Interruptor automático miniatura CQB2-63

El interruptor automático en miniatura CQB2-63 is designed for overload and short-circuit protection in 230/400V AC final-distribution systems. It covers 6A to 63A, B, C and D tripping curves, and 1P, 1P+N, 2P, 3P, 3P+N and 4P configurations. Its rated short-circuit breaking capacity is 6kA, with Icn equal to Ics. The series is specified to IEC 60898-1 and the model page lists CCC certification. It gives distributors, panel builders and OEM buyers a clearly defined platform for residential, commercial and light-industrial distribution projects.

Polacos
1P / 1P+N / 2P / 3P / 3P+N / 4P
Corriente nominal:
6A–63A
Voltaje nominal
230/400V CA
Capacidad de ruptura:
6kA (Icn = Ics)
Curva de disparo
B / C / D
Estándar
IEC 60898-1
Certification:
CCC
Personalización
Product-specific OEM/ODM options

Descripción del producto

The CQB2-63 is a 6kA miniature circuit breaker for final-distribution circuits that require overload and short-circuit protection. It is rated for 230/400V AC at 50 or 60Hz and is available from 6A to 63A. Buyers can specify B, C or D tripping characteristics and choose 1P, 1P+N, 2P, 3P, 3P+N or 4P configurations to suit the circuit and local installation rules.

For buyers comparing a 6kA MCB, the CQB2-63 circuit breaker provides B, C and D choices within its published MCB trip curve options.

For distributors, panel builders and electrical OEMs, the series combines a consistent 6kA breaking-capacity platform with a broad configuration range. Selection should still be based on conductor ampacity, load behavior, prospective short-circuit current, ambient conditions and the destination market. The CQB2-63 is specified to IEC 60898-1, and CCC is the certification confirmed for this model on the current product page.

Características clave

  • 6kA rated short-circuit breaking capacity: the published technical data states Icn = Ics = 6000A.
  • 6A to 63A rated-current range: available ratings are 6, 10, 16, 20, 25, 32, 40, 50 and 63A.
  • B, C and D tripping curves: options cover different instantaneous-trip requirements and load inrush profiles.
  • Multiple pole configurations: 1P, 1P+N, 2P, 3P, 3P+N and 4P versions support common single- and three-phase distribution arrangements.
  • Verified model data: rated insulation voltage is 500V, rated impulse withstand voltage is 4kV, and the degree of protection is IP20.
  • Defined service-life figures: the product data lists at least 10,000 mechanical operations and at least 6,000 electrical operations under the stated conditions.

Aplicaciones típicas

The CQB2-63 is intended for final circuits in residential, commercial and light-industrial distribution systems. Typical uses include lighting, socket-outlet, small HVAC, pump and other branch circuits when the selected rating and trip curve match the conductor, load and fault-current study. An MCB primarily protects the circuit conductors, so selection must account for cable size, installation method, ambient temperature, grouping and upstream coordination rather than the appliance name alone.

Guía de Solicitudes y Selección

Selection item How to evaluate it CQB2-63 options
Corriente nominal Confirm design current, conductor ampacity, installation method, ambient temperature and grouping. Do not increase the breaker rating to solve repeated tripping without diagnosing the cause. 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Tripping curve Compare normal operating current, starting or inrush current and the fault-current level needed for timely magnetic operation. B, C or D
Número de polos Match the supply system and determine which live conductors—and, where required, the neutral—must be disconnected together. 1P, 1P+N, 2P, 3P, 3P+N, 4P
Capacidad de corte Verify that the prospective short-circuit current at the installation point does not exceed the device rating. Use another protective solution if the study requires a higher value. 6kA, Icn = Ics
Standard and market documents Check the product standard, destination-market rules and the exact documents required by the customer or approval body. IEC 60898-1; CCC confirmed on this page

Compare breaking capacity, tripping curves, pole configurations and protection functions before selecting the right miniature circuit breaker for your application.

6kA vs 10kA MCB

Select breaking capacity according to the prospective short-circuit current at the installation point, not only the rated current of the circuit.

Fault LevelDistribution DesignProject Safety

Need Help Selecting an MCB Configuration?

Share your pole configuration, rated current, tripping curve and quantity. Our team will help confirm a suitable CQB2-63 option for your application.

