Fabricante OEM de Disjuntor de Caixa Moldada (MCCB) Padrão CQM6

O CQM6 MCCB provides overload and short-circuit protection within its published 10–1250A range. Specification should follow the system voltage, load, conductor coordination, prospective fault current and applicable rules—not the ampere value alone.

Polacos:
2P / 3P / 4P
Corrente Nominal:
10–1250A
Tensão Nominal:
AC 400/415V
Trip / Protection:
overload and short-circuit protection
Dados de Última Hora:
C/S/M/H classes up to 75kA, according to frame and ordered configuration
Normal
IEC/EN 60947-1/-2/-3/-4 and GB/T 14048 references listed on the page

Visão Geral do Produto

CQM6 is a mccb breaker for AC 400/415V distribution and protection applications. Its published range covers 10–1250A with 2P / 3P / 4P options. Selection depends on the complete power-system design, including fault level, coordination, conductor ampacity, enclosure conditions and local rules.

The saved model record lists IEC/EN 60947-1/-2/-3/-4 and GB/T 14048 references listed on the page as the applicable standard reference. No certification claim is added beyond the model record.

Principais Características

  • Published current range: 10–1250A.
  • Pole options: 2P / 3P / 4P.
  • Protection function: overload and short-circuit protection.
  • Trip or setting information: thermal-magnetic trip.
  • Short-circuit data: C/S/M/H classes up to 75kA, according to frame and ordered configuration.
  • Electrical reference: AC 400/415V.
  • Accessories, terminals and installation details must be confirmed for the ordered frame and configuration.

Aplicações Típicas

Typical applications include commercial, industrial and infrastructure distribution or motor circuits. These are evaluation contexts rather than universal approvals. Confirm the exact frame, voltage, breaking duty, trip unit, accessories and installation method before specification.

Guia de Candidaturas e Seleção

Use the verified CQM6 values below to create a shortlist, then validate the complete circuit. An MCCB rating does not replace conductor calculations, fault-current analysis, coordination review or local installation requirements.

Ponto de seleção CQM6 reference O que o projeto deve confirmar
Corrente nominal 10–1250A Design current, conductor ampacity, installation method, temperature and grouping
Tensão AC 400/415V Sistema de alimentação e classificação de equipamento
Polacos 2P / 3P / 4P Live conductors and neutral treatment
Trip / protection thermal-magnetic trip Load profile, fault response and coordination
Capacidade de corte C/S/M/H classes up to 75kA, according to frame and ordered configuration Prospective short-circuit current at the installation point

Fixed vs Adjustable Protection

A fixed thermal-magnetic device can suit a stable design, while an adjustable trip unit may help coordination when the project study requires field settings.

Trip Coordination
Compare MCCB Options →

MCCB vs MCB

An MCCB is normally evaluated for higher current, fault duty or accessory flexibility; an MCB may be more suitable for compact final circuits.

Current & Fault Duty
Compare MCCB and MCB →

Icu vs Ics

The saved data for CQM6 lists C/S/M/H classes up to 75kA, according to frame and ordered configuration. Match the declared duty to the prospective short-circuit current and continuity objective.

Short-Circuit Study
Review Technical Support →

Pole and Neutral Arrangement

Published pole options are 2P / 3P / 4P. Confirm which conductors must be switched, protected and isolated together.

System Arrangement
View MCCB Range →

Guia de Encomenda

  1. State the exact model: CQM6.
  2. Provide frame and rated current within the published range: 10–1250A.
  3. Confirm poles: 2P / 3P / 4P.
  4. Specify the trip unit or protection function: thermal-magnetic trip.
  5. Provide system voltage, frequency, application, expected fault level, destination market and quantity.
  6. List required accessories, terminals, documents and any approved OEM/ODM marking or packaging requirements.

Verificações de Instalação e Coordenação

  • Use the exact model drawing and instructions; do not infer terminal positions, supply direction or accessory compatibility from another MCCB.
  • Verify conductor material and cross-section against the circuit calculation, terminal data, temperature and grouping.
  • Confirm Icu/Ics or DC fault duty, upstream/downstream coordination, enclosure conditions, altitude and clearances.
  • Installation, isolation, testing and maintenance must be performed by qualified personnel under applicable rules.

Accessory List

 

1.Our company can provide three new products for customers to choose from,namely the right-sideauxilary switch,the left-side shunt trip device,and the left-side undervoltage release device.

2.For the spedfcations of 220,320,240,340,270 and 370,the auxilaryswitcch can provide two pairs ofswitches.Please specily this vhen placing an order.

3.For the 250 and 350 specifications,the shunt trip device and undervoltage release for models 400 andabove can only be installed on 3-pole circuit breakers.

