CQM6 Standard Molded Case Circuit Breaker (MCCB) OEM Manufacturer
The CQM6 MCCB provides overload and short-circuit protection within its published 16–1600A range. Specification should follow the system voltage, load, conductor coordination, prospective fault current and applicable rules—not the ampere value alone.
Product Overview
CQM6 is a mccb breaker for AC distribution and protection applications. Its published range covers 16–1600A with 2P / 3P / 4P, depending on frame; CQM6-1600: 3P options. Selection depends on the complete power-system design, including fault level, coordination, conductor ampacity, enclosure conditions and local rules.
The supplied product specification references IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-3 and IEC/EN 60947-4, together with GB/T 14048.1, .2, .3 and .4. These standard references do not, by themselves, establish certification for a particular order.
Key Features
Typical Applications
Typical applications include commercial, industrial and infrastructure distribution or motor circuits. These are evaluation contexts rather than universal approvals. Confirm the exact frame, voltage, breaking duty, trip unit, accessories and installation method before specification.
Applications and Selection Guide
Use the verified CQM6 values below to create a shortlist, then validate the complete circuit. An MCCB rating does not replace conductor calculations, fault-current analysis, coordination review or local installation requirements.
| Selection point | CQM6 reference | What the project must confirm |
|---|---|---|
| Rated current | 16–1600A | Design current, conductor ampacity, installation method, temperature and grouping |
| Voltage | AC 400/415V; CQM6-1600 also lists 660/690V configurations | Supply system and equipment rating |
| Poles | 2P / 3P / 4P, depending on frame; CQM6-1600: 3P | Live conductors and neutral treatment |
| Trip / protection | thermal-magnetic trip | Load profile, fault response and coordination |
| Breaking capacity | C/S/M/H/L classes, with Icu up to 100kA for the listed CQM6-1600 660/690V configurations; verify the exact frame and voltage | Prospective short-circuit current at the installation point |
Fixed vs Adjustable Protection
A fixed thermal-magnetic device can suit a stable design, while an adjustable trip unit may help coordination when the project study requires field settings.
Trip Coordination
Compare MCCB Options →
MCCB vs MCB
An MCCB is normally evaluated for higher current, fault duty or accessory flexibility; an MCB may be more suitable for compact final circuits.
Current & Fault Duty
Compare MCCB and MCB →
Icu vs Ics
The saved data for CQM6 lists C/S/M/H/L classes, with Icu up to 100kA for the listed CQM6-1600 660/690V configurations; verify the exact frame and voltage. Match the declared duty to the prospective short-circuit current and continuity objective.
Short-Circuit Study
Review Technical Support →
Pole and Neutral Arrangement
Published pole options are 2P / 3P / 4P, depending on frame; CQM6-1600: 3P. Confirm which conductors must be switched, protected and isolated together.
System Arrangement
View MCCB Range →
Ordering Guide
- State the exact model: CQM6.
- Provide frame and rated current within the published range: 16–1600A.
- Confirm poles: 2P / 3P / 4P, depending on frame; CQM6-1600: 3P.
- Specify the trip unit or protection function: thermal-magnetic trip.
- Provide system voltage, frequency, application, expected fault level, destination market and quantity.
- List required accessories, terminals, documents and any approved OEM/ODM marking or packaging requirements.
Installation and Coordination Checks
- Use the exact model drawing and instructions; do not infer terminal positions, supply direction or accessory compatibility from another MCCB.
- Verify conductor material and cross-section against the circuit calculation, terminal data, temperature and grouping.
- Confirm Icu/Ics or DC fault duty, upstream/downstream coordination, enclosure conditions, altitude and clearances.
- Installation, isolation, testing and maintenance must be performed by qualified personnel under applicable rules.
Selection Guide

