CQDS-32 Saklar isolasi DC fotovoltaik
The CHAC CQDS-32 photovoltaic DC isolation switch provides isolation and infrequent switching between PV modules and inverters. Its non-polar design supports selected DC-PV1/DC-PV2 configurations up to 1200V DC and 32A; follow the wiring arrangement specified for the chosen configuration.
Gambaran Produk
CHAC CQDS-32 photovoltaic DC isolation switch provides a disconnection point between PV modules and the inverter. Its non-polar design, lockable handle and DC-PV1/DC-PV2 options support selection for the actual string arrangement rather than voltage alone.
Bagi para importir, distributor, dan produsen peralatan, CHAC dapat meninjau konfigurasi yang diminta sesuai dengan persyaratan sirkuit serta dokumen pasar tujuan. Pastikan kesepakatan mengenai model yang tepat, gambar teknis, dan persyaratan penandaan sebelum persetujuan sampel atau pemesanan ulang.
Poin-Poin Pilihan Utama
Aplikasi Biasa
Use the CQDS-32 in a protected PV assembly where the design requires DC isolation and infrequent switching. The IP20 device needs a suitable enclosure; it is not a weatherproof rooftop disconnect by itself.
Permohonan dan Panduan Pemilihan
| Item seleksi | CQDS-32 configuration | Hal yang harus diverifikasi |
|---|---|---|
| Operating duty | DC-PV1 / DC-PV2 | Match the switching duty to the PV string arrangement and possible reverse current. |
| Voltage and current | Up to 1200V DC / 32A, configuration dependent | Confirm the paired voltage/current rating and wiring diagram; do not combine independent maximum values. |
| Connections | Four-pole configurations with designated connection diagrams | Use the specified terminal bridges and conductor arrangement, not a layout inferred from the number of poles. |
| Pemasangan | IP20; vertical or horizontal installation | Confirm enclosure protection, access to the handle and cable bending space. |
Use these checks to compare the protection function, configuration and related CHAC products before specifying CQDS-32. Related products are selection alternatives or system components, not automatic replacements.
Choose the switching duty for the PV array
Parallel strings can introduce reverse-current conditions that a simple voltage check misses.
Use the wiring diagram for the ordered configuration
A non-polar design does not make every series connection acceptable.
Compare CQHS for the required function
The CHAC CQHS PV DC combiner box combines photovoltaic string inputs with a DC isolator for DC-side disconnection. Choose from six input/output configurations to match your PV array layout, and confirm the voltage and current ratings for the selected model.
Compare CQBD-63 for the required function
Pemutus sirkuit DC CHAC CQBD-63 menawarkan perlindungan terhadap beban lebih dan arus pendek dengan desain non-polar dan indikasi posisi kontak. Versi satu hingga empat kutub mencakup tegangan DC dari 300V hingga 1200V; sesuaikan susunan kutub dan karakteristik tripping dengan sirkuit.
Need Help Specifying CQDS-32?
Send the circuit requirements, selected configuration, destination market and quantity for a model-specific review.
Choose the switching duty for the PV array
Parallel strings can introduce reverse-current conditions that a simple voltage check misses. Provide the string arrangement, maximum open-circuit voltage at the lowest design temperature and design current. CHAC can then confirm the applicable CQDS-32 configuration and utilization category.
Use the wiring diagram for the ordered configuration
A non-polar design does not make every series connection acceptable. Match the terminal arrangement to the approved drawing and check that all required live conductors are isolated. The switch does not replace the array overcurrent-protection design.
How to Specify a CQDS-32 Order
Use the configuration details below in the purchase specification. Keep the approved drawing revision and product identification with the order so repeat deliveries can be checked consistently.
| Rincian pesanan | Information to include |
|---|---|
| Operating duty | DC-PV1 / DC-PV2 — Match the switching duty to the PV string arrangement and possible reverse current. |
| Voltage and current | Up to 1200V DC / 32A, configuration dependent — Confirm the paired voltage/current rating and wiring diagram; do not combine independent maximum values. |
| Connections | Four-pole configurations with designated connection diagrams — Use the specified terminal bridges and conductor arrangement, not a layout inferred from the number of poles. |
| Pemasangan | IP20; vertical or horizontal installation — Confirm enclosure protection, access to the handle and cable bending space. |
| Project and documents | Supply the application, installation conditions and destination-market document requirements. |
| Quantity and identification | State the quantity, sample requirement, packaging language and any proposed branding; confirm feasibility before approval. |
Check Installation Fit Before Approval
Parameter table
| Electrical Characteristics | |
| model | DS1-32 |
| function | Isolation and control |
| standard | IEC60947-3,AS60947.3 |
| Usage category | DC-PV1 / DC-PV2 |
| series | 4P |
| rated frequency | DC |
| Rated working voltage (Ue) | 300V/600V/800V/1000V/1200V |
| Rated insulation voltage (Ui) | 1200V |
| Rated short-time withstand current (Icw) | 1KA/1S(4,4S,4B),1.7KA/1S(2H) |
| Rated impulse withstand voltage (Uimp) | 8.0KV |
| overvoltage category | Ⅱ |
| polarity | Mechanical polarity is non-polar,and the “+” and “-” polarities can be interchanged. |
| Service life/number of operations | |
| mechanical life | 9700 |
| electrical life | 300 |
| Installation environment | |
| Protection level | IP20 |
| Storage temperature | -40℃~+85℃ |
| Installation Type | Vertical or horizontal |
| pollution level | 3 |
Wiring swap – corresponding diagrams
| 4-pole | 4T Four pole with input terminalOutput top |
4-pole Bottom input and output |
4-pole top input,bottom output | |
| Spesifikasi | 4 | 4B | 4S | |
| Contact point connection line graph | ![]() |
![]() |
![]() |
![]() |
| switch example | ![]() |
![]() |
![]() |
![]() |
Product model and meaning

