CQHD SERIES PV Combiner Box

ال CHAC CQHD PV DC combiner box combines photovoltaic string inputs with DC circuit-breaker protection. Choose from six input/output configurations to match your PV array layout, and confirm the voltage and current ratings for the selected model.

Input / Output Configurations:
1 in / 1 out; 2 in / 1 out; 3 in / 1 out; 2 in / 2 out; 4 in / 2 out; 6 in / 2 out
Maximum System Voltage:
500V / 1000V DC, depending on model
Maximum Output Current:
32A / 63A, depending on model
DC Breaker Rated Current:
16A / 32A / 45A, depending on model
Enclosure Material:
Polycarbonate (PC)
Enclosure Ratings:
IP65 / IK09
التثبيت:
Wall mounting
Standard Reference:
IEC/EN 60947-3

Product Application

  • IP65 DC string box is designed for 1/4 string PV system. For surge protection and over-load protection at solar DC side.

  • IP65 DC string box is designed for 2/3 string PV system. For surge protection and current protection at solar DC side.

  • IP65 DC string box is designed for 6 string PV system. For surge current protection at solar DC side.

DC Breaker

CQBD-63

  • IEC60947-2 PV&DC standard

  • Over-load, short circuit Protection

  • Non Polarity for easier wiring

DC Surge Arrester

EXS-T2-DC/2P/3P

  • Max Operation Voltage 1000V

  • Standard Compliance with IEC/EN 61643-31 Type2

  • Maximum Discharge Current 40 KA

DC Fuse

CQDF-32

  • LED indicator or without LED indicator

  • Rated Working Voltage 1000V

  • Fuse Link 10×38mm 16A

Technical Data

صندوق التجميع CQHD-1/1 PV

المواصفات
  CQHD-1/1 Wiring diagram
مدخل 1 strings
Output 1 strings
Max Voltage 500V 1000V
Rated Current of DC Breaker 16A 16A
Max Current Output ٣٢أ ٣٢أ
حَظِيرة
Material PC
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-9;L218*W200*H100mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
بيئة
Operating temperature -20℃ – +60℃
رطوبة 99%
Altitude 2000M
التثبيت Wall Mounting

صندوق الجمع CQHD-2/1 PV

المواصفات
  CQHD-2/1 Wiring diagram
مدخل 2 strings
Output 1 strings
Max Voltage 1000V
Rated Current of DC Breaker ٣٢أ
Max Current Output ٦٣ أمبير
حَظِيرة
Material  
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-13;L296*W230*H120mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
بيئة
Operating temperature -20℃ – +60℃
رطوبة 99%
Altitude 2000M
التثبيت Wall Mounting

صندوق التجمع CQHD-2/2 PV

المواصفات
  CQHD-2/2 Wiring diagram
مدخل 2 strings
Output 2 strings
Max Voltage 500V 1000V
Rated Current of DC Breaker 16A 16A
Max Current Output ٣٢أ ٣٢أ
حَظِيرة
Material PC
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-18;L386*W230*H120mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
بيئة
Operating temperature -20℃ – +60℃
رطوبة 99%
Altitude 2000M
التثبيت Wall Mounting

صندوق الجمع CQHD-3/1 PV

المواصفات
  CQHD-3/1 Wiring diagram
مدخل 3 strings
Output 1 strings
Max Voltage 500V 1000V
Rated Current of DC Breaker 45A 45A
Max Current Output ٦٣ أمبير ٦٣ أمبير
حَظِيرة
Material  
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-13:L296*W230*H120mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
بيئة
Operating temperature -20℃ – +60℃
رطوبة 99%
Altitude 2000M
التثبيت Wall Mounting

صندوق التجمع CQHD-4/2 PV

المواصفات
  CQHD-4/2 Wiring diagram
مدخل 4 strings
Output 2 strings
Max Voltage 500V 1000V
Rated Current of DC Breaker ٣٢أ ٣٢أ
Max Current Output ٦٣ أمبير ٦٣ أمبير
حَظِيرة
Material PC
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-26;L296*W390*H130mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
بيئة
Operating temperature -20℃ – +60℃
رطوبة 99%
Altitude 2000M
التثبيت Wall Mounting

صندوق الجمع CQHD-6/2 PV

المواصفات
  CQHD-6/2 Wiring diagram
مدخل 6 strings
Output 2 strings
Max Voltage 1000V
Rated Current of DC Breaker 45A
Max Current Output ٦٣ أمبير
حَظِيرة
Material PC
Degree of Protection IP65
Impacts IK09
Dimensions DXAT-26:L296*W390*H130mm
Input Cable Glands PG09,2.5-16
Output Cable Gland PG21,2.5-16
بيئة
Operating temperature -20℃ – +60℃
رطوبة 99%
Altitude 2000M
التثبيت Wall Mounting