PXB6-SD Alarm Contact

The PXB6-SD alarm contact is specified for alarm contact for fault-trip indication. Published data includes AC 230V / DC 110V and AC-15 230V 6A; DC-13 110V 1A. Confirm the accessory interface, control circuit, wiring and destination-market requirements before ordering.

Function:
alarm contact for fault-trip indication
Voltage:
AC 230V / DC 110V
Rating / range:
AC-15 230V 6A; DC-13 110V 1A
Service data:
10,000 mechanical operations
Standard:
IEC 60947-5-1
Installation:
for compatible PXB6 breaker accessory interface
Conductor:
0.5–2.5mm² conductor reference

Product Overview

PXB6-SD is a alarm contact for low-voltage panel and breaker accessory systems. The summary below uses the published model record; it does not replace the complete drawing, wiring instructions or project design review.

Alarm contact for fault-trip indication. AC-15 230V 6A; DC-13 110V 1A is the published electrical reference. Compatibility, contact logic and installation details must be confirmed for the exact ordered version.

Key Features

  • Function: alarm contact for fault-trip indication.
  • Electrical data: AC 230V / DC 110V; AC-15 230V 6A; DC-13 110V 1A.
  • Installation reference: for compatible PXB6 breaker accessory interface.
  • Conductor reference: 0.5–2.5mm² conductor reference.
  • Service-life data: 10,000 mechanical operations.
  • Standard/document reference: IEC 60947-5-1.

Typical Applications

Use it where a breaker fault trip must be reported to a panel, PLC, BMS or audible signaling circuit. An alarm contact should not be described as a normal auxiliary status contact; confirm the target breaker's accessory interface and the project's alarm logic.

Applications and Selection Guide

Use the product-specific values below as a shortlist, then validate the complete circuit and mechanical interface. An accessory rating alone does not establish compatibility with every breaker, panel or control system.

Selection point PXB6-SD reference What the project must confirm
Primary function alarm contact for fault-trip indication Confirm the required signal or protection function before ordering
Electrical reference AC 230V / DC 110V Match the project control or supply circuit
Rating / operating window AC-15 230V 6A; DC-13 110V 1A Use the published range; do not infer missing ratings
Interface for compatible PXB6 breaker accessory interface Verify the compatible breaker, panel, base or rail interface
Wiring 0.5–2.5mm² conductor reference Final conductor and protection selection follows the project design and local rules
Documents IEC 60947-5-1 Request the exact drawing and applicable compliance documents for the ordered version

Function and signal path

Alarm contact for fault-trip indication. Confirm whether the circuit needs status feedback, fault alarm, remote trip or voltage release.

fault contactProject Selection

Control-circuit fit

AC 230V / DC 110V. Match the control voltage and operating window to the project circuit; never assume a nearby rating is interchangeable.

alarm signalingProject Selection

Mechanical interface

for compatible PXB6 breaker accessory interface. Confirm breaker family, rail/base or panel interface, clearances and maintenance access.

auxiliary versus alarm contactProject Selection

Wiring and documentation

0.5–2.5mm² conductor reference. Request the exact drawing and installation document for the ordered configuration.

Project DocumentationProject Selection

Ordering Guide

  1. Specify the exact model and accessory function: PXB6-SD, alarm contact for fault-trip indication.
  2. State the control/supply voltage and any required operating window.
  3. Confirm the compatible breaker family, panel, base or DIN-rail interface.
  4. Provide quantity, destination market, wiring details and required technical documents.
  5. Ask CHAC to verify any non-standard marking, packaging or configuration request before production.

Installation and Coordination Checks

  • Use the exact product drawing and installation instructions for the ordered configuration.
  • Verify voltage, conductor, terminal, enclosure, clearances and maintenance access.
  • Check the accessory’s signal or trip logic against the control circuit and upstream/downstream protection.
  • Installation, testing and maintenance must be carried out by qualified personnel under applicable rules.

Type designation

Dimensions(mm)

Technical Specifications

Parameter  
AC-15 Rated Operational Voltage AC 230V 50Hz
Rated operating current 6A
DC-13 Rated Operational Voltage DC110V
Rated operating current 1A
Mechanical Life 10000
Standards IEC 60947-5-1

Conductor requirements and cross section

Copper cross-section(mm2)
0.5~2.5

Why Choose CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.


30+

YEARS EXPERIENCE

Specialized in low-voltage electrical manufacturing


1100+

EMPLOYEES

Professional team ensures stable quality and delivery


100M+

POLES ANNUAL CAPACITY

Large-scale production capacity to meet global demand


90%

AUTOMATED PRODUCTION

Advanced automation for high efficiency and consistency

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

IEC Certification
CE Certification
CB Certification
RoHS Certification
ISO 14001 Certification

Strict quality control system ensures every product meets global standards.

What Can We Customize?

For PXB6-SD projects, CHAC can review private-label marking, packaging, approved electrical options, accessory interface and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, MOQ and project feasibility.

Logo & Branding

Private-label marking and nameplate options are subject to artwork review and sample approval.

Logo & Branding

Packaging
Customization

Cartons, labels and manuals can be prepared for the approved order specification and destination market.

Packaging Customization

Electrical
Customization

Published AC 230V / DC 110V, AC-15 230V 6A; DC-13 110V 1A and interface options are reviewed against the ordered PXB6-SD configuration; non-standard requests require technical evaluation.

Electrical Customization

Product
Appearance

Appearance options can be reviewed subject to tooling, MOQ, marking requirements and technical feasibility.

Product Appearance

Certification
Support

Datasheets, drawings and verified document information are supplied for the applicable approved configuration.

Certification Support

Engineering
Development

Project support may include drawing review, sample evaluation, testing and production planning, subject to technical approval.

Engineering Development

Download

PDF

PXB6 Series Miniature Circuit Breaker

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Contact Us

PXB6-SD Product FAQ

What does the PXB6-SD indicate?

The PXB6-SD is intended to signal a breaker fault trip. It should be evaluated as an alarm contact, not assumed to follow every normal manual open/close operation.

What is the difference between an alarm contact and an auxiliary contact?

An alarm contact is used to report a fault-trip condition, while an auxiliary contact normally reports the breaker's open/closed status. The exact contact logic must be verified from the product drawing.

What ratings are published for the PXB6-SD?

The published ratings are AC-15 230V 6A; DC-13 110V 1A with AC 230V / DC 110V. Confirm the connected PLC, indicator or audible alarm circuit is within those values.

Can the PXB6-SD drive an audible alarm directly?

It can be part of an alarm circuit, but the complete circuit must be checked for voltage, current, isolation and any relay or interface required by the project.

Which breaker is the PXB6-SD compatible with?

The PXB6-SD is described as a modular accessory for a compatible breaker family. Confirm exact breaker model and interface before ordering.

How should the PXB6-SD be tested?

Use the approved product instructions and a controlled fault-simulation or functional test method suitable for the installed system. Testing must be performed by qualified personnel.

Confirm the Right PXB6-SD Configuration

Share the required function, voltage, interface, quantity, destination market and technical documents. CHAC will review the request against the published accessory data.

Request a Quote