{"id":6837,"date":"2026-11-16T00:00:00","date_gmt":"2026-11-16T00:00:00","guid":{"rendered":"https:\/\/chac-electric.com\/?p=6837"},"modified":"2026-11-13T08:28:28","modified_gmt":"2026-11-13T08:28:28","slug":"kich-thuoc-lo-dien","status":"publish","type":"post","link":"https:\/\/chac-electric.com\/vi\/blog\/electrical-knockout-dimensions\/","title":{"rendered":"K\u00edch th\u01b0\u1edbc l\u1ed7 \u0111\u1ee5c \u0111i\u1ec7n: K\u00edch th\u01b0\u1edbc l\u1ed7 v\u00e0 ki\u1ec3m tra l\u1eafp \u0111\u1eb7t"},"content":{"rendered":"<article>\n<p>M\u1ed9t nh\u00e0 mua h\u00e0ng b\u1ea3ng \u0111i\u1ec1u khi\u1ec3n \u0111\u1eb7t mua m\u1ed9t \u0111\u1ea7u n\u1ed1i \u0111\u01b0\u1ee3c ghi l\u00e0 1\/2 inch cho m\u1ed9t l\u1ed7 tr\u00ean v\u1ecf b\u1ecdc c\u00f3 k\u00edch th\u01b0\u1edbc \u0111o \u0111\u01b0\u1ee3c kho\u1ea3ng 22 mm. Ban \u0111\u1ea7u, c\u00e1c nh\u00e3n d\u00e1n c\u00f3 v\u1ebb kh\u00f4ng th\u1ed1ng nh\u1ea5t, v\u00ec v\u1eady \u0111\u01a1n h\u00e0ng b\u1ecb tr\u00ec ho\u00e3n trong khi ai \u0111\u00f3 t\u00ecm ki\u1ebfm m\u1ed9t l\u1ed7 nh\u1ecf h\u01a1n. S\u1ef1 nh\u1ea7m l\u1eabn mang t\u00ednh minh h\u1ecda n\u00e0y xu\u1ea5t ph\u00e1t t\u1eeb vi\u1ec7c so s\u00e1nh k\u00fd hi\u1ec7u ng\u00e0nh \u0111\u01b0\u1eddng \u1ed1ng d\u1eabn v\u1edbi \u0111\u01b0\u1eddng k\u00ednh th\u1ef1c t\u1ebf c\u1ee7a l\u1ed7.<\/p>\n<p><strong>T\u00f3m t\u1eaft:<\/strong> <strong>K\u00edch th\u01b0\u1edbc l\u1ed7 \u0111i\u1ec7n<\/strong> kh\u00f4ng gi\u1ed1ng v\u1edbi c\u00e1c k\u00edch th\u01b0\u1edbc \u1ed1ng lu\u1ed3n d\u00e2y ti\u00eau chu\u1ea9n. M\u1ed9t k\u00edch th\u01b0\u1edbc \u1ed1ng lu\u1ed3n d\u00e2y ph\u1ed5 bi\u1ebfn lo\u1ea1i 1\/2-inch c\u00f3 \u0111\u01b0\u1eddng k\u00ednh kho\u1ea3ng 7\/8 inch, ho\u1eb7c 22.2 mm. H\u00e3y s\u1eed d\u1ee5ng k\u00edch th\u01b0\u1edbc l\u1ed7 y\u00eau c\u1ea7u c\u1ee7a nh\u00e0 s\u1ea3n xu\u1ea5t ph\u1ee5 ki\u1ec7n v\u00e0 \u0111\u1ed9 d\u00e0y b\u1ea3ng \u0111i\u1ec1u khi\u1ec3n cho ph\u00e9p l\u00e0m ti\u00eau ch\u00ed l\u1ef1a ch\u1ecdn cu\u1ed1i c\u00f9ng; b\u1ea3ng k\u00edch th\u01b0\u1edbc danh ngh\u0129a ch\u1ec9 l\u00e0 \u0111i\u1ec3m kh\u1edfi \u0111\u1ea7u, kh\u00f4ng ph\u1ea3i dung sai gia c\u00f4ng.<\/p>\n<h2>T\u1ea1i sao k\u00edch th\u01b0\u1edbc \u1ed1ng lu\u1ed3n d\u00e2y \u0111i\u1ec7n danh \u0111\u1ecbnh l\u1ea1i kh\u00e1c v\u1edbi \u0111\u01b0\u1eddng k\u00ednh l\u1ed7 \u0111\u1ee5c th\u1ef1c t\u1ebf?<\/h2>\n<p>K\u00edch th\u01b0\u1edbc ti\u00eau chu\u1ea9n c\u1ee7a \u1ed1ng lu\u1ed3n d\u00e2y l\u00e0 m\u1ed9t quy \u01b0\u1edbc \u0111\u1eb7t t\u00ean \u0111\u01b0\u1ee3c chu\u1ea9n h\u00f3a. N\u00f3 kh\u00f4ng tr\u1ef1c ti\u1ebfp ch\u1ec9 ra \u0111\u01b0\u1eddng k\u00ednh ngo\u00e0i c\u1ee7a \u1ed1ng, \u0111\u01b0\u1eddng k\u00ednh ngo\u00e0i c\u1ee7a ren \u0111\u1ea7u n\u1ed1i ho\u1eb7c k\u00edch th\u01b0\u1edbc l\u1ed7 c\u1ea7n kho\u00e9t tr\u00ean th\u00e0nh v\u1ecf t\u1ee7. C\u00e1c k\u00edch th\u01b0\u1edbc n\u00e0y ph\u1ee5c v\u1ee5 nh\u1eefng m\u1ee5c \u0111\u00edch kh\u00e1c nhau v\u00e0 ph\u1ea3i \u0111\u01b0\u1ee3c so s\u00e1nh d\u1ef1a tr\u00ean c\u00e1c th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt ri\u00eang c\u1ee7a ch\u00fang.