Product dimensions

Mengapa Memilih CHAC
CHAC Electric supplies electrical protection and control products for importers, distributors and equipment brands. For CQDS-32, agree the configuration, technical documents, approved sample and identification requirements before production. The company facilities shown below provide company context, not a claim that every model uses the same production or test process.
01
KONFIRMASI SPESIFIKASI
Agree the CQDS-32 configuration, circuit duty and installation requirements.
02
TINJAU DOKUMEN-DOKUMEN
Konfirmasikan gambar yang spesifik untuk model dan persyaratan pasar tujuan.
03
SETUJUI SAMPEL
Catat konfigurasi yang diterima dan persyaratan penandaan.
04
TENTUKAN CEK PESANAN
Setujui persyaratan pengemasan, identifikasi, dan pengiriman dalam penawaran.

Barisan Perakitan Otomatis

Laboratorium Pengujian

Injeksi & Stamping

Pemeriksaan Kualitas
Apa yang Dapat Kami Sesuaikan?
Discuss CQDS-32 product identification, packaging and documentation with CHAC. Each proposed change is subject to technical feasibility, marking rules and approval of the exact order; no altered rating or certification is implied.
Logo & Branding
Kirimkan karya seni logo dan persyaratan penandaan untuk ditinjau sesuai dengan area cetak yang tersedia serta penandaan produk wajib.

Kemasan & Manual
Tentukan label karton, bahasa pada kemasan, identifikasi produk, serta persyaratan instruksi untuk pasar tujuan.

Pemilihan Konfigurasi
Specify CQDS-32 with the required operating duty, operating conditions and protection duty. Confirm the complete order combination.

Assembly Requirements
Provide the mounting and connection requirements for review. Changes to the housing, terminals or operating arrangement require engineering approval.

Dokumentasi Pasar
Request documents covering the exact CQDS-32 model and destination market. A standard reference alone is not evidence of certification.

Persetujuan Sampel
Setujui spesifikasi sampel, revisi gambar, dan kriteria penerimaan sebelum memastikan pesanan produksi.

Dokumen Teknis dan Dukungan
CQDS-32 Technical Documents
Request the CQDS-32 datasheet, configuration drawing, installation instructions and available model-specific market documents.Minta Lembar Data
Butuh Dokumen Teknis?
Send the application, electrical requirements, assembly layout and destination market for configuration and document review.Hubungi Kami
CQDS-32 Product FAQ
Can a DC isolator switch replace a circuit breaker?
No. The CQDS-32 provides switching and isolation, not an automatic overload or short-circuit trip function. Specify the required fuse or circuit breaker separately and coordinate it with the PV circuit.
What is the difference between DC-PV1 and DC-PV2?
They identify different PV switching duties, including different reverse-current conditions. Select the category using the array arrangement and manufacturer ratings. The CQDS-32 lists both categories, but the applicable voltage, current and wiring combination must be confirmed.
Can CQDS-32 be installed outdoors without a box?
The device is IP20, so it should not be exposed as a standalone outdoor switch. Select an enclosure, glands and installation position suitable for the site and preserve the required operating access.
Can I choose CQDS-32 by current rating alone?
No. Check operating voltage, poles, utilization category, switching duty, fault coordination and the installation layout together. Confirm the selected combination in the model-specific documentation before approving a substitute.
Can an isolator be switched under load?
Only within its documented switching duty and voltage/current combination. Confirm the applicable utilization category and instructions for CQDS-32; do not assume that every device called an isolator has the same load-break capability.
What information is needed for a CQDS-32 quotation?
Provide the supply voltage, required current, load duty, pole arrangement, installation drawing and fault-coordination requirements. Add control or auxiliary-contact needs where applicable, plus quantity and destination market.
Specify the Right CQDS-32 Configuration
Send CHAC your required configuration, application, destination market and estimated quantity. We will review the requested specification and provide the relevant technical documents and commercial proposal.