ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector

Der ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector is a CHAC surge protection device for transient overvoltage protection. The page keeps the model-specific technical table and original product images so buyers can verify voltage, current, configuration, mounting and applicable standards before ordering. Final suitability depends on the complete circuit, installation method and destination-market rules.

Produktfamilie:
SPD
Hauptfunktion:
transient overvoltage protection
Typischer Kontext:
PV, building distribution and control panels
Technische Daten:
Siehe verifizierte Modell-Liste unten
Konfiguration:
Bestätigen Sie die genaue Modellvariante
Support:
Überprüfung von OEM/ODM erhältlich

Product Overview

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector is a surge protection device intended for transient overvoltage protection. The current product record identifies it for PV, building distribution and control panels. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.

Verified source summary: Dimensions(mm) Technical Specifications Parameter Rated voltage (max. continuous AC voltage) 275V or 385V Lightning impulse current (10/350) [limp] 7 kA Nominal discharge current (8/20) [In] 20 kA Maximum discharge current [Imax] 50 kA Voltage protection level [Up] ≤ 1.5 kV Follow current extinguishing capability at Uc 32A fuse will not be triggered at 2kA…255V Response time [t] ≤ 100 ns Max. backupfuse (L) 200A gL

Key Features

  • Product type: surge protection device.
  • Primary function: transient overvoltage protection.
  • Application context: PV, building distribution and control panels.
  • Model variants, dimensions and ratings remain in the preserved technical source.
  • Confirm installation method, environmental limits and local compliance before release.

Typische Anwendungen

Typical use can include PV, building distribution and control panels when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.

Applications and Selection Guide

Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.

Selection point ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector What the project must confirm
Anwendung SPD projects Confirm the actual system and environment
Selection basis transient overvoltage protection Use the exact model and technical table
Installation Follow the model instructions Check mounting, clearances and termination
Compliance Use the listed standard where applicable Verify edition, scope and destination rules
Adjacent product Evaluate the related CHAC family where function differs Do not substitute without engineering review

Funktion

transient overvoltage protection

Match the protection or switching function to the system.

View related guidance →

Configuration

Model-specific options

Confirm current, voltage, poles, terminals or accessories from the table.

View related guidance →

Installation

Mechanical and electrical fit

Check enclosure, mounting, wiring space and maintenance access.

View related guidance →

Project evidence

Documents and test records

Retain the approved drawing, technical sheet and commissioning record.

View related guidance →

Ordering Guide

  1. State the exact model and variant.
  2. Provide the system voltage, current, frequency and load or protection function.
  3. Confirm mounting, terminals, accessories, enclosure and environmental conditions.
  4. Share quantity, destination market and required technical documents.

Installation and Coordination Checks

  • Verify the model’s ratings and connection arrangement against the project drawings.
  • Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
  • Coordinate upstream and downstream protection or control devices where applicable.
  • Use qualified personnel for installation, testing, isolation and maintenance.

Dimensions(mm)

Exs T1T2 Ac Series Single Pole Pluggable Surge Protector product image

Technical Specifications

Parameter  
Rated voltage (max. continuous AC voltage) 275V or 385V
Lightning impulse current (10/350) [limp] 7 kA
Nominal discharge current (8/20) [In] 20 kA
Maximum discharge current [Imax] 50 kA
Voltage protection level [Up] ≤ 1.5 kV
Follow current extinguishing capability at Uc 32A fuse will not be triggered at 2kA…255V
Response time [t] ≤ 100 ns
Max. backupfuse (L) 200A gL/gG
Max. backupfuse (L-L’) 125A gL/gG
TOV voltage 355V/5sec
Operating temperature range (parallel wiring) -40℃ to +80℃
Operating temperature range (through wiring) -40℃ to +60℃
Terminal cross-sectional area 35 mm2 solid / 50 mm2 flexible
Mounting on 35mm DIN rail
Enclosure material Purple (module)/light gray (base) thermoplastic, UL94-V0
Dimension 2 modules
Type of remote signalling contact Switching contact
Switching capacity AC 250V/0.5A
Switching capacity DC 250V / 0.1A; 125V / 0.2A; 75V / 0.5A
Cross-sectional area for remote signalling contact Max. 1.5 mm2 solid/flexible
Standards IEC 61643-11; GB 18802.1; YD/T 1235.1
Zertifizierung CE, RoHS, ISO 9001, CQC,TUV

Warum CHAC wählen?

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.

Cqw2 Series Air Circuit Breaker product image
30+

JAHRE ERFAHRUNG

Specialisiert auf die Herstellung von Niederspannungselektronik

Cqw2 Series Air Circuit Breaker product image
1100+

ARBEITER

Das professionelle Team gewährleistet eine stabile Qualität und Lieferfähigkeit.

Cqw2 Series Air Circuit Breaker product image
100 Millionen+

JAHRESTERNE VON POLES

Großserienfertigung zur Deckung der weltweiten Nachfrage

Cqw2 Series Air Circuit Breaker product image
90%

AUTOMATISCHE PRODUZIERUNG

Erweiterte Automatisierung für hohe Effizienz und Konsistenz

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image

Automatisierte Montagelinie

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image

Testlabor

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image

Injektion und Stempeln

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image

Qualitätskontrolle

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image
ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image
ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image
ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image
ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image

Strict quality control system ensures every product meets global standards.

Was können wir anpassen?

We support customization across branding, packaging, product appearance,
electrical specifications, certification requirements and engineering development. Whether customers
need private label products, market-specific parameters or new product development, CHAC can provide
flexible solutions based on project requirements.

Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Logo & Branding

Kundenspezifische Logo-Bedruckung, Lasermarkierung und Namensschild-Lösungen.

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Verpackung
Anpassung

Kundenspezifische Farbkartons, Kartons, Etiketten und Handbücher.

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Elektrisch
Anpassung

Current, voltage, breaking capacity, trip curve and other
special functions.

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Produkt
Aussehen

Anpassung der Wohnungsfarbe, des Griffs und des Erscheinungsbildes.

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Zertifizierung
Support

Products comply with international standards and market
requirements.

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Ingenieurwesen
Entwicklung

Auswertung der Zeichnungen, Prototypentest und Massenfertigung.

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector product image

Herunterladen

PDF

CQB3-Serie Miniaturstromschutzschalter

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Kontaktieren Sie uns

ExS-T1T2-AC Product FAQ

What does the ExS-T1T2-AC SPD protect?

It is intended to limit transient overvoltage in the system stated by the product record. Confirm the AC or DC system, protection zone, discharge rating and backup protection for the selected variant.

How do I choose an SPD discharge rating?

Use the project's lightning and transient exposure, system arrangement and the device's published In, Imax or Iimp values. Do not select by nominal voltage alone.

Does an SPD replace a circuit breaker?

No. An SPD diverts transient energy, while a breaker or fuse provides overcurrent protection. The two devices must be coordinated.

What should be checked before installation?

Check voltage, wiring mode, earthing, backup fuse, lead length, enclosure and the manufacturer's connection diagram.

When should the module be replaced?

Use the status indicator and the product instructions. Investigate the cause of a fault indication before fitting a replacement module.

What documents can CHAC provide?

Request the applicable datasheet, wiring diagram, dimensions and verified compliance documents for the ordered configuration.

Confirm the Right ExS-T1T2-AC Configuration

Send the exact model, operating conditions, quantity, destination market and required documents. CHAC will review the request against the published product data.

Angebot anfordern