Guia de Seleção

Product code ① Shell frame grade ② Breaking capacity ③ Operating method ④ The number of poles ⑤
CQM6 125 C P 4
Molded case circuit breaker     C S M H P: Motorized operation
Z: Timing handle
W: Direct operation
2-pole
3-pole
4-pole
125 125 15/18 25/18 / /
160 160 25/18 35/25 50/35 /
250 250 25/18 35/25 50/35 /
630 630 / 35/25 50/35 70/50
800 800 / 35/25 50/35 70/50
1250 1250 / 35/25 50/35 70/50
Decoupler method and internal accessories ⑥ Rated current A ⑦ Function ⑧ Optional code for four-pole products ⑨ Special code ⑩
300 125A 2 A I
The first digit indicates the type of detent
2: Instantaneous detent only
3: Duplicate detent   Note: The last two digits are the accessory designator (see accessory table).
125 10,16,20,32,40,50,63,80,100,125 1:For power distribution
2:For motor protection
A:N-pole is unprotected and cannot be combined
B:N-pole is unprotected and can be combined
C:N-pole is protected and can be combined
D:N-pole is protected and cannot be combined
I: Overload alarm non-trip function
160 10,16,20,32,40,50,63,80,100,125,140,160
250 100,125,140,160,180,200,225,250
630 250,315,350,400,500,630
800 500,630,700,800
1250 800,1000,1250
Accessory Voltage ⑪ Motorized operating voltage ⑫ Installation ⑬ Whether to install a terminal block ⑭
Q1 D1 Q 2
Undervoltage detent
Q1:AC220V
Q2:AC240V
Q3:AC380V
Q4:AC415V
Shunt release
F1:AC220V
F2:AC380V
F3:DC110V
F4:DC24V
Auxiliary alarm
J1:AC125V
J2:AC250V
J3:DC125V
J4:DC24V
DC1 Electrical Operation
D1:AC220V
D2:AC230V
D3:AC380V
D4:AC400V
DC3 Electrical Operation
D5:AC230V
D6:AC110V
D7:DC220
D8:DC110
D9:AC110~240V
D10:DC100~220V
Q:Front of plate
H:Rear of plate
C:Inserted
1:No installation
2:Installation
Note:When motorized operation is selected,please refer to the external accessories for the two voltages applicable for motorized operation.

Main Technical Parameters

Número do modelo CQM6-125 CQM6-160
Rated current of frame level Inm(A) 125 160
Número de polos 2, 3, 4 3, 4
Rated current In(A),at 40℃,50℃,55℃ 10,16,20,25,32,40,50,63,80,100,125 10,16,20,25,32,40,50,63,80,100,125,140,160
Rated operating voltage Ue(V),AC 50/60Hz 400/415 400/415
Rated insulation voltage Ui (V) 800 800
Rated impulse withstand voltage Uimp(KV) 8 8
Breaking capacity designation C S   C S M
Short-circuit breaking capacity Icu/Ics(kA) AC400/415V 46249 25/18   25/18 35/25 50/35
Selectivity category A A   A A A
Number of operating cycles(cycle) ON 6000 6000
OFF 10000 10000
Trip mechanisms and protection types Magnetic trip Power distribution protection
Motor protection
Thermal-magnetic trip Power distribution protection
Motor protection
Accessory Auxiliary contacts
Alarm contacts
Shunt disconnect
Undervoltage detent
Manual operating mechanism
Motorized operating mechanism
Backplane wiring
Inserted
Coupling plate
Partition between phases
Derivative products Dedicated for prepayment electric meters
Overload alarm without trip
Overall dimensions
(mm) (a-b-c-ca)
3 P 75-130-68-92 90-155-70-94 90-155-84-109
4 P 100-130-68-92 120-155-70-94 120-155-84-109

Note:● for optional accessories;”-” for no optional accessories.

Main Technical Parameters

Número do modelo CQM6-250 CQM6-630
Rated current of frame level Inm(A) 250 630
Número de polos 2, 3, 4 3, 4
Rated current In(A),at 40℃,50℃,55℃ 125,140,160,180,200,225,250 250,315,350,400,500,630
Rated operating voltage Ue(V),AC 50/60Hz 400/415 400/415
Rated insulation voltage Ui (V) 800 800
Rated impulse withstand voltage Uimp(KV) 8 8
Breaking capacity designation C S M S M H
Short-circuit breaking capacity Icu/Ics(kA) AC400/415V 25/18 35/25 50/35 35/25 50/35 70/50
Selectivity category A A A A A A
Number of operating cycles(cycle) ON 6000 3000
OFF 10000 8000
Trip mechanisms and
protection types
Magnetic trip Power distribution protection
Motor protection
Thermal-magnetic trip Power distribution protection
Motor protection
Accessory Auxiliary contacts
Alarm contacts
Shunt disconnect
Undervoltage detent
Manual operating mechanism
Motorized operating mechanism
Backplane wiring
Inserted
Coupling plate
Partition between phases
Derivative products Dedicated for prepayment electric meters
Overload alarm without trip
Overall dimensions
(mm) (a-b-c-ca)
3 P 105-165-70-96 105-165-93-120 140-257-105-155
4 P 140-165-70-96 140-165-93-120 185-257-105-155

Note:● for optional accessories;”-” for no optional accessories.

