Bộ ngắt mạch nhỏ PXB6-63 L/T

Phần PXB6-63 L/T miniature circuit breaker provides overload and short-circuit protection within the published 6A–63A range. Its verified product data lists 4.5kA Icu = Ics, 1P / 2P / 3P / 4P and B / C / D. Final selection must match the conductor, load, prospective fault current, installation system and applicable local rules.

Người Ba Lan:
1P / 2P / 3P / 4P
Định mức dòng điện:
6A–63A
Đánh giá điện:
Điện áp cách điện định mức 500 V (Ui)
Tần suất:
50/60Hz
Phá vỡ dữ liệu:
4.5kA Icu = Ics
Loại chuyến đi / Loại chất thải:
B/C/D
Tiêu chuẩn
IEC 60898-1; GB/T 10963.1
Lắp đặt:
Tham khảo trung tâm đầu cuối 45mm

Giới thiệu sản phẩm

PXB6-63 L/T is a 4.5kA Icu = Ics miniature circuit breaker covering 6A–63A. It is available with 1P / 2P / 3P / 4P and B / C / D trip options as stated in the product data.

The model data references IEC 60898-1; GB/T 10963.1 and lists CCC certification. Standards, certification scope and technical documents must be confirmed for the ordered configuration and destination market.

Tính năng chính

  • Published current range: 6A–63A.
  • Pole configuration: 1P / 2P / 3P / 4P.
  • Lựa chọn chuyến đi / bảo vệ: B / C / D.
  • Short-circuit data: 4.5kA Icu = Ics.
  • Electrical reference: 500V rated insulation voltage (Ui), 50/60Hz.
  • Dữ liệu tuổi thọ: ≥10.000 lần vận hành cơ học và ≥4.000 lần vận hành điện.
  • Additional verified data: 4kV Uimp; IP20; conductor reference up to 16mm².

Các ứng dụng điển hình

Nó được thiết kế cho các mạch phân phối AC, trong đó cấp dòng điện được chọn, đường cong dòng điện, bố trí cực và công suất ngắt phù hợp với nghiên cứu về dây dẫn và hệ thống. Các bối cảnh dự án điển hình bao gồm phân phối cuối cấp trong khu dân cư, thương mại và công nghiệp nhẹ; sự phù hợp phụ thuộc vào mạch thực tế chứ không chỉ dựa vào nhãn hiệu ứng dụng.

Hướng dẫn đăng ký và tuyển chọn

Hãy sử dụng các giá trị cụ thể cho từng sản phẩm dưới đây làm danh sách lựa chọn, sau đó xác nhận lại toàn bộ thiết kế mạch. Các đánh giá về sản phẩm không thay thế cho việc nghiên cứu về dòng điện quá tải, tính toán dây dẫn, đánh giá phối hợp hoặc các quy tắc lắp đặt áp dụng.

Điểm lựa chọn PXB6-63 L/T option Những gì dự án phải xác nhận
Độ dòng định mức 6A–63A Điều phối với thông số thiết kế hiện tại, công suất dây dẫn, nhiệt độ môi trường xung quanh và nhóm hóa
Đường cong chuyến đi B/C/D Chọn đáp ứng dòng tải và hiệu suất giải quyết sự cố cần thiết, không chỉ dựa vào dòng điện
Khả năng phá vỡ 4.5kA Icu = Ics Xác nhận so với dòng điện ngắn mạch dự kiến tại điểm lắp đặt
Sắp xếp cột 1P / 2P / 3P / 4P Hệ thống cung cấp trận đấu và các quy tắc chuyển đổi hoặc cách ly tại địa phương
Giao diện cài đặt Tham khảo trung tâm đầu cuối 45mm Kiểm tra sự tương thích của vỏ bọc, ray/cơ sở, tiếp điểm và dây dẫn

Giới hạn khả năng chịu tải

4.5kA Icu = Ics is the published product value. Confirm the prospective short-circuit current at the installation point.

Mức độ lỗiViệc lựa chọn dự án

Hành vi di chuyển và tải trọng

B/C/D là lựa chọn bảo vệ/điểm truy cập có sẵn. Kết hợp chúng để đáp ứng tải điện áp cao và yêu cầu ngắt kết nối.

Đầu vào tảiViệc lựa chọn dự án

Cấu hình cực

Available arrangement: 1P / 2P / 3P / 4P. Confirm which conductors must be switched and protected under local rules.

Sơ đồ mạchViệc lựa chọn dự án

MCB hoặc RCBO

Thiết bị MCB không thay thế cho hệ thống bảo vệ dòng điện còn lại khi cần thiết phải sử dụng RCD hoặc RCBO.

Phạm vi bảo vệViệc lựa chọn dự án

Hướng dẫn đặt hàng

  1. Specify the exact model: PXB6-63 L/T.
  2. State the required current rating within 6A–63A.
  3. Confirm pole arrangement: 1P / 2P / 3P / 4P.
  4. Xác nhận lựa chọn chuyến đi hoặc bảo vệ: B / C / D.
  5. Cung cấp điện áp hệ thống, mức độ lỗi dự kiến, thị trường đích, số lượng và bất kỳ yêu cầu tài liệu nào.

Kiểm tra lắp đặt và phối hợp

  • Kiểm tra vật liệu dẫn và hình dạng của đường dẫn so với tính toán mạch và phạm vi đầu nối được công bố.
  • Xác nhận rằng dòng điện ngắn mạch dự kiến không vượt quá cấp điện được quy định.
  • Kiểm tra sự phối hợp giữa các phần trên và dưới, nhiệt độ của thùng chứa, cách bố trí, độ cao và khoảng cách cần thiết.
  • Việc lắp đặt, cách ly, thử nghiệm và bảo trì phải được thực hiện bởi nhân viên có trình độ chuyên môn theo quy định hiện hành.