<\/p>\n<p>C\u00e1c m\u0169i \u0111\u1ee5c c\u0169ng c\u00f3 th\u1ec3 s\u1eed d\u1ee5ng c\u00e1c quy \u01b0\u1edbc \u0111\u1eb7t t\u00ean kh\u00e1c nhau. M\u1ed9t m\u0169i \u0111\u1ee5c theo c\u1ee1 \u1ed1ng \u0111\u01b0\u1ee3c \u0111\u00e1nh d\u1ea5u theo k\u00edch th\u01b0\u1edbc ren ti\u00eau chu\u1ea9n, trong khi m\u1ed9t m\u0169i \u0111\u1ee5c theo k\u00edch th\u01b0\u1edbc th\u1ef1c t\u1ebf \u0111\u01b0\u1ee3c \u0111\u00e1nh d\u1ea5u theo k\u00edch th\u01b0\u1edbc l\u1ed7 m\u00e0 n\u00f3 t\u1ea1o ra. Do \u0111\u00f3, m\u1ed9t d\u1ee5ng c\u1ee5 \u0111\u01b0\u1ee3c ghi l\u00e0 3\/4 inch theo m\u1ed9t quy \u01b0\u1edbc kh\u00f4ng n\u00ean b\u1ecb cho r\u1eb1ng s\u1ebd t\u1ea1o ra c\u00f9ng m\u1ed9t l\u1ed7 nh\u01b0 m\u1ed9t d\u1ee5ng c\u1ee5 \u0111\u01b0\u1ee3c ghi l\u00e0 3\/4 inch theo quy \u01b0\u1edbc kia.<\/p>\n<table>\n<thead>\n<tr>\n<th>T\u00ean th\u01b0\u01a1ng m\u1ea1i th\u00f4ng th\u01b0\u1eddng c\u1ee7a \u1ed1ng d\u1eabn<\/th>\n<th>Tham chi\u1ebfu m\u1edf danh ngh\u0129a<\/th>\n<th>T\u01b0\u01a1ng \u0111\u01b0\u01a1ng m\u00e9t x\u1ea5p x\u1ec9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1\/2 inch<\/td>\n<td>7\/8 inch<\/td>\n<td>22.2 mm<\/td>\n<\/tr>\n<tr>\n<td>3\/4 inch<\/td>\n<td>1-1\/8 inch<\/td>\n<td>28.6 mm<\/td>\n<\/tr>\n<tr>\n<td>1 inch<\/td>\n<td>1-3\/8 inches<\/td>\n<td>34.9 mm<\/td>\n<\/tr>\n<tr>\n<td>1-1\/4 inches<\/td>\n<td>1-3\/4 inches<\/td>\n<td>44.5 mm<\/td>\n<\/tr>\n<tr>\n<td>1-1\/2 inches<\/td>\n<td>2 inches<\/td>\n<td>50.8 mm<\/td>\n<\/tr>\n<tr>\n<td>2 inches<\/td>\n<td>2-1\/2 inches<\/td>\n<td>63.5 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These are common nominal reference sizes for familiar conduit-entry applications. Actual punch cutting diameters, connector instructions and enclosure specifications may differ slightly. Do not use the rounded metric column as an instruction to drill a precision hole or as proof that a metric cable gland will fit.<\/p>\n<p>For example, an M20 gland and a 1\/2-inch conduit connector belong to different dimensional systems. A similar-looking mounting end does not establish interchangeability. Check the specified clearance hole, thread form, sealing surface and locknut rather than comparing names or approximate diameters alone.<\/p>\n<figure style=\"margin:1.5em auto;max-width:100%;\"><img src=\"https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/11\/electrical-knockout-dimensions-detail.webp\" alt=\"Trade size is not the hole diameter \u2014 Electrical Knockout Dimensions\" width=\"1672\" height=\"941\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;height:auto;\" \/><\/figure>\n<h2>How to check whether a connector fits an existing knockout<\/h2>\n<p>Measure the clear opening in more than one direction after confirming the equipment is safe to work on. An irregular or damaged edge can produce misleading readings. Record the measured range, wall thickness and any remaining concentric rings, then compare those observations with the connector\u2019s installation instructions.<\/p>\n<p>The connector must pass through the opening while allowing its shoulder, sealing washer and locknut to seat correctly where applicable. Adequate thread engagement matters. A fitting that can be pushed through a hole is not necessarily suitable for the panel thickness or able to maintain the required enclosure protection.<\/p>\n<p>Also check internal clearance. The body of a connector, its locknut and the required cable bend can interfere with terminals, barriers or neighboring fittings. A hole that is correctly sized but poorly located can still force an enclosure redesign. Include these clearances in the entry schedule before releasing a drawing for manufacture.