| Product code ① | Extension Code ② | Shell frame grade ③ | Breaking capacity ④ | Operating method ⑤ | Number of poles ⑥ | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| CQM6 | G | 125 | C | P | 4 | |||||
| Molded case circuit breaker | —:Thermal and magnetic protection are not adjustable G:Overload alarm without trip function |
C | S | L | M | H | P:Motorized operation Z:Turning handle W.Direct operation |
125A:2P,3P,4P 160A:3P,4P 250A:2P,3P,4P 400A:3P,4P 630A:3P,4P 800A:3P,4P 1250A:3P,4P 1600A:3P |
||
| 125 | 125 | 15/8 | 25/18 | / | / | / | ||||
| 160 | 160 | 25/18 | 35/25 | / | 50/35 | / | ||||
| 250 | 250 | 25/18 | 35/25 | / | 50/35 | / | ||||
| 400 | 400 | / | 35/25 | / | 50/35 | 70/50 | ||||
| 630 | 630 | / | 35/25 | / | 50/35 | 70/50 | ||||
| 800 | 800 | / | 35/25 | / | 50/35 | 70/50 | ||||
| 1250 | 1250 | / | / | / | 50/35 | 70/55 | ||||
| 1600 | 1600 | / | / | 70/20 | 100/35 | 100/50 | ||||
| Trip Unit &Accessories ⑦ | Rated current A ⑧ | Function ⑨ | 4P Option Code ⑩ | Special code ⑪ | |
|---|---|---|---|---|---|
| 300 | 125A | 2 | A | I | |
| The first digit indicates the type of detent 2:instantaneous detent only 3:Duplicate detent Note:The last two digits are the accessory designator(see accessory table). |
125 | 16,20,32,40,50,63,80,100,125 | 1:For power distribution 2:For motor protection |
A:N-pole is unprotected and cannot be combined B:N-pole is unprotected and can be combined C:N-pole is protected and can be combined D:N-pole is protected and cannot be combined |
I:Overload alarm non trip function |
| 160 | 16,20,32,40,50,63,80,100,125,140,160 | ||||
| 250 | 100,125,140,160,180,200,225,250 | ||||
| 400 | 250,315,350,400 | ||||
| 630 | 250,315,350,400,500,630 | ||||
| 800 | 500,630,700,800 | ||||
| 1250 | 800,1000,1250 | ||||
| 1600 | 800,1000,1250,1400,1500,1600 | ||||
| Accessory Voltage ⑫ | Motorized operating voltage ⑬ | Installation ⑭ | Terminal Block Option ⑮ | |||
|---|---|---|---|---|---|---|
| Q1 | D1 | Q | 2 | |||
| Undervoltage detent Q1:AC220V Q2:AC240V Q3:AC380V Q4:AC415V | Shunt release F1:AC220V F2:AC380V F3:DC110V F4:DC24V | Auxiliary alarm J1:AC125V J2:AC250V J3:DC125V J4:DC24V | CD1 Electrical Operation D1:AC220V D2:AC230V D3:AC380V D4:AC400V |
CD2 Electrical Operation D5:AC230V D6:AC110V D7:DC220 D8:DC110 D9:AC110–240V D10:DC100–220V | Q:Front of plate H:Rear of plate C:Inserted | 1:Noinstitution 2:Installation |
| Note:When motorized operation is selected,please refer to the external accessories for the two voltages applicable for motorized operation. | ||||||
Accessory List