Solicitar un presupuesto

Guía de pedidos

Professional MCB product pages commonly identify operating and storage conditions, mounting format, conductor capacity, tightening torque, dimensions and weight. These values vary by product family, rated current and pole configuration, so figures from another brand or series should not be applied to the CQB2-63. Confirm the following items on the approved CQB2-63 datasheet, installation instructions or project quotation before final selection:

  • Operating conditions: permitted ambient and storage temperature ranges, enclosure conditions and any temperature or grouping derating.
  • Mounting details: approved rail or panel mounting method, installation orientation, module width and the clearance needed for wiring and maintenance.
  • Terminal requirements: accepted conductor type and cross-section, stripping length and the specified terminal-tightening torque.
  • Dimensions and weight: exact dimensions and net weight for the selected 1P, 1P+N, 2P, 3P, 3P+N or 4P configuration.
  • Commercial details: sample availability, minimum order quantity, packaging format, documentation package and production lead time for the required market.

For a project-specific confirmation, send CHAC the rated current, trip curve, pole configuration, destination market, expected quantity and panel or conductor constraints.

How to choose between B, C and D curves

The curve identifies the instantaneous magnetic-trip range, not a general quality grade. The CQB2-63 tripping table gives 3–5 × In for B curve, 5–10 × In for C curve and 10–20 × In for D curve. B curve is commonly considered for low-inrush circuits, C curve for moderate inrush, and D curve for higher-inrush equipment. The final choice must still provide adequate fault protection; selecting a slower curve only to avoid nuisance trips can delay operation when fault current is limited.

How to choose the pole configuration

Select the pole arrangement from the actual supply and isolation requirements rather than from panel space alone. A 1P device switches one conductor, while multi-pole versions provide mechanically linked operation for the specified conductors. Neutral switching and isolation rules vary by system and market, so 1P+N, 3P+N and 4P options should be confirmed against the project drawings and local requirements.

When 6kA is not enough

A 6kA marking means the breaker is rated to interrupt a prospective short-circuit current of up to 6,000A under the applicable test conditions; it is not the normal load-current rating. If the calculated or measured prospective fault current at the installation point exceeds 6kA, use equipment with a suitable rating or a verified coordinated solution rather than assuming every MCB is interchangeable.

Designación del tipo

Curvas de disparo

Dimensions(unit:mm)

Especificaciones técnicas

Parámetro
Rated insulation voltage 500 V
Tensión soportada de impulso nominal (Uimp) 4000 V
Corriente nominal 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Frecuencia nominal 50 Hz / 60 Hz
Número de polos 1P, 1P+N, 2P, 3P, 3P+N, 4P
Poder de corte nominal (Icn = Ics) 6000 A
Vida mecánica ≥ 10,000 operations
Vida eléctrica ≥ 6,000 operations
Tripping characteristics B, C, D
Terminal center distance 45 mm
Grado de protección IP20
Estándares IEC 60898-1, GB/T 10963.1
Certificación CCC

Table 1 Tripping characteristics (Reference temperature 30°C)

Artículo Curva de disparo Prueba corriente en (A) Estado inicial Límite de tiempo para disparar o no disparar Resultado esperado Observaciones
a B, C, D 1,13 ln Frío t ≤ 1 h No desatascador La corriente sube suavemente al valor especificado en 5s
b B, C, D 1.45ln Siguiendo el ítem una prueba t<1h Tropezando
c B, C, D 2,55 ln Frío 1s<t<60s(ln≤32A)
1s<t<120s(ln>32A)
Tropezando
d B 3En Frío t ≤ 0,1 s No desatascador Enciende la fuente de alimentación cerrando el interruptor auxiliar
C 5In
D 10ln
e B 5In Frío t<0,1s Tropezando Enciende la fuente de alimentación cerrando el interruptor auxiliar
C 10ln
D 20ln

Nota: El término “en frío” significa que la prueba se realiza a una temperatura de calibración de referencia sin carga antes de la prueba.

Requisitos del conductor y sección transversal

Sección transversal de cobre (mm²) Corriente nominal In(A)
1 En≤6
1.5 6 In≤13
2.5 13 In≤20
4 20 In≤25
6 25 In≤32
10 32 In≤50
16 50 In≤63

¿Por qué elegir CHAC?

Con más de 30 años de experiencia en fabricación, más de 1100 empleados, más de 100 millones de postes
Con una capacidad anual y un proceso de producción automatizado 90%, CHAC ofrece una capacidad de producción estable y un estricto
control de calidad para clientes OEM/ODM globales. Nuestro sistema de fabricación interno respalda a largo plazo
Cooperación para marcas eléctricas, importadores y distribuidores.