<\/p>\n<table>\n<thead>\n<tr>\n<th>Ki\u1ec3m tra<\/th>\n<th>Record or obtain<\/th>\n<th>L\u00fd do<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Opening<\/td>\n<td>Measured diameter, shape and edge condition<\/td>\n<td>Confirm the actual hole rather than the trade label<\/td>\n<\/tr>\n<tr>\n<td>Enclosure wall<\/td>\n<td>Material, thickness and available flat area<\/td>\n<td>Check clamping, sealing and tool suitability<\/td>\n<\/tr>\n<tr>\n<td>Fitting<\/td>\n<td>Required hole, mounting thread and panel-thickness range<\/td>\n<td>Establish dimensional compatibility<\/td>\n<\/tr>\n<tr>\n<td>Inside clearance<\/td>\n<td>Locknut, body and conductor-routing space<\/td>\n<td>Avoid interference with electrical components<\/td>\n<\/tr>\n<tr>\n<td>M\u00f4i tr\u01b0\u1eddng<\/td>\n<td>Required ingress protection and location conditions<\/td>\n<td>Select a fitting and sealing arrangement for the use<\/td>\n<\/tr>\n<tr>\n<td>Bonding<\/td>\n<td>Applicable grounding and bonding requirements<\/td>\n<td>Do not infer electrical continuity from mechanical fit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure style=\"margin:1.5em auto;max-width:100%;\"><img src=\"https:\/\/chac-electric.com\/wp-content\/uploads\/2026\/11\/electrical-knockout-dimensions-explanation.webp\" alt=\"Measure the opening and check the fitting \u2014 Electrical Knockout Dimensions\" width=\"1672\" height=\"941\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;height:auto;\" \/><\/figure>\n<h2>Choose a knockout punch by its finished hole size and material capacity<\/h2>\n<p>Choose the finished opening first, then choose the punch. Confirm the tool\u2019s actual hole diameter, material capability and maximum sheet thickness. A punch suitable for one metal or thickness is not automatically suitable for another, even when its nominal size is correct.<\/p>\n<p>Use the punch, die and draw stud as the manufacturer specifies. Mixing parts from unrelated sets can change alignment or loading. The pilot hole and available working space also matter; a nominally suitable tool may not physically fit beside a folded enclosure edge or an existing component.<\/p>\n<p>Where the design calls for three 1\/2-inch trade-size entries, state the required finished openings and center locations on the manufacturing drawing. Do not ask a fabricator to interpret an informal note such as three half-inch holes. That note can reasonably be read as three holes with an actual diameter of 12.7 mm.<\/p>\n<p>For metric conversion, multiply inches by exactly 25.4. Thus 7\/8 inch equals 0.875 \u00d7 25.4 = 22.225 mm. Rounding to 22.2 mm is useful for identification, but tolerances and the selected cutting tool still control production. The unit conversion itself does not add manufacturing clearance.<\/p>\n<h2>Check concentric knockout integrity and close unused openings correctly<\/h2>\n<p><strong>Concentric knockouts<\/strong> provide more than one removable ring. Remove only the ring needed for the selected fitting, using the enclosure manufacturer\u2019s instructions. Damage to an adjacent ring can leave an oversized or irregular opening and may affect mechanical retention or bonding.<\/p>\n<p>Grounding and bonding requirements depend on the installation and connection arrangement. Some applications require additional provisions where concentric or eccentric knockouts are involved. An electrical contractor should check the adopted code and listed assembly instructions rather than assuming every locknut arrangement is equivalent.