CHAC offers a right-side auxiliary switch, a left-side shunt release and a left-side undervoltage release.
For accessory codes 220, 320, 240, 340, 270 and 370, the auxiliary switch can provide two contact pairs. Specify this requirement when ordering.
For accessory codes 250 and 350, the shunt release and undervoltage release on frames 400 and above are available only for 3-pole circuit breakers.
Main Technical Parameters
| Model number | CQM6-125 | CQM6-160 | |||||
|---|---|---|---|---|---|---|---|
| Rated current of frame level Inm(A) | 125 | 160 | |||||
| Number of poles | 2,3,4 | 3,4 | |||||
| Rated current In(A),at 40°C,50°C,55°C | 16,20,25,32,40,50,63,80,100,125 | 16,20,25,32,40,50,63,80,100,125,140,160 | |||||
| Rated operating voltage Ue(V),AC 50/60Hz | 400/415 | 400/415 | |||||
| Rated insulation voltage Ui (V) | 800 | 800 | |||||
| Rated impulse withstand voltage Uimp(KV) | 8 | 8 | |||||
| Breaking capacity designation | C | S | C | S | M | ||
| Short-circuit breaking capacity Icu/Ics(kA) | AC400/415V | 15/8 | 25/18 | 25/18 | 35/25 | 50/35 | |
| Selectivity category | A | A | A | A | A | ||
| Number of operating cycles(cycle) | ON | 6000 | 6000 | ||||
| OFF | 10000 | 10000 | |||||
| Trip mechanisms and protection types | Magnetic trip | Power distribution protection | ● | ● | ● | ● | ● |
| Motor protection | ● | ● | ● | ● | ● | ||
| Thermal-magnetic trip | Power distribution protection | ● | ● | ● | ● | ● | |
| Motor protection | ● | ● | ● | ● | ● | ||
| Accessory | Auxiliary contacts | ● | ● | ● | ● | ● | |
| Alarm contacts | ● | ● | ● | ● | ● | ||
| Shunt disconnect | ● | ● | ● | ● | ● | ||
| Undervoltage detent | ● | ● | ● | ● | ● | ||
| Manual operating mechanism | ● | ● | ● | ● | ● | ||
| Motorized operating mechanism | ● | ● | ● | ● | ● | ||
| Backplane wiring | ● | ● | ● | ● | ● | ||
| Inserted | ● | ● | ● | ● | ● | ||
| Coupling plate | ● | ● | ● | ● | ● | ||
| Partition between phases | ● | ● | ● | ● | ● | ||
| Derivative products | Dedicated for prepayment electric meters | ● | ● | ● | ● | ● | |
| Overload alarm without trip | – | – | ● | ● | ● | ||
| Overall dimensions (mm) (a–b–c–ca) | ![]() |
3 P | 75×130×68×91 | 90×155×70×95 | 90×155×85 ×109 | ||
| 4 P | 100×130×68×91 | 120×155×70×95 | 120×155×85 ×109 | ||||
Note: ● indicates an available optional accessory; – indicates that the accessory is not available.
Main Technical Parameters
| Model number | CQM6-250 | CQM6-400 | CQM6-630 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Rated current of frame level Inm(A) | 250 | 400 | 630 | ||||||||
| Number of poles | 2,3,4 | 3,4 | 3,4 | ||||||||
| Rated current In(A),at 40°C,50°C,55°C | 100,125,140,160,180,200,225,250 | 250,315,350,400 | 250,315,350,400,500,630 | ||||||||
| Rated operating voltage Ue(V),AC 50/60Hz | 400/415 | 400/415 | 400/415 | ||||||||
| Rated insulation voltage Ui (V) | 800 | 800 | 800 | ||||||||
| Rated impulse withstand voltage Uimp(KV) | 8 | 8 | 8 | ||||||||
| Breaking capacity designation | C | S | M | S | M | H | S | M | H | ||
| Short-circuit breaking capacity Icu/Ics(kA) | AC400/415V | 25/18 | 35/25 | 50/35 | 35/25 | 50/35 | 70/50 | 35/25 | 50/35 | 70/50 | |
| Selectivity category | A | A | A | A | A | A | A | A | A | ||
| Number of operating cycles (cycle) |
ON | 6000 | 3000 | 3000 | |||||||
| OFF | 10000 | 8000 | 8000 | ||||||||
| Trip mechanisms and protection types | Magnetic trip | Power distribution protection | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| Motor protection | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Thermal-magnetic trip | Power distribution protection | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| Motor protection | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Accessory | Auxiliary contacts | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| Alarm contacts | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Shunt disconnect | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Undervoltage detent | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Manual operating mechanism | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Motorized operating mechanism | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Backplane wiring | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Inserted | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Coupling plate | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Partition between phases | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Derivative products | Dedicated for prepayment electric meters | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| Overload alarm without trip | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Overall dimensions (mm) (a-b-c-ca) | ![]() |
3 P | 105×165×70×95 | 105×165×93×118 | 140×257×107×156 | 140×257×107×156 | |||||
| 4 P | 140×165×70×95 | 140×165×93×118 | 185×257×107×156 | 185×257×107×156 | |||||||
Note: ● indicates an available optional accessory; – indicates that the accessory is not available.
Main Technical Parameters
| Model number | CQM6-800 | CQM6-1250 | CQM6-1600 | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Rated current of frame level Inm(A) | 800 | 1250 | 1600 | |||||||
| Number of poles | 3,4 | 3,4 | 3 | |||||||
| Rated current In(A),at 40°C,50°C,55°C | 500,630,700,800 | 800,1000,1250 | 800,1000,1250,1400,1500,1600 | |||||||
| Rated operating voltage Ue(V),AC 50/60Hz | 400/415 | 400/415 | 400/415V | 660/690V | ||||||
| Rated insulation voltage Ui (V) | 800 | 1000 | 1000 | |||||||
| Rated impulse withstand voltage Uimp(KV) | 8 | 12 | 12 | |||||||
| Breaking capacity designation | S | M | H | M | H | L | M | H | ||
| Short-circuit breaking capacity Icu/Ics(kA) | AC400/415V | 35/25 | 50/35 | 70/50 | 50/35 | 70/55 | 70/20 | 100/35 | 100/50 | |
| Selectivity category | A | A | A | A | A | A | A | A | ||
| Number of operating cycles (cycle) |
ON | 1000 | 1000 | 500 | ||||||
| OFF | 3000 | 3000 | 3000 | |||||||
| Trip mechanisms and protection types | Magnetic trip | Power distribution protection | ● | ● | ● | ● | ● | ● | ● | ● |
| Motor protection | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Thermal-magnetic trip | Power distribution protection | ● | ● | ● | ● | ● | ● | ● | ● | |
| Motor protection | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Accessory | Auxiliary contacts | ● | ● | ● | ● | ● | ● | ● | ● | |
| Alarm contacts | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Shunt disconnect | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Undervoltage detent | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Manual operating mechanism | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Motorized operating mechanism | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Backplane wiring | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Inserted | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Coupling plate | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Partition between phases | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Derivative products | Dedicated for prepayment electric meters | ● | ● | ● | ● | ● | ● | ● | ● | |
| Overload alarm without trip | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Overall dimensions (mm) (a–b–c–ca) | ![]() |
3 P | 210×275×113×162 | 210×275×113×162 | 210×268×161×240 | |||||
| 4 P | 280×275×113×162 | 280×275×113×162 | ||||||||
Note: ● indicates an available optional accessory; – indicates that the accessory is not available.
Operating Characteristics
The following table gives the inverse-time operating characteristics for distribution protection with all poles energised at an ambient temperature of +40°C, without humidity compensation.
| Test current designation | Setting current multiple | Conventional time | Initial state |
|---|---|---|---|
| In≤63 63<In | |||
| Conventional non-tripping current | 1.05 | ≥1h ≥2h | Cool state |
| Conventional tripping current | 1.30 | <1h <2h | Hot state |
The following table gives the inverse-time operating characteristics for motor protection with all poles energised at an ambient temperature of +40°C, without humidity compensation.
| Test current designation | Setting current multiple | Conventional time | Initial state |
|---|---|---|---|
| In≤800 | |||
| Conventional non-tripping current | 1.0 | ≥2h | Cool state |
| Conventional tripping current | 1.2 | <2h | Hot state |
The operating-characteristics reference gives an instantaneous trip current setting of 10In for distribution protection. Confirm the applicable trip-unit setting for the ordered configuration.
The operating-characteristics reference gives an instantaneous trip current setting of 12In for motor protection.
The stated accuracy of the instantaneous trip current setting is 20% of the setting value.
CQM6-125 Operating Characteristic Curve

