Interruptor automático en caja moldeada de la serie CQM7DC
El CQM7DC MCCB provides overload and short-circuit protection for DC systems within its published 63–1600A range. Specification should follow the system voltage, load, conductor coordination, prospective fault current and applicable rules—not the ampere value alone.
Descripción del producto
CQM7DC is a dc MCCB for 1500V DC distribution and protection applications. Its published range covers 63–1600A with 2P / 3P / 4P options. Selection depends on the complete power-system design, including fault level, coordination, conductor ampacity, enclosure conditions and local rules.
The saved model record lists UL 489 requirements listed on the page as the applicable standard reference. No certification claim is added beyond the model record.
Características clave
Aplicaciones típicas
Typical applications include solar PV, EV charging and energy-storage distribution where the complete DC fault study supports the rating. These are evaluation contexts rather than universal approvals. Confirm the exact frame, voltage, breaking duty, trip unit, accessories and installation method before specification.
Guía de Solicitudes y Selección
Use the verified CQM7DC values below to create a shortlist, then validate the complete circuit. An MCCB rating does not replace conductor calculations, fault-current analysis, coordination review or local installation requirements.
| Punto de selección | CQM7DC reference | Lo que el proyecto debe confirmar |
|---|---|---|
| Corriente nominal | 63–1600A | Diseño actual, capacidad de carga del conductor, método de instalación, temperatura y agrupamiento |
| Voltaje | 1500 V CC | Sistema de suministro y capacidad nominal de los equipos |
| Polacos | 2P / 3P / 4P | Tratamiento de conductores bajo tensión y del conductor neutro |
| Viaje / protección | 5In or 10In instantaneous setting | Perfil de carga, respuesta a fallos y coordinación |
| Capacidad de corte | Icu/Ics values vary by voltage and frame; verify the ordered table | Corriente de cortocircuito prevista en el punto de instalación |
AC MCCB vs DC MCCB
DC interruption is not interchangeable with AC interruption. Use the CQM7DC voltage, pole, arc-distance and fault-duty data for the intended PV, EV or storage circuit.
DC Interruption
Review DC MCCB Range →
MCCB frente a MCB
Un MCCB suele evaluarse en función de su capacidad para soportar corrientes más elevadas, su rendimiento en caso de fallo o la flexibilidad de sus accesorios; un MCB puede ser más adecuado para circuitos finales de tamaño reducido.
Corriente y capacidad de cortocircuito
Comparar MCCB y MCB →
UCI frente a UCI
The saved data for CQM7DC lists Icu/Ics values vary by voltage and frame; verify the ordered table. Match the declared duty to the prospective short-circuit current and continuity objective.
Estudio de cortocircuito
Revisar el soporte técnico →
Disposición del polo y el neutro
Published pole options are 2P / 3P / 4P. Confirm which conductors must be switched, protected and isolated together.
Disposición del sistema
Ver gama de MCCB →
Guía de pedidos
- State the exact model: CQM7DC.
- Provide frame and rated current within the published range: 63–1600A.
- Confirm poles: 2P / 3P / 4P.
- Specify the trip unit or protection function: 5In or 10In instantaneous setting.
- Proporcione el voltaje del sistema, la frecuencia, la aplicación, el nivel de falla esperado, el mercado de destino y la cantidad.
- Enumere los accesorios requeridos, los terminales, los documentos y cualquier requisito aprobado de marcado o embalaje del OEM/ODM.
Comprobaciones de Instalación y Coordinación
- Utilice el dibujo del modelo y las instrucciones exactos; no infiera las posiciones de los terminales, la dirección de alimentación ni la compatibilidad de los accesorios a partir de otro MCCB.
- Verifique el material del conductor y la sección transversal en función del cálculo del circuito, los datos de los terminales, la temperatura y el agrupamiento.
- Confirmar la capacidad de interrupción en caso de falla en UCI/UCS o en corriente continua, la coordinación entre equipos aguas arriba y aguas abajo, las condiciones de la caja de distribución, la altitud y las separaciones mínimas.
- La instalación, el aislamiento, las pruebas y el mantenimiento deben ser realizados por personal cualificado, de conformidad con las normas aplicables.
Designación del tipo

