جهاز تيار متبقي للحماية الكهرومغناطيسية من سلسلة CQL14

ال CQL14 is specified for residual-current protection without overcurrent protection. Select it using the published voltage, current, pole and protection data, then confirm conductor coordination, fault conditions, enclosure requirements and local installation rules.

بولنديون
2P / 4P
التيار المقنن
See technical table
الجهد المقنن
AC 230/400V
Primary Function:
residual-current protection without overcurrent protection
Selection Data:
30mA, 100mA or 300mA options
قياسي
IEC 61008-1 family references

Product Overview

CQL14 is a electromagnetic residual current device for AC 230/400V applications. It is intended for residential, commercial and industrial circuits where a separate overcurrent device is coordinated; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.

residual-current protection without overcurrent protection is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.

Key Features

  • Published pole options: 2P / 4P.
  • Published electrical context: AC 230/400V.
  • Primary function: residual-current protection without overcurrent protection.
  • Selection reference: 30mA, 100mA or 300mA options.
  • Applicable standard reference: IEC 61008-1 family references.
  • Final selection must use the exact model table, drawings and installation instructions.

Typical Applications

residential, commercial and industrial circuits where a separate overcurrent device is coordinated. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.

Applications and Selection Guide

Use the verified CQL14 records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.

Selection point CQL14 reference What the project must confirm
Rated current Use the exact model table Design current, conductor capacity, ambient and grouping
Voltage and frequency AC 230/400V Supply system and equipment rating
أقطاب 2P / 4P Conductors to be switched, protected or isolated
Protection / control residual-current protection without overcurrent protection Required function and adjacent-device coordination
Fault / residual data 30mA, 100mA or 300mA options Prospective short-circuit or leakage conditions

RCCB vs RCBO

An RCCB addresses residual-current protection; an RCBO combines residual-current and overcurrent functions. Choose the architecture required by the protection study.

Protection Function
Compare RCBO Options →

Model-Specific Ratings

Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.

Verified Data
View Technical Support →

Installation and Coordination

Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.

Engineering Check
Discuss a Configuration →

Ordering Information

State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.

Project Inputs
Send Project Details →

Ordering Guide

  1. State the exact model: CQL14.
  2. Provide rated current and voltage from the published technical table.
  3. Confirm poles and the required protection, isolation or control function.
  4. Provide application, expected fault/leakage conditions, destination market and quantity.
  5. List accessory, terminal, documentation and approved marking or packaging requirements.

Installation and Coordination Checks

  • Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
  • Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
  • Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
  • Installation, testing and maintenance must be completed by qualified personnel under applicable rules.

تعيين النوع

الأبعاد (مم)

المواصفات الفنية

معامل Specification
Rated Voltage 230V AC (1P+N); 400V AC (3P+N)
Rated Current (A) 25A, 40A, 63A, 80A, 100A
Rated Residual Operating Current 0.03A, 0.1A, 0.3A
Rated Residual Non-Operating Current 0.5I△n
Type of Residual Current (with DC component) AC type, A type (In=25, 40, 63A)
Number of Poles 1P+N, 3P+N
Rated Conditional Short-Circuit Current 6000A
Rated Conditional Residual Short-Circuit Current 6000A
Rated Making and Breaking Capacity 500A (In=25, 40A); 10In (63, 80, 100A)
Rated Residual Making and Breaking Capacity 500A (In=25, 40A); 10In (63, 80, 100A)
Tightening Torque (2.5 ~ 3.0) N·m
Protection Class IP20
Pollution Degree 2
Installation Category
معايير GB 16916.1, IEC61008-1

Operating time (for residual current devices)

In (A) IΔn (A) Breaking time when the residual current equals the following values(s)
IΔn 2IΔn 5IΔn 5A、10A、20A、50A、100A、200A IΔt
25~100A 0.03、0.1、0.3 0.1 0.05 0.04 0.04 0.04