CQM6-160 Operating Characteristic Curve

CQM6-250 Operating Characteristic Curve

CQM6-400 / 630 Operating Characteristic Curve

CQM6-800 Operating Characteristic Curve

CQM6-1250 Operating Characteristic Curve

CQM6-125~1250 Outline and Installation Dimensions(mm)

CQM6-1600 Outline and Installation Dimensions(mm)

| Molded case circuit breaker | Overall dimension | Installation dimensions | Boit | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A | A1 | A2 | A3 | B | B1 | B2 | B3 | B5 | B6 | H | H1 | H2 | H3 | H4 | H5 | H6 | A4 | B4 | ||||||
| 3P | 4P | 3P | 4P | 3P | 4P | 3P | 4P | |||||||||||||||||
| CQM6-125CSM | 75 | 100 | 50 | 75 | – | – | – | – | 130 | 114 | 85 | 50 | 48 | – | 91 | 73.4 | 2.4 | 68 | 61 | 23.9 | 24 | 25 | 111 | M6 |
| CQM6-160CS | 90 | 120 | 60 | 90 | – | – | – | – | 155 | 134 | 103 | 50 | 48 | – | 95 | 75.5 | 2.1 | 70 | 62 | 24 | 24.8 | 30 | 132 | M8 |
| CQM6-160M | 90 | 120 | 60 | 90 | – | – | – | – | 155 | 134 | 103 | 50 | 48 | – | 109.5 | 90 | 2.1 | 85 | 76.5 | 23.6 | 25 | 30 | 132 | M8 |
| CQM6-250CS | 105 | 140 | 70 | 105 | – | – | – | – | 165 | 144 | 102 | 50 | 97 | – | 95 | 74.2 | 2.7 | 70 | 61.4 | 22.3 | 23.1 | 35 | 126 | M8 |
| CQM6-250M | 105 | 140 | 70 | 105 | – | – | – | – | 165 | 144 | 102 | 50 | 95 | – | 118.5 | 97.7 | 2.7 | 93.4 | 84.8 | 22.9 | 23.3 | 35 | 126 | M8 |
| CQM6-400SMH | 140 | 185 | 70 | 132 | 140 | 196 | 112 | 168 | 257 | 230 | 179 | 90 | 103 | 42 | 156 | 111.7 | 3.5 | 107.5 | 99.5 | 30.9 | 32.4 | 44 | 194 | M10 |
| CQM6-630SMH 400A | 140 | 185 | 88 | 132 | 140 | 196 | 112 | 168 | 257 | 230 | 179 | 90 | 103 | 42 | 156 | 111.7 | 3.5 | 107.5 | 99.5 | 30.9 | 32.4 | 44 | 194 | M10 |
| CQM6-630SMH 630A | 140 | 185 | 88 | 132 | 140 | 196 | 112 | 168 | 257 | 230 | 179 | 90 | 103 | 42 | 156 | 111.7 | 3.5 | 107.5 | 99.5 | 33.2 | 34 | 44 | 194 | M10 |
| CQM6-800SMH 630A | 210 | 280 | 140 | 210 | 180 | 250 | 140 | 210 | 275 | 243 | 192 | 90 | 103 | 87 | 162.5 | 118 | 2.7 | 113.4 | 105.5 | 28.3 | 30.4 | 70 | 242.5 | M12 |
| CQM6-800SMH 800A | 210 | 280 | 140 | 210 | 180 | 250 | 140 | 210 | 275 | 243 | 192 | 90 | 103 | 87 | 162.5 | 118 | 2.7 | 113.4 | 105.5 | 29 | 32.6 | 70 | 242.5 | M12 |
| CQM6-1250SMH | 210 | 280 | 140 | 210 | 180 | 250 | 140 | 210 | 275 | 243 | 192 | 90 | 103 | 87 | 162.5 | 118 | 2.7 | 113.4 | 105.5 | 31.3 | 34.4 | 70 | 242.5 | M10 |
| CQM6-1600LMH | 210 | – | 140 | – | – | – | – | – | 268 | 240 | 118 | 97 | 110 | – | 240 | 171 | 5 | 161 | 150 | 33 | 34 | 70 | 245.0 | M10 |
Why Choose CHAC
With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.
30+
YEARS EXPERIENCE
Specialized in low-voltage electrical manufacturing
1100+
EMPLOYEES
Professional team ensures stable quality and delivery
100M+
POLES ANNUAL CAPACITY
Large-scale production capacity to meet global demand
90%
AUTOMATED PRODUCTION
Advanced automation for high efficiency and consistency