Lista de accesorios

Note: Code 50:For models 125 and 160, a custom left-side undervoltage release is required. For model 250, a custom left-side shunt release is required.Optional voltage ranges for shunt/undervoltage releases:DC24V, DC110V, DC220V, AC230V, AC400V.Standard production voltage: AC230V.
Especificaciones técnicas
| Parámetro | CQM7DC-320 | CQM7DC-630 | CQM7DC-1600 |
| Corriente Nominal (A) | 63, 80, 100, 125, 140, 160, 180, 200, 225, 250, 315, 320 | 225, 250, 320, 350, 400, 500, 630 | 800, 1000, 1250, 1500, 1600 |
| Número de polos | 2P | 2P | 3P,4P |
| Rated Operational Voltage Ue DC (V) | 1500 | 1500 | 1500 |
| Rated Insulation Voltage Ui (V) | 1800 | 1800 | 1800 |
| Rated Impulse Withstand Voltage Uimp (kV) | 12 | 12 | 12 |
| Power Frequency Withstand Voltage (1 min) (kV) | 3.5 | 3.5 | 3.5 |
| Rated Ultimate Short-Circuit Breaking Capacity Icu | DC1200V DC1500V | DC750V DC1000V | DC750V DC1000V DC1200V DC1500V |
| Rated Service Short-Circuit Breaking Capacity Ics (kA) | 35kA 20kA | 85kA 50kA | 50kA 30kA 15kA 10kA |
| Vida mecánica (operaciones) | 4000 | 4000 | 4000 |
| Vida eléctrica (operaciones) | 10000 | 10000 | 500 |
| Arc Chute Distance (mm) | 50 / 0 | 50 / 0 | 50 / 0 |
| Dimensions W×L×H (mm) | 90×215×136 | 110×275×152 | 3P: 210×340×244 4P: 280×340×244 |
| Instantaneous Trip Setting | 5In or 10In | 5In or 10In | 5In or 10In |
| Reference Ambient Temperature (℃) | 50 | 50 | 50 |
¿Por qué elegir CHAC?
Con más de 30 años de experiencia en fabricación, más de 1100 empleados, más de 100 millones de postes
Con una capacidad anual y un proceso de producción automatizado 90%, CHAC ofrece una capacidad de producción estable y un estricto
control de calidad para clientes OEM/ODM globales. Nuestro sistema de fabricación interno respalda a largo plazo
Cooperación para marcas eléctricas, importadores y distribuidores.

30+
AÑOS DE EXPERIENCIA
Especializado en fabricación eléctrica de bajo voltaje

1100+
EMPLEADOS
Equipo profesional garantiza calidad y entrega estables

100M+
CAPACIDAD ANUAL DE LOS POLOS
Capacidad de producción a gran escala para satisfacer la demanda mundial

90%
PRODUCCIÓN AUTOMATIZADA
Automatización avanzada para alta eficiencia y consistencia

Línea de ensamblaje automatizada

Laboratorio de pruebas

Inyección y Estampado

Inspección de calidad





Un estricto sistema de control de calidad garantiza que cada producto cumpla con los estándares mundiales.
¿Qué podemos personalizar?
For CQM7DC projects, CHAC can review private-label marking, packaging, approved appearance options, published 63–1600A electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, minimum order quantity and project feasibility.
Recinto
Diseño
Tamaños, estructuras y detalles de instalación de recintos personalizados.

Interno
Configuración
Opciones flexibles de diseño interno y disposición de componentes.

Marca e
Logo
Logotipos de marca propia, placas de identificación e identificación de marca.

Empaquetado
Diseño
Soluciones de embalaje, cajas personalizadas, etiquetas y manuales.

Eléctrico
Configuración
Instalación eléctrica adaptada a los requisitos de la aplicación.

Certificación
Apoyo
Soporte para estándares del mercado objetivo y requisitos de cumplimiento.

Descargar
Otros Productos
Descripción general completa de componentes eléctricos de bajo voltaje y referencia para la selección de productos.
¿Necesita documentos técnicos?
Contáctenos para obtener hojas de datos, certificados, planos, orientación de selección o soporte para proyectos OEM/ODM.
CQM7DC Product FAQ
What is the CQM7DC MCCB used for?
The CQM7DC is specified for overload and short-circuit protection for DC systems in 1500V DC systems within the published 63–1600A range. Suitability depends on the fault study, conductor coordination, enclosure and local rules.
What is the CQM7DC 1500V DC rating?
The page lists 1500V DC as the rated operational voltage. DC interruption is not interchangeable with AC interruption, so the pole arrangement, arc path, fault current and installation instructions must be checked for the actual PV, EV or storage circuit.
How do I choose the CQM7DC rated current and poles?
Start with the design current and conductor calculation, then choose a published current within 63–1600A and poles from 2P / 3P / 4P. Neutral treatment, fault level, ambient conditions and coordination also need review.
What breaking capacity should I check on the CQM7DC?
Use the declared Icu/Ics values vary by voltage and frame; verify the ordered table for the exact frame, voltage and configuration. The prospective short-circuit current at the installation point must be within the applicable duty; a larger ampere value alone is not a selection rule.
Can the CQM7DC replace an MCB or an earth-leakage device?
An MCCB is not automatically a like-for-like replacement. The CQM7DC provides overload and short-circuit protection for DC systems; residual-current protection, DC interruption, adjustable settings and other functions must be confirmed separately from the project requirement.
How should the CQM7DC be installed and tested?
Utilice únicamente el plano del modelo exacto, la identificación de terminales y las instrucciones de los accesorios. Una persona cualificada debe verificar la aislación, el tamaño de los conductores, el par de apriete, las separaciones mínimas, las configuraciones, la capacidad de soportar cortocircuitos y realizar pruebas funcionales antes de energizar el circuito.
Confirm the Right CQM7DC Configuration
Envíe la caja, la corriente nominal, el número de polos, la función de protección, la tensión del sistema, el nivel de falla esperado, el mercado de destino y la cantidad. CHAC revisará la solicitud en función de la gama de modelos publicada.