ambiente
Operating temperature -20℃ – +60℃
Humidity 99%
Altitude 2000M
Installazione Wall Mounting

Modulo di combinazione CQHD-2/2 PV

Specificazione
  CQHD-2/2 Wiring diagram
Input 2 strings
Output 2 strings
Max Voltage 500 V 1000V
Rated Current of DC Breaker 16A 16A
Max Current Output 32A 32A
Contenitore
Material PC
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-18;L386*W230*H120mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
Ambiente
Operating temperature -20℃ – +60℃
Humidity 99%
Altitude 2000M
Installazione Wall Mounting

Contenitore combinato CQHD-3/1 PV

Specificazione
  CQHD-3/1 Wiring diagram
Input 3 strings
Output 1 strings
Max Voltage 500 V 1000V
Rated Current of DC Breaker 45A 45A
Max Current Output 63A 63A
Contenitore
Material  
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-13:L296*W230*H120mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
Ambiente
Operating temperature -20℃ – +60℃
Humidity 99%
Altitude 2000M
Installazione Wall Mounting

Modulo di combinazione CQHD-4/2 PV

Specificazione
  CQHD-4/2 Wiring diagram
Input 4 strings
Output 2 strings
Max Voltage 500 V 1000V
Rated Current of DC Breaker 32A 32A
Max Current Output 63A 63A
Contenitore
Material PC
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-26;L296*W390*H130mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
Ambiente
Operating temperature -20℃ – +60℃
Humidity 99%
Altitude 2000M
Installazione Wall Mounting

Contachilometri CQHD-6/2 PV

Specificazione
  CQHD-6/2 Wiring diagram
Input 6 strings
Output 2 strings
Max Voltage 1000V
Rated Current of DC Breaker 45A
Max Current Output 63A
Contenitore
Material PC
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-26:L296*W390*H130mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
Ambiente
Operating temperature -20℃ – +60℃
Humidity 99%
Altitude 2000M
Installazione Wall Mounting

Perché scegliere CHAC

CHAC Electric supplies electrical protection and control products for importers, distributors and equipment brands. For CQHD, agree the configuration, technical documents, approved sample and identification requirements before production. The company facilities shown below provide company context, not a claim that every model uses the same production or test process.

01

CONFIRM THE SPECIFICATION

Agree the CQHD configuration, circuit duty and installation requirements.

02

REVIEW THE DOCUMENTS

Confirm model-specific drawings and destination-market requirements.

03

APPROVE THE SAMPLE

Record the accepted configuration and marking requirements.

04

DEFINE ORDER CHECKS

Agree packaging, identification and delivery requirements in the quotation.

CHAC Automated Assembly Line

Linea di assemblaggio automatizzata

CHAC Testing Laboratory

Laboratorio di test

CHAC Injection & Stamping

Iniezione e stampaggio

CHAC Quality Inspection

Ispezione di qualità

Cosa possiamo personalizzare?

Discuss CQHD product identification, packaging and documentation with CHAC. Each proposed change is subject to technical feasibility, marking rules and approval of the exact order; no altered rating or certification is implied.

Logo e branding

Submit logo artwork and marking requirements for review against the available print area and mandatory product markings.

CHAC CQHD product view

Packaging & Manuals

Define carton labels, packaging language, product identification and instruction requirements for the destination market.

CHAC CQHD product view

Configuration Selection

Specify CQHD with the required input/output choice, operating conditions and protection duty. Confirm the complete order combination.

CHAC CQHD product view

Assembly Requirements

Provide the mounting and connection requirements for review. Changes to the housing, terminals or operating arrangement require engineering approval.

CHAC CQHD product view

Market Documentation

Request documents covering the exact CQHD model and destination market. A standard reference alone is not evidence of certification.

CHAC CQHD product view

Sample Approval

Agree the sample specification, drawing revision and acceptance criteria before confirming a production order.

CHAC CQHD product view

Technical Documents and Support

DOC

CQHD Technical Documents

Request the CQHD datasheet, configuration drawing, installation instructions and available model-specific market documents.Request Datasheet

SUP

Necessita di documenti tecnici?

Send the application, electrical requirements, assembly layout and destination market for configuration and document review.Contattaci

CQHD Product FAQ

How many PV strings can a CQHD box combine?

The series lists 1/1, 2/1, 3/1, 2/2, 4/2 and 6/2 input/output configurations. Confirm the internal grouping and inverter compatibility for the exact model; the total input count alone does not determine the MPPT arrangement.

Can a 63A maximum output rating override a 32A breaker rating?

No. The installed protective device and the other assembly limits still apply. Where a CQHD table lists a 32A breaker and 63A maximum output, confirm the intended duty; do not treat 63A as an authorized continuous current through that breaker.

Can I use any CQHD box at 1000V DC?

Order the voltage version documented for the exact model and confirm all installed components and wiring. Do not assume that a 500V version becomes a 1000V assembly because another version has that rating.

How should the PV string fuse be selected?

Check string current, reverse-current exposure, module maximum series-fuse rating and local rules. Confirm the fuse-link part number and rating in the CQHD assembly schedule. Do not select a fuse solely from the fuse holder’s maximum current.

Does the CQHD enclosure rating cover any outdoor installation?

No enclosure rating removes the need to assess exposure, temperature, cable entries, sealing and mounting. Preserve the specified IP65 construction during installation and confirm any site conditions outside the approved assembly requirements.

What information is needed to quote a CQHD box?

Provide string count and grouping, maximum PV voltage, string current, inverter model and MPPT inputs, required protection, cable details, site conditions, quantity and destination market. Agree the drawing and component schedule before production.

Specify the Right CQHD Configuration

Send CHAC your required configuration, application, destination market and estimated quantity. We will review the requested specification and provide the relevant technical documents and commercial proposal.

Richiedi un preventivo