Main Technical Parameters

Número do modelo CQM6-800 CQM6-1250
Rated current of frame level Inm(A) 800 1250
Número de polos 3, 4 3, 4
Rated current In(A),at 40℃,50℃,55℃ 500, 630, 700, 800 1000, 1250
Rated operating voltage Ue(V),AC 50/60Hz 400/415 400/415
Rated insulation voltage Ui (V) 800 800
Rated impulse withstand voltage Uimp(KV) 8 8
Breaking capacity designation S M H S M H
Short-circuit breaking capacity Icu/Ics(kA) AC400/415V 35/25 50/35 70/50 35/25 50/35 70/50
Selectivity category A A A A A A
Number of operating cycles(cycle) ON 3000 1000
OFF 8000 3000
Trip mechanisms and protection types Magnetic trip Power distribution protection
Motor protection
Thermal-magnetic trip Power distribution protection
Motor protection
Accessory Auxiliary contacts
Alarm contacts
Shunt disconnect
Undervoltage detent
Manual operating mechanism
Motorized operating mechanism
Backplane wiring
Inserted
Coupling plate
Partition between phases
Derivative products Dedicated for prepayment electric meters
Overload alarm without trip
Overall dimensions
(mm) (a-b-c-ca)
3 P 210-275-105-155 210-275-105-155
4 P 280-275-105-155 280-275-105-155

Note:● for optional accessories;”-” for no optional accessories.

Operating Characteristics

1.The inverse time operating characteristics of power distribution circuit when all poles areenergized simultaneously at anambient air temperature of +40℃(with no humidity compensation)are shown in the following table:

Test current designation Setting current multiple Conventional time Initial state
    In≤63 63<In  
Conventional non-tripping current 1.05 ≥1h ≥2h Cool state
Conventional tripping current 1.3 <1h <2h Hot state

2.The inverse time action characteristics of circuit breakers for motor ption without humiditycompensation when all poles areenergized simultaneously at an ambient air temperature of+40C are showrin the following table.

Test current designation Setting current multiple Conventional time Initial state
    In≤800  
Conventional non-tripping current 1 ≥2h Cool state
Conventional tripping current 1.2 <2h Hot state

3.Action characteristics under short-circuit condition:The short-circuuit curent setting value ofthe instantaneous tripper of the circuitbreaker forpower distribution is 10ln.

The short-circuit current setting value of the instantaneous tripper of the circuit breaker for motorprotection is 12ln.

The accuracy of the short-circuit curent setting value of the instantaaneous tripper is 20% of the short-circuit currentsetting value.

CQM6-125 Operating Characteristic Curve

CQM6-160 Operating Characteristic Curve

CQM6-250 Operating Characteristic Curve

CQM6-630 Operating Characteristic Curve

CQM6-800 Operating Characteristic Curve

CQM6-1250 Operating Characteristic Curve

Outline and Installation Dimensions(mm)

Outline and Installation Dimensions(mm)

Molded case circuit breaker Overall dimension Installation dimensions Bolt
A A1 A2 A3 B B1 B2 B3 B5 B6 H H1 H2 H3 H4 H5 H6 A4 B4
3P 4P 3P 4P 3P 4P 3P 4P                              
CQM6-125CS 75 100 50 75 130 114 85 50 50 92 72 4 68 61 41 24 25 111 M8/M6
CQM6-160CS 90 120 60 90 155 134 103 50 50 94 72 4 70 61 41 24 30 132 M8
CQM6-160M 90 120 60 90 155 134 103 50 50 109 83 4 83 76 24.5 24.5 30 132 M8
CQM6-250CS 105 140 70 105 165 144 103 50 100 96 72 4 70 61 46 24 35 126 M8
CQM6-250M 105 140 70 105 165 144 102 50 110 120 95 4 91 84 22.5 24 35 126 M8
CQM6-630SMH 140 185 88 132 140 196 112 168 257 230 179 90 110 42 155 107 5 105 97 64 35 44 194 M10
CQM6-800SMH 210 280 140 210 180 250 140 210 275 243 192 90 110 87 155 107 5 104 97 65 24 70 242.5 M12
CQM6-1250SMH 210 280 140 210 180 250 140 210 275 243 192 90 110 87 155 107 5 104 97 65 24 70 242.5 M10*2