Tên loại

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T

Các đường cong khi va chạm

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T

Kích thước (mm)

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T

Đặc điểm kỹ thuật

Tham số
Rated Insulation Voltage (Ui) 500V
Rated Impulse Withstand Voltage (Uimp) 4000V
Rated Current (In) 6, 10, 16, 20, 25, 32, 40, 50, 63
Tần số được đánh giá 50Hz / 60Hz
Số lượng người Ba Lan 1P, 2P, 3P, 4P
Rated Short-Circuit Breaking Capacity (Icu = Ics) 4500A
Mechanical Life ≥10000
Electrical Life ≥4000
Tripping Curves B, C, D
Terminal Center Distance 45mm
Protection Class IP20
Standard IEC60898-1, GB/T10963.1
Chứng nhận CCC

Tripping Characteristics (Reference Temperature: 30°C)

Item Tripping Curve Test Current (A) Initial Status Time limit for tripping or non-tripping Expected result Remarks
a B, C, D 1.13In Cold t ≤ 1h Non-tripping Current smoothly rises to specified value within 5s
b B, C, D 1.45In Following item a test t < 1h Tripping
c B, C, D 2.55In Cold 1s < t < 60s (In ≤ 32A)
1s < t < 120s (In > 32A)
Tripping
d B 3In Cold t ≤ 0.1s Non-tripping Switch on the power supply by closing the auxiliary switch
C 5In
D 10In
e B 5In Cold t < 0.1s Tripping Switch on the power supply by closing the auxiliary switch
C 10In
D 20In

Note: The term “cold” means that the test is carried out at a reference calibration temperature without load before the test.

Conductor requirements and cross section

Copper cross-section(mm2) Rated current In(A)
1 In≤6
1.5 6<In≤13
2.5 13<In≤20
4 20<In≤25
6 25<In≤32
10 32<In≤50
16 50<In≤63

Tại sao nên chọn CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.

Cqw2 Series Air Circuit Breaker product image
30+

NĂM KINH NGHIỆM

Chuyên sản xuất thiết bị điện hạ thế

Cqw2 Series Air Circuit Breaker product image
1100+

CÔNG NHÂN

Đội ngũ chuyên nghiệp đảm bảo chất lượng và giao hàng ổn định

Cqw2 Series Air Circuit Breaker product image
100 triệu người

Sức chứa hàng năm của các cột

Năng lực sản xuất quy mô lớn để đáp ứng nhu cầu toàn cầu

Cqw2 Series Air Circuit Breaker product image
90%

SẢN XUẤT TỰ ĐỘNG

Tự động hóa nâng cao cho hiệu quả cao và tính nhất quán

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T

Dây chuyền lắp ráp tự động

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T

Phòng thí nghiệm kiểm nghiệm

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T

Xay và dập

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T

Kiểm tra chất lượng

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T
Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T
Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T
Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T
Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T

Strict quality control system ensures every product meets global standards.

Chúng tôi có thể tùy chỉnh những gì?

For PXB6-63 L/T projects, CHAC can review private-label marking, packaging, appearance, available electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, MOQ and project feasibility.

Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Logo & Thương hiệu

Private-label marking and nameplate options are subject to artwork review and sample approval.

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Gói bao bì
Tùy chỉnh

Cartons, labels and manuals can be prepared for the approved order specification and destination market.

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Điện
Tùy chỉnh

Select from the published 6A–63A, 1P / 2P / 3P / 4P and B / C / D options; non-standard requests require technical evaluation.

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Sản phẩm
Vẻ ngoài

Appearance options can be reviewed subject to tooling, MOQ, marking requirements and technical feasibility.

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Chứng nhận
Hỗ trợ

Datasheets, drawings and verified certificate information are supplied for the applicable approved configuration.

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Kỹ thuật
Phát triển

Project support may include drawing review, sample evaluation, testing and production planning, subject to technical approval.

Hình ảnh sản phẩm cầu dao điện tử PXB6-63 L/T

Tải xuống

PDF

Bộ ngắt mạch nhỏ dòng PXB6

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Cần tài liệu kỹ thuật?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Liên hệ với chúng tôi

PXB6-63 L/T Product FAQ

What is an MCB trip curve?

It describes the time-current response and instantaneous magnetic-trip behavior. PXB6-63 L/T offers B, C and D curves for different inrush and fault-clearing requirements.

Which curve is best for the PXB6-63 L/T?

No curve is universally best. B generally suits lower inrush, C moderate inrush and D higher inrush, provided the available fault current can still achieve the required disconnection.

When should the PXB6-63 L/T use a C curve?

C curve is commonly evaluated for circuits with moderate starting current. Confirm the real load profile, conductor protection and fault-loop conditions before selection.

Will a 20A breaker trip exactly at 20A?

Not instantaneously. Thermal trip time depends on how far and how long current exceeds the rating, along with reference temperature and product characteristics.

Does the 80% rule apply to every circuit breaker?

No. The phrase is associated with particular market rules and applications; it should not be treated as a universal IEC requirement. Follow the governing installation standard and circuit calculation.

What is the 125% rule in electrical design?

It commonly describes market-specific treatment of continuous loads or conductor sizing. Apply only the rules that govern the project and do not use a fixed percentage as a substitute for verified PXB6-63 L/T data.

Confirm the Right PXB6-63 L/T Configuration

Send your current rating, pole arrangement, trip option, system voltage, prospective fault level, destination market and quantity. CHAC will review the request against the published product range.

Yêu cầu báo giá