Automated Assembly Line

Testing Laboratory

Injection & Stamping

Quality Inspection





Strict quality control system ensures every product meets global standards.
What Can We Customize?
For CQM6 projects, CHAC can review private-label marking, packaging, approved appearance options, published 16–1600A electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, minimum order quantity and project feasibility.
Enclosure
Design
Customized enclosure sizes, structures and installation details.
Internal
Configuration
Flexible internal layout and component arrangement options.
Branding &
Logo
Private label logos, nameplates and brand identification.
Packaging
Design
Custom cartons, labels, manuals and packaging solutions.
Electrical
Configuration
Tailored electrical setup based on application requirements.
Certification
Support
Support for target-market standards and compliance requirements.
Download
CQM6 Series Moulded Case Circuit Breaker
Complete product overview for low-voltage electrical components and product selection reference.
Need Technical Documents?
Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.
CQM6 Product FAQ
What is the CQM6 MCCB used for?
The CQM6 is specified for overload and short-circuit protection in AC systems at the voltage listed for the ordered frame within the published 16–1600A range. Suitability depends on the fault study, conductor coordination, enclosure and local rules.
How does the CQM6 molded case circuit breaker work?
The protection mechanism responds to the fault conditions stated for this model: overload and short-circuit protection. Trip behaviour, settings and interruption duty must be checked against the ordered frame and product instructions.
How do I choose the CQM6 rated current and poles?
Start with the design current and conductor calculation, then choose a published current within 16–1600A and poles from 2P / 3P / 4P, depending on frame; CQM6-1600: 3P. Neutral treatment, fault level, ambient conditions and coordination also need review.
What breaking capacity should I check on the CQM6?
Use the declared C/S/M/H/L classes, with Icu up to 100kA for the listed CQM6-1600 660/690V configurations; verify the exact frame and voltage for the exact frame, voltage and configuration. The prospective short-circuit current at the installation point must be within the applicable duty; a larger ampere value alone is not a selection rule.
Can the CQM6 replace an MCB or an earth-leakage device?
An MCCB is not automatically a like-for-like replacement. The CQM6 provides overload and short-circuit protection; residual-current protection, DC interruption, adjustable settings and other functions must be confirmed separately from the project requirement.
How should the CQM6 be installed and tested?
Use only the exact model drawing, terminal identification and accessory instructions. A qualified person should verify isolation, conductor size, torque, clearances, settings, fault duty and functional tests before energising the circuit.
Confirm the Right CQM6 Configuration
Send the frame, rated current, poles, protection function, system voltage, expected fault level, destination market and quantity. CHAC will review the request against the published model range.