Disjuntor de Proteção de Motor da Série CQV2

O Disjuntor de Proteção de Motor da Série CQV2 is a CHAC motor protection circuit breaker for overload, phase-failure and short-circuit protection. The page keeps the model-specific technical table and original product images so buyers can verify voltage, current, configuration, mounting and applicable standards before ordering. Final suitability depends on the complete circuit, installation method and destination-market rules.

Product family:
Protetor de Motor
Primary function:
overload, phase-failure and short-circuit protection
Typical context:
three-phase motors, pumps and machine feeders
Technical data:
See verified model table below
Configuration:
Confirm the exact model variant
Support:
OEM/ODM review available

Visão Geral do Produto

CQV2 Series Motor Protection Circuit Breaker is a motor protection circuit breaker intended for overload, phase-failure and short-circuit protection. The current product record identifies it for three-phase motors, pumps and machine feeders. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.

Verified source summary: Type Designation Tripping Characteristic Curve Test condition: Ambient temperature 20℃ Curve parameters (based on multiples of setting current in): (1) Starting from cold state, 3-pole (2) Starting from cold state, 2-pole (3) Starting from hot state, 3-pole Dimensions (mm) CQV2-ME CQV-AU/AX/AS CQV-AN/AD/AM CQV-AE Circuit Shield Technical Specifications Product Model Rated current(A) Motor output(kW) Setting Range(A)

Principais Características

  • Product type: motor protection circuit breaker.
  • Primary function: overload, phase-failure and short-circuit protection.
  • Application context: three-phase motors, pumps and machine feeders.
  • Model variants, dimensions and ratings remain in the preserved technical source.
  • Confirm installation method, environmental limits and local compliance before release.

Aplicações Típicas

Typical use can include three-phase motors, pumps and machine feeders