Disjuntor Diferencial Residual Eletromagnético PXL6a-100

O PXL6a-100 is specified for residual-current protection without overcurrent protection. Select it using the published voltage, current, pole and protection data, then confirm conductor coordination, fault conditions, enclosure requirements and local installation rules.

Polacos:
2P / 4P
Corrente Nominal:
See technical table
Tensão Nominal:
AC 230/400V
Primary Function:
residual-current protection without overcurrent protection
Selection Data:
30mA, 100mA or 300mA options
Normal
IEC 61008-1 family references

Visão Geral do Produto

PXL6a-100 is a residual current circuit breaker for AC 230/400V applications. It is intended for residential, commercial and industrial circuits where a separate overcurrent device is coordinated; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.

residual-current protection without overcurrent protection is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.

Principais Características

  • Published pole options: 2P / 4P.
  • Published electrical context: AC 230/400V.
  • Primary function: residual-current protection without overcurrent protection.
  • Selection reference: 30mA, 100mA or 300mA options.
  • Applicable standard reference: IEC 61008-1 family references.
  • Final selection must use the exact model table, drawings and installation instructions.

Aplicações Típicas

residential, commercial and industrial circuits where a separate overcurrent device is coordinated. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.

Guia de Candidaturas e Seleção

Use the verified PXL6a-100 records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.

Ponto de seleção PXL6a-100 reference O que o projeto deve confirmar
Corrente nominal Use the exact model table Design current, conductor capacity, ambient and grouping
Tensão e frequência AC 230/400V Sistema de alimentação e classificação de equipamento
Polacos 2P / 4P Conductors to be switched, protected or isolated
Protection / control residual-current protection without overcurrent protection Required function and adjacent-device coordination
Fault / residual data 30mA, 100mA or 300mA options Prospective short-circuit or leakage conditions

RCCB vs RCBO

An RCCB addresses residual-current protection; an RCBO combines residual-current and overcurrent functions. Choose the architecture required by the protection study.

Protection Function
Compare RCBO Options →

Model-Specific Ratings

Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.

Verified Data
View Technical Support →

Installation and Coordination

Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.

Engineering Check
Discuss a Configuration →

Ordering Information

State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.

Project Inputs
Send Project Details →

Guia de Encomenda

  1. State the exact model: PXL6a-100.
  2. Provide rated current and voltage from the published technical table.
  3. Confirm poles and the required protection, isolation or control function.
  4. Provide application, expected fault/leakage conditions, destination market and quantity.
  5. List accessory, terminal, documentation and approved marking or packaging requirements.

Verificações de Instalação e Coordenação

  • Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
  • Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
  • Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
  • Installation, testing and maintenance must be completed by qualified personnel under applicable rules.

Designação do tipo

Dimensões (mm)

Especificações Técnicas

Parâmetro
Tensão Nominal 230V AC(1P+N);400V AC(3P+N)
Rated Current (A) 25A, 40A, 63A, 80A, 100A
Rated Residual Operating Current 0.03A, 0.1A, 0.3A
Rated Residual Non-Operating Current 0.5IΔn
Type of Residual Current (with DC component) AC type, A type(In=25, 40, 63A)
Número de Polos 2P, 4P
Rated Conditional Short-Circuit Current 6000A
Rated Conditional Residual Short-Circuit Current 6000A
Rated Making and Breaking Capacity 500A (In=25, 40A) ; 10In (63, 80, 100A)
Rated Residual Making and Breaking Capacity 500A (In=25, 40A) ; 10In (63, 80, 100A)
Tightening Torque (2.5 ~ 3.0) N.m
Protection Class IP20
Pollution Degree 2
Installation Category
Normas GB 16916.1, IEC61008-1

Operating time (for residual current devices)

In (A) IΔn (A) Breaking time when the residual current equals the following values (s)
IΔn 2IΔn 5IΔn 5A, 10A, 20A, 50A, 100A, 200A IΔt
25 ~ 100A 0.03, 0.1, 0.3 0.1 0.05 0.04 0.04 0.04