<\/p>\n<p>Close unused openings with purpose-made closures suited to the hole and environment. An indoor snap-in plug is not automatically appropriate for a wet-location enclosure. Tape, improvised plates and loose hardware do not establish that the original enclosure protection has been maintained.<\/p>\n<p>US workplace rules, including 29 CFR 1910.303 for covered installations, address unused openings and mechanical execution. Product standards and installation rules have separate roles: a connector standard describes its scope, while the project\u2019s adopted electrical rules determine how the installed arrangement must be used.<\/p>\n<h2>Specify enclosure openings and fittings before ordering the box<\/h2>\n<p>A complete request identifies the box model, wall material and thickness, entry locations, fitting part numbers, environmental requirements and unused-opening closures. Specify whether openings are factory-provided, field-made or supplied as removable knockouts. This prevents a quotation for a blank enclosure from being compared with one that includes machining.<\/p>\n<p>CHAC <a href=\"https:\/\/chac-electric.com\/vi\/product\/giai-phap-ket-noi-hop-phan-phoi-dong-cqmg03\/\">CQMG03 distribution junction box range<\/a> provides a relevant enclosure starting point. Confirm the drawing and entry details for the exact ordered variant; the general dimensions in this guide do not establish the knockout sizes of every CHAC box.<\/p>\n<p>Check cable and conductor size separately from enclosure entry size. The <a href=\"https:\/\/chac-electric.com\/vi\/may-tinh-dien-tu\/kich-thuoc-cap\/\">cable sizing tool<\/a> can support an initial electrical calculation, but cable outside diameter and gland fit still require the cable and fitting data sheets. A conductor\u2019s cross-sectional area is not the diameter of the complete cable.<\/p>\n<p>For repeat orders, retain the approved entry drawing and revision with the purchase specification. A small undocumented change in wall thickness or fitting family can cause assembly problems across an otherwise identical batch. That record is often more useful than storing a photograph of a finished box without dimensions.<\/p>\n<h2>Common questions about electrical knockout sizes<\/h2>\n<h3>What is the actual diameter of a 1\/2-inch knockout?<\/h3>\n<p>A common nominal opening for a 1\/2-inch conduit trade-size fitting is 7\/8 inch, approximately 22.2 mm. Check the selected fitting and punch data for the actual required diameter and tolerance. It is not a 12.7 mm hole.<\/p>\n<h3>What size hole is needed for a 3\/4-inch electrical knockout?<\/h3>\n<p>The common nominal reference is 1-1\/8 inches, approximately 28.6 mm. Actual tooling dimensions may vary slightly. Use the connector manufacturer\u2019s required opening for the final specification.<\/p>\n<h3>What knockout size is needed for 1-1\/4-inch EMT?<\/h3>\n<p>A common nominal entry reference is 1-3\/4 inches, approximately 44.5 mm, for the corresponding connector. The connector establishes the enclosure opening; do not size the hole directly from the EMT trade designation.<\/p>\n<h3>Why is conduit trade size different from knockout hole diameter?