Porquê escolher a CHAC

Com mais de 30 anos de experiência em fabrico, mais de 1100 funcionários, mais de 100 milhões de postes
Com uma capacidade anual e um processo de produção automatizado 90%, a CHAC garante uma capacidade de produção estável e rigorosos
Controlo de qualidade para clientes OEM/ODM globais. O nosso sistema de fabrico interno suporta a longo prazo
cooperação para marcas elétricas, importadores e distribuidores.


30+

ANOS DE EXPERIÊNCIA

Especializado em fabrico de baixa tensão elétrica


1100+

FUNCIONÁRIOS

Equipa profissional garante qualidade e entrega estáveis


100M+

CAPACIDADE ANUAL DE POSTOS

Capacidade de produção em larga escala para satisfazer a procura global


90%

PRODUÇÃO AUTOMATIZADA

Automação avançada para alta eficiência e consistência

Linha de Montagem Automatizada

Linha de Montagem Automatizada

Laboratório de Ensaios

Laboratório de Ensaios

Injeção e Estampagem

Injeção e Estampagem

Inspeção de Qualidade

Inspeção de Qualidade

Certificação IEC
Certificação CE
Certificação CB
Certificação RoHS
Certificação ISO 14001

Um rigoroso sistema de controlo de qualidade garante que cada produto cumpre as normas globais.

O que podemos personalizar?

For CQM6 projects, CHAC can review private-label marking, packaging, approved appearance options, published 10–1250A electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, minimum order quantity and project feasibility.

Design de Caixa

Recinto
Design

Tamanhos de caixas personalizadas, estruturas e detalhes de instalação.

Design de Caixa

Configuração Interna

Interno
Configuração

Layout interno flexível e opções de arranjo de componentes.

Configuração Interna

Branding e Logótipo

Branding &
Logótipo

Logótipos de marca própria, placas de identificação e identificação da marca.

Branding e Logótipo

Design de Embalagem

Embalagem
Design

Caixas personalizadas, etiquetas, manuais e soluções de embalagem.

Design de Embalagem

Configuração Elétrica

Elétrico
Configuração

Instalação elétrica à medida com base nos requisitos da aplicação.

Configuração Elétrica

Suporte de Certificação

Certificação
Apoio

Apoio a normas e requisitos de conformidade do mercado-alvo.

Suporte de Certificação

Transferir

PDF

Disjuntor de Caixa Moldada Série CQM6

Visão geral completa de componentes elétricos de baixa tensão e referência para seleção de produtos.

Transferir PDF

SUP

Precisa de Documentos Técnicos?

Contacte-nos para folhas de dados, certificados, desenhos, orientação de seleção ou suporte a projetos OEM/ODM.

Contacte-nos

CQM6 Product FAQ

What is the CQM6 MCCB used for?

The CQM6 is specified for overload and short-circuit protection in AC 400/415V systems within the published 10–1250A range. Suitability depends on the fault study, conductor coordination, enclosure and local rules.

How does the CQM6 molded case circuit breaker work?

The protection mechanism responds to the fault conditions stated for this model: overload and short-circuit protection. Trip behaviour, settings and interruption duty must be checked against the ordered frame and product instructions.

How do I choose the CQM6 rated current and poles?

Start with the design current and conductor calculation, then choose a published current within 10–1250A and poles from 2P / 3P / 4P. Neutral treatment, fault level, ambient conditions and coordination also need review.

What breaking capacity should I check on the CQM6?

Use the declared C/S/M/H classes up to 75kA, according to frame and ordered configuration for the exact frame, voltage and configuration. The prospective short-circuit current at the installation point must be within the applicable duty; a larger ampere value alone is not a selection rule.

Can the CQM6 replace an MCB or an earth-leakage device?

An MCCB is not automatically a like-for-like replacement. The CQM6 provides overload and short-circuit protection; residual-current protection, DC interruption, adjustable settings and other functions must be confirmed separately from the project requirement.

How should the CQM6 be installed and tested?

Use only the exact model drawing, terminal identification and accessory instructions. A qualified person should verify isolation, conductor size, torque, clearances, settings, fault duty and functional tests before energising the circuit.

Confirm the Right CQM6 Configuration

Send the frame, rated current, poles, protection function, system voltage, expected fault level, destination market and quantity. CHAC will review the request against the published model range.

Pedir um orçamento