FB2H-63 Miniature Circuit Breaker

The FB2H-63 miniature circuit breaker provides overload and short-circuit protection within the published 10A–63A range. Its verified product data lists 10kA Icu; 7.5kA Ics, 1P / 2P and C. Final selection must match the conductor, load, prospective fault current, installation system and applicable local rules.

Poles:
1P / 2P
Rated Current:
10A–63A
Electrical Rating:
240V AC
Frequency:
50/60Hz
Breaking Data:
10kA Icu; 7.5kA Ics
Trip / Residual Type:
C
Standard:
IEC 60898-1
Mounting:
Plug-in mounting

Product Overview

FB2H-63 is a 10kA Icu; 7.5kA Ics miniature circuit breaker covering 10A–63A. It is available with 1P / 2P and C trip options as stated in the product data. For the FB2 plug-in family, confirm the receiving panel and base arrangement; a matching current rating alone does not establish compatibility.

The model data references IEC 60898-1. Standards, certification scope and technical documents must be confirmed for the ordered configuration and destination market.

Key Features

  • Published current range: 10A–63A.
  • Pole configuration: 1P / 2P.
  • Trip / protection option: C.
  • Short-circuit data: 10kA Icu; 7.5kA Ics.
  • Electrical reference: 240V AC, 50/60Hz.
  • Service-life data: 10,000 mechanical and 4,000 electrical operations.
  • Additional verified data: 500V Ui; 4kV Uimp; IP20; 1–25mm² conductor range; altitude ≤2,000m.

Typical Applications

It is intended for AC distribution circuits where the selected current rating, curve, pole arrangement and breaking capacity match the conductor and system study. Typical project contexts include residential, commercial and light-industrial final distribution; suitability depends on the actual circuit rather than the application label alone.

Applications and Selection Guide

Use the product-specific values below as a shortlist, then validate the complete circuit design. Product ratings do not replace a fault-current study, conductor calculation, coordination review or applicable installation rules.

Selection point FB2H-63 option What the project must confirm
Rated current 10A–63A Coordinate with design current, conductor ampacity, ambient temperature and grouping
Trip curve C Choose for load inrush and required fault-clearing performance, not by current alone
Breaking capacity 10kA Icu; 7.5kA Ics Confirm against the prospective short-circuit current at the installation point
Pole arrangement 1P / 2P Match supply system and local switching or isolation rules
Installation interface Plug-in mounting Check enclosure, rail/base, terminal and conductor compatibility

Breaking Capacity

10kA Icu; 7.5kA Ics is the published product value. Confirm the prospective short-circuit current at the installation point.

Fault LevelProject Selection

Trip and Load Behaviour

C is the available trip/protection option. Match it to load inrush and required disconnection performance.

Load InrushProject Selection

Pole Configuration

Available arrangement: 1P / 2P. Confirm which conductors must be switched and protected under local rules.

Circuit LayoutProject Selection

MCB or RCBO

An MCB does not replace residual-current protection where an RCD or RCBO is required.

Protection ScopeProject Selection

Ordering Guide

  1. Specify the exact model: FB2H-63.
  2. State the required current rating within 10A–63A.
  3. Confirm pole arrangement: 1P / 2P.
  4. Confirm trip or protection option: C.
  5. Provide system voltage, expected fault level, destination market, quantity and any document requirements.

Installation and Coordination Checks

  • Verify conductor material and cross-section against the circuit calculation and the published terminal range.
  • Confirm the prospective short-circuit current does not exceed the applicable breaking rating.
  • Check upstream/downstream coordination, enclosure temperature, grouping, altitude and required clearances.
  • Installation, isolation, testing and maintenance must be carried out by qualified personnel under applicable rules.