30+

AÑOS DE EXPERIENCIA

Especializado en fabricación eléctrica de bajo voltaje


1100+

EMPLEADOS

Equipo profesional garantiza calidad y entrega estables


100M+

CAPACIDAD ANUAL DE LOS POLOS

Capacidad de producción a gran escala para satisfacer la demanda mundial


90%

PRODUCCIÓN AUTOMATIZADA

Automatización avanzada para alta eficiencia y consistencia

Línea de ensamblaje automatizada

Línea de ensamblaje automatizada

Laboratorio de pruebas

Laboratorio de pruebas

Inyección y Estampado

Inyección y Estampado

Inspección de calidad

Inspección de calidad

Certificación IEC
Certificación CE
Certificación CB
Certificación RoHS
Certificación ISO 14001

Un estricto sistema de control de calidad garantiza que cada producto cumpla con los estándares mundiales.

¿Qué podemos personalizar?

CQB2-63 OEM/ODM options are reviewed per project rather than assumed to be available for every configuration. The published 6–63A ratings, B/C/D curves and listed pole arrangements are the starting platform. Marking, packaging, labels, manuals, appearance requests, engineering work and certification support depend on technical feasibility, order quantity, tooling requirements and the destination market. Changes to internal construction, breaking capacity, terminals, dimensions or certified ratings require separate engineering and compliance confirmation.

Logotipo y marca

Logo and marking requests are reviewed against the available print area, required regulatory markings and approved artwork.

Logotipo y marca

Empaquetado
Personalización

Color boxes, cartons, labels and manuals can be reviewed by language, destination market and order quantity.

Personalización de empaques

Eléctrico
Personalización

Available rated-current, pole and B/C/D curve combinations are reviewed within the validated CQB2-63 platform.

Personalización Eléctrica

Producto
Apariencia

Housing or handle color requests require technical, material, tooling and compliance review before sampling.

Apariencia del producto

Certificación
Apoyo

Destination-market documents and certification requirements are reviewed for the exact model and configuration before sample approval.

Soporte de Certificación

Ingeniería
Desarrollo

Drawing, prototype and validation support is scoped per project; internal construction or rating changes are not assumed.

Desarrollo de Ingeniería

Descargar

PDF

Interruptor automático en miniatura serie CQB2

Descripción general completa de componentes eléctricos de bajo voltaje y referencia para la selección de productos.

Descargar PDF

Arriba

¿Necesita documentos técnicos?

Contáctenos para obtener hojas de datos, certificados, planos, orientación de selección o soporte para proyectos OEM/ODM.

Contáctanos

CQB2-63 Miniature Circuit Breaker FAQ

How to choose the correct MCB?

Start with the conductor ampacity and circuit design current, then check the supply voltage, pole configuration, load inrush, ambient conditions and prospective short-circuit current. For the CQB2-63, select within 6–63A, match the B/C/D curve to the load and fault conditions, and verify that the installation point does not exceed the 6kA breaking-capacity rating.

What are the different types of poles in an MCB?

MCBs may switch one or several conductors together. The CQB2-63 is offered in 1P, 1P+N, 2P, 3P, 3P+N and 4P configurations; the correct option depends on the single- or three-phase system and whether the neutral must be switched or isolated under the applicable rules.

What does kA mean on circuit breakers?

kA indicates short-circuit breaking capacity, not continuous load current. The CQB2-63 has a 6kA rating, meaning it is designed to interrupt up to 6,000A of prospective short-circuit current under the stated IEC 60898-1 test conditions; the installation must be checked to confirm that this rating is sufficient.

What is the difference between a 1-pole MCB and a 2-pole MCB?

A 1-pole MCB operates one conductor, while a 2-pole MCB provides linked operation across two conductors. The choice depends on the supply arrangement and disconnection rules; two unrelated single-pole breakers should not be assumed to provide the same common operation as a purpose-designed 2P device.

What is the C curve and D curve in an MCB?

For the CQB2-63, the published instantaneous magnetic-trip ranges are 5–10 × In for C curve and 10–20 × In for D curve. D curve tolerates more starting current, but it should only be used when the load profile and available fault current allow the protective device to operate within the required disconnection time.

When should a B-curve MCB be used?

B curve is generally considered for circuits with relatively low starting or inrush current. The CQB2-63 data gives a B-curve magnetic-trip range of 3–5 × In; engineers should still confirm conductor protection, normal transients and fault-loop conditions rather than choosing the curve from the load label alone.

Build the Right CQB2-63 Configuration for Your Market

Send us your required current rating, B/C/D curve, pole configuration, destination market and estimated quantity. CHAC will review the specification and provide the relevant technical documents and commercial proposal.

Solicitar un presupuesto