Mechanical endurance&Electrical endurance

In (A) Number of operating cycles Operating frequency (cycles per hour)
Number of on-load
operating cycles
Number of no-load
operating cycles
25A 2000 2000 240
40A, 63A,
80A, 100A
2000 1000 120

Porquê escolher a CHAC

Com mais de 30 anos de experiência em fabrico, mais de 1100 funcionários, mais de 100 milhões de postes
Com uma capacidade anual e um processo de produção automatizado 90%, a CHAC garante uma capacidade de produção estável e rigorosos
Controlo de qualidade para clientes OEM/ODM globais. O nosso sistema de fabrico interno suporta a longo prazo
cooperação para marcas elétricas, importadores e distribuidores.


30+

ANOS DE EXPERIÊNCIA

Especializado em fabrico de baixa tensão elétrica


1100+

FUNCIONÁRIOS

Equipa profissional garante qualidade e entrega estáveis


100M+

CAPACIDADE ANUAL DE POSTOS

Capacidade de produção em larga escala para satisfazer a procura global


90%

PRODUÇÃO AUTOMATIZADA

Automação avançada para alta eficiência e consistência

Linha de Montagem Automatizada

Linha de Montagem Automatizada

Laboratório de Ensaios

Laboratório de Ensaios

Injeção e Estampagem

Injeção e Estampagem

Inspeção de Qualidade

Inspeção de Qualidade

Certificação IEC
Certificação CE
Certificação CB
Certificação RoHS
Certificação ISO 14001

Um rigoroso sistema de controlo de qualidade garante que cada produto cumpre as normas globais.

O que podemos personalizar?

For PXL6a-100 projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.

Logótipo e Identidade Visual

Impressão de logótipos personalizados, marcação a laser e soluções de placas de identificação.

Logótipo e Identidade Visual

Embalagem
Personalização

Caixas, embalagens, etiquetas e manuais personalizados com cores.

Personalização de Embalagens

Elétrico
Personalização

Corrente, tensão, poder de corte, curva de disparo e outros
funções especiais.

Personalização Elétrica

Produto
Aparência

Cor da caixa, cor da pega e personalização da aparência.

Aparência do Produto

Certificação
Apoio

Os produtos cumprem os padrões internacionais e de mercado
requisitos.

Suporte de Certificação

Engenharia
Desenvolvimento

Avaliação do desenho, teste do protótipo e produção em massa.

Desenvolvimento de engenharia

Transferir

PDF

Disjuntor em Miniatura Série PXB6

Visão geral completa de componentes elétricos de baixa tensão e referência para seleção de produtos.

Transferir PDF

SUP

Precisa de Documentos Técnicos?

Contacte-nos para folhas de dados, certificados, desenhos, orientação de seleção ou suporte a projetos OEM/ODM.

Contacte-nos

PXL6a-100 Product FAQ

What is the PXL6a-100 used for?

The PXL6a-100 is specified for residual-current protection without overcurrent protection in AC 230/400V applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.

How does the PXL6a-100 work?

Its operating principle follows the documented function: residual-current protection without overcurrent protection. Use the exact model documentation for thresholds, timing, trip behaviour, terminals and test procedures.

How do I choose the PXL6a-100 rating and poles?

Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 2P / 4P; confirm neutral, polarity, conductors and isolation requirements.

What safety limitation applies to the PXL6a-100?

Do not treat the PXL6a-100 as a universal substitute for another device. Confirm 30mA, 100mA or 300mA options, the system voltage, fault or leakage conditions and any separate upstream protection before selection.

Can the PXL6a-100 be used in another circuit type?

Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.

How should the PXL6a-100 be installed and tested?

Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.

Confirm the Right PXL6a-100 Configuration

Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.

Pedir um orçamento