Type designation

Tripping curves

Dimensions(mm)

Technical Specifications

Parameter  
Bracket rating current 63A
Number of poles 1P, 2P
Feature Overload and short circuit protection
Rated frequency f(HZ) 50/60Hz
Rated operating voltage Ue(V AC) 240V~
Rated current In(A) 10,16,20,25,32,40,50,63A
Rated insulation voltage Ui(V) 500V
Rated impulse withstand voltage Uimp(kV) 4kV
Rated operating short-circuit breaking capacity (kA) 7.5 kA
Rated limit short-circuit breaking capacity (kA) 10kA
Current limiting class 3
Instantaneous trip characteristics Electromagnetic type
Trip type C
Electrical service life 4000 times
Service life of machinery 10000 times
Class of protection IP20
Wiring capability (mm2) 1 to 25mm2
Ambient temperature (daily average temperature ℃) 35 ℃ or less
Storage temperature -25℃ to +55℃
Types of climate protection Damp-heat type
Altitude (m) ≤2000m
Relative humidity of air 50% ~ 90%
Pollution level 2
Installation environment /
Installation category Ⅱ or Ⅲ
Installation mode plug-in
Meet the standard IEC 60898-1

 

Why Choose CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.


30+

YEARS EXPERIENCE

Specialized in low-voltage electrical manufacturing


1100+

EMPLOYEES

Professional team ensures stable quality and delivery


100M+

POLES ANNUAL CAPACITY

Large-scale production capacity to meet global demand


90%

AUTOMATED PRODUCTION

Advanced automation for high efficiency and consistency

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

IEC Certification
CE Certification
CB Certification
RoHS Certification
ISO 14001 Certification

Strict quality control system ensures every product meets global standards.

What Can We Customize?

For FB2H-63 projects, CHAC can review private-label marking, packaging, appearance, available electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, MOQ and project feasibility.

Logo & Branding

Private-label marking and nameplate options are subject to artwork review and sample approval.

Logo & Branding

Packaging
Customization

Cartons, labels and manuals can be prepared for the approved order specification and destination market.

Packaging Customization

Electrical
Customization

Select from the published 10A–63A, 1P / 2P and C options; non-standard requests require technical evaluation.

Electrical Customization

Product
Appearance

Appearance options can be reviewed subject to tooling, MOQ, marking requirements and technical feasibility.

Product Appearance

Certification
Support

Datasheets, drawings and verified certificate information are supplied for the applicable approved configuration.

Certification Support

Engineering
Development

Project support may include drawing review, sample evaluation, testing and production planning, subject to technical approval.

Engineering Development

Download

PDF

FB Series Miniature Circuit Breaker

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Contact Us

FB2H-63 Product FAQ

What does 10kA mean on the FB2H-63 breaker?

FB2H-63 publishes 10kA Icu and 7.5kA Ics short-circuit values. These describe fault-interruption duty, not its 10A–63A continuous rated-current range.

When should a 10kA plug-in MCB be used?

Only after confirming the prospective short-circuit current, required Ics duty, coordination and panel compatibility. A 10kA label does not make the breaker suitable for every board or fault level.

What is the difference between a 10kA and 6kA plug-in breaker?

The stated short-circuit duty differs, and Icu/Ics values may also differ. Compare the complete verified product data and receiving-panel requirements rather than treating the devices as interchangeable.

Which is better, a plug-in or bolt-on breaker?

The correct mounting style is the one approved for the receiving assembly. FB2H-63 uses plug-in mounting; a bolt-on breaker follows a different mechanical and connection design.

Are 10kA plug-in circuit breakers safe?

They can be suitable when their electrical ratings, base or panel interface and installation instructions all match the application. Product current, curve and breaking capacity alone are not enough to establish compatibility.

Do plug-in circuit breakers go bad after ten years?

There is no universal ten-year failure rule. Condition, loading, temperature, connection quality and fault history matter; damaged, overheated or unreliable equipment should be assessed by qualified personnel.

Confirm the Right FB2H-63 Configuration

Send your current rating, pole arrangement, trip option, system voltage, prospective fault level, destination market and quantity. CHAC will review the request against the published product range.

Request a Quote