Mechanical and electrical endurance

In (A) Number of operating cycles Operating frequency (cycles per hour)
Number of on-load operating cycles Number of no-load operating cycles
25A 2000 4000 240
40A, 63A, 80A, 100A 2000 4000 120

لماذا تختار CHAC

مع خبرة تصنيع تزيد عن 30 عامًا، وأكثر من 1100 موظف، وأكثر من 100 مليون عمود
بفضل طاقتها الإنتاجية السنوية ونظام الإنتاج الآلي 90%، توفر شركة CHAC طاقة إنتاجية مستقرة ومعايير صارمة
مراقبة الجودة لعملاء OEM/ODM العالميين. يدعم نظام التصنيع الداخلي الخاص بنا على المدى الطويل
تعاون مع العلامات التجارية الكهربائية والمستوردين والموزعين.


30+

سنوات الخبرة

متخصص في تصنيع المعدات الكهربائية منخفضة الجهد


1100+

الموظفين

فريق محترف يضمن جودة ثابتة والتسليم


١٠٠ مليون+

السعة السنوية للأعمدة

قدرة إنتاجية واسعة النطاق لتلبية الطلب العالمي


90%

الإنتاج الآلي

الأتمتة المتقدمة لتحقيق كفاءة واتساق عاليين

خط التجميع الآلي

خط التجميع الآلي

مختبر اختبار

مختبر اختبار

حقن وختم

حقن وختم

فحص الجودة

فحص الجودة

شهادة IEC
شهادة CE
شهادة CB
شهادة RoHS
شهادة الآيزو 14001

نظام صارم لمراقبة الجودة يضمن أن كل منتج يلبي المعايير العالمية.

ما الذي يمكننا تخصيصه؟

For CQL14 projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.

الشعار والعلامة التجارية

طباعة شعارات مخصصة، نقش ليزر، وحلول لوحات الأسماء.

الشعار والعلامة التجارية

تعبئة وتغليف
تخصيص

صناديق وأغلفة وعلب وملصقات وكتيبات بألوان مخصصة.

تخصيص التعبئة والتغليف

كهربائي
تخصيص

التيار، الجهد، قدرة الفصل، منحنى الفصل، وغيرها
دوال خاصة.

تخصيص كهربائي

منتج
مظهر

تخصيص لون الهيكل، ولون المقبض، والمظهر.

مظهر المنتج

شهادة
دعم

المنتجات تتوافق مع المعايير الدولية والسوق
المتطلبات.

دعم الشهادات

الهندسة
تطوير

تقييم الرسم، اختبار النموذج الأولي، والإنتاج الضخم.

التطوير الهندسي

تنزيل

ملف PDF

منتجات أخرى

نظرة عامة كاملة على مكونات كهربائية منخفضة الجهد ومرجع لاختيار المنتج.

تحميل ملف PDF

سوب

هل تحتاج إلى وثائق فنية؟

اتصل بنا للحصول على أوراق البيانات، والشهادات، والرسومات، وإرشادات الاختيار، أو دعم مشاريع OEM/ODM.

اتصل بنا

CQL14 Product FAQ

What is the CQL14 used for?

The CQL14 is specified for residual-current protection without overcurrent protection in AC 230/400V applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.

How does the CQL14 work?

Its operating principle follows the documented function: residual-current protection without overcurrent protection. Use the exact model documentation for thresholds, timing, trip behaviour, terminals and test procedures.

How do I choose the CQL14 rating and poles?

Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 2P / 4P; confirm neutral, polarity, conductors and isolation requirements.

What safety limitation applies to the CQL14?

Do not treat the CQL14 as a universal substitute for another device. Confirm 30mA, 100mA or 300mA options, the system voltage, fault or leakage conditions and any separate upstream protection before selection.

Can the CQL14 be used in another circuit type?

Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.

How should the CQL14 be installed and tested?

Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.

Confirm the Right CQL14 Configuration

Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.

Request a Quote