<\/h3>\n<p>Trade size names a conduit system size rather than the diameter of every associated component. The connector\u2019s mounting end needs its own opening. Conduit outside diameter, fitting thread and enclosure hole therefore require separate checks.<\/p>\n<h3>How do you convert electrical knockout dimensions from inches to millimeters?<\/h3>\n<p>Multiply the actual inch dimension by 25.4. Convert the hole diameter, not just the conduit trade-size label. Retain the specified tolerance instead of treating a rounded conversion as a fabrication dimension.<\/p>\n<h3>How do you choose a connector that fits an existing knockout?<\/h3>\n<p>Measure the opening and wall thickness, then check the connector\u2019s required hole and permitted mounting range. Confirm sealing, internal clearance and bonding requirements as well. Physical insertion alone does not establish an acceptable installation.<\/p>\n<h3>How should an unused electrical knockout opening be closed?<\/h3>\n<p>Use a purpose-made closure suitable for the opening and required enclosure protection. Follow the enclosure and closure instructions. Replace damaged arrangements rather than covering the opening with improvised material.<\/p>\n<h2>Tham kh\u1ea3o<\/h2>\n<ul>\n<li><a href=\"https:\/\/en.wikipedia.org\/wiki\/Knockout_punch\" rel=\"nofollow noopener\" target=\"_blank\">Knockout punch: conduit-size and dimensional-size naming<\/a><\/li>\n<li><a href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.303\" rel=\"nofollow noopener\" target=\"_blank\">29 CFR 1910.303: electrical installation and unused openings<\/a><\/li>\n<li><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" rel=\"nofollow noopener\" target=\"_blank\">NFPA 70: installation-code edition information<\/a><\/li>\n<\/ul>\n<p>The best-fitting entry is the one defined by the complete connector and enclosure arrangement. <a href=\"https:\/\/chac-electric.com\/vi\/hay-lien-he-voi-chung-toi\/\">Send CHAC your enclosure and entry requirements<\/a> with fitting details and a dimensioned drawing.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>So s\u00e1nh c\u00e1c k\u00edch th\u01b0\u1edbc \u1ed1ng lu\u1ed3n d\u00e2y v\u1edbi c\u00e1c l\u1ed7 \u0111\u1ee5c th\u1ef1c t\u1ebf, chuy\u1ec3n \u0111\u1ed5i \u0111\u01a1n v\u1ecb t\u1eeb inch sang milim\u00e9t, v\u00e0 ki\u1ec3m tra c\u00e1c \u0111\u1ea7u n\u1ed1i, d\u1ee5ng c\u1ee5 \u0111\u1ee5c l\u1ed7 v\u00e0 n\u00fat b\u1ecbt tr\u01b0\u1edbc khi \u0111\u1eb7t h\u00e0ng.<\/p>","protected":false},"author":1,"featured_media":6924,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-6837","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"_links":{"self":[{"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/posts\/6837","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/comments?post=6837"}],"version-history":[{"count":2,"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/posts\/6837\/revisions"}],"predecessor-version":[{"id":6869,"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/posts\/6837\/revisions\/6869"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/media\/6924"}],"wp:attachment":[{"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/media?parent=6837"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/categories?post=6837"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chac-electric.com\/vi\/wp-json\/wp\/v2\/tags?post=6837"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}