CQL14 Series Electromagnetic Protection Residual Current Device
Itu CQL14 Direkomendasikan untuk perlindungan arus sisa tanpa perlindungan arus berlebih. Pilihannya berdasarkan tegangan, arus, kutub, dan data perlindungan yang tercatat, kemudian konfirmasi koordinasi kabel, kondisi kerusakan, persyaratan penutup, dan aturan pemasangan lokal.
Gambaran Produk
CQL14 is a electromagnetic residual current device for AC 230/400V applications. It is intended for residential, commercial and industrial circuits where a separate overcurrent device is coordinated; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.
residual-current protection without overcurrent protection is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.
Fitur Utama
Aplikasi Biasa
residential, commercial and industrial circuits where a separate overcurrent device is coordinated. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.
Permohonan dan Panduan Pemilihan
Use the verified CQL14 records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.
| Titik pemilihan | CQL14 reference | Hal yang harus dipastikan oleh proyek tersebut |
|---|---|---|
| Rated current | Use the exact model table | Design current, conductor capacity, ambient and grouping |
| Voltage and frequency | AC 230/400V | Supply system and equipment rating |
| Tiang | 2P / 4P | Conductors to be switched, protected or isolated |
| Protection / control | Proteksi arus sisa tanpa proteksi arus berlebih | Required function and adjacent-device coordination |
| Fault / residual data | Pilihan 30mA, 100mA atau 300mA | Prospective short-circuit or leakage conditions |
RCCB vs RCBO
An RCCB addresses residual-current protection; an RCBO combines residual-current and overcurrent functions. Choose the architecture required by the protection study.
Protection Function
Compare RCBO Options →
Model-Specific Ratings
Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.
Verified Data
View Technical Support →
Installation and Coordination
Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.
Engineering Check
Discuss a Configuration →
Ordering Information
State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.
Project Inputs
Send Project Details →
Panduan Pemesanan
- State the exact model: CQL14.
- Provide rated current and voltage from the published technical table.
- Confirm poles and the required protection, isolation or control function.
- Provide application, expected fault/leakage conditions, destination market and quantity.
- List accessory, terminal, documentation and approved marking or packaging requirements.
Pengujian Instalasi dan Koordinasi
- Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
- Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
- Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
- Installation, testing and maintenance must be completed by qualified personnel under applicable rules.
Penamaan tipe

Dimensi (mm)

Spesifikasi Teknis
| Parameter | Spesifikasi |
| Rated Voltage | 230V AC (1P+N); 400V AC (3P+N) |
| Rated Current (A) | 25A, 40A, 63A, 80A, 100A |
| Rated Residual Operating Current | 0.03A, 0.1A, 0.3A |
| Rated Residual Non-Operating Current | 0.5I△n |
| Type of Residual Current (with DC component) | AC type, A type (In=25, 40, 63A) |
| Number of Poles | 1P+N, 3P+N |
| Rated Conditional Short-Circuit Current | 6000A |
| Rated Conditional Residual Short-Circuit Current | 6000A |
| Rated Making and Breaking Capacity | 500A (In=25, 40A); 10In (63, 80, 100A) |
| Rated Residual Making and Breaking Capacity | 500A (In=25, 40A); 10In (63, 80, 100A) |
| Tightening Torque | (2.5 ~ 3.0) N·m |
| Protection Class | IP20 |
| Pollution Degree | 2 |
| Installation Category | Ⅱ |
| Standar | GB 16916.1, IEC61008-1 |
Operating time (for residual current devices)
| In (A) | IΔn (A) | Breaking time when the residual current equals the following values(s) | ||||
| IΔn | 2IΔn | 5IΔn | 5A、10A、20A、50A、100A、200A | IΔt | ||
| 25~100A | 0.03、0.1、0.3 | 0.1 | 0.05 | 0.04 | 0.04 | 0.04 |
Mechanical and electrical endurance
| In (A) | Number of operating cycles | Operating frequency (cycles per hour) | |
| Number of on-load operating cycles | Number of no-load operating cycles | ||
| 25A | 2000 | 4000 | 240 |
| 40A, 63A, 80A, 100A | 2000 | 4000 | 120 |
Mengapa Memilih CHAC
Dengan pengalaman manufaktur lebih dari 30 tahun, 1100+ karyawan, dan 100M+ tiang
kapasitas tahunan dan produksi otomatis 90% unit, CHAC memberikan kapasitas produksi yang stabil dan ketat
Pengendalian kualitas untuk pelanggan OEM/ODM global. Sistem manufaktur internal kami mendukung jangka panjang
Kerjasama untuk merek-merek listrik, importir dan distributor.
30+
BERKALI-KALI BERKEMBANG
Mengkhususkan diri dalam manufaktur listrik tegangan rendah
1100+
KARYAWAN
Tim profesional memastikan kualitas dan pengiriman yang stabil
100 juta+
Kapasitas Bulanan POKER
Kapasitas produksi berskala besar untuk memenuhi permintaan global
90%
PENGELOLAAN PRODUKSI AUTOMATIS
Otomasi canggih untuk efisiensi dan konsistensi yang tinggi

Barisan Perakitan Otomatis

Laboratorium Pengujian

Injeksi & Stamping

Pemeriksaan Kualitas





Sistem kontrol kualitas yang ketat memastikan setiap produk memenuhi standar global.
Apa yang Dapat Kami Sesuaikan?
For CQL14 projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.
Logo & Branding
Penerbitan logo khusus, pencetakan laser dan solusi stiker nama.

Kemasan
Kustomisasi
Kotak warna, karton, label, dan manual yang disesuaikan.

Elektrik
Kustomisasi
Current, voltage, breaking capacity, trip curve and other
special functions.

Produk
Penampilan
Kustomisasi warna perumahan, warna pegangan, dan tampilan.

Sertifikasi
Dukungan
Products comply with international standards and market
requirements.

Teknologi
Pembangunan
Pengerjaan evaluasi, pengujian prototipe, dan produksi massal.

Unduh
Produk Lainnya
Complete product overview for low-voltage electrical components and product selection reference.
Butuh Dokumen Teknis?
Hubungi kami untuk mendapatkan data spesifikasi, sertifikat, gambar, panduan pemilihan, atau dukungan proyek OEM/ODM.
CQL14 Product FAQ
What is the CQL14 used for?
The CQL14 is specified for residual-current protection without overcurrent protection in AC 230/400V applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.
How does the CQL14 work?
Its operating principle follows the documented function: residual-current protection without overcurrent protection. Use the exact model documentation for thresholds, timing, trip behaviour, terminals and test procedures.
How do I choose the CQL14 rating and poles?
Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 2P / 4P; confirm neutral, polarity, conductors and isolation requirements.
What safety limitation applies to the CQL14?
Do not treat the CQL14 as a universal substitute for another device. Confirm 30mA, 100mA or 300mA options, the system voltage, fault or leakage conditions and any separate upstream protection before selection.
Can the CQL14 be used in another circuit type?
Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.
How should the CQL14 be installed and tested?
Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.
Confirm the Right CQL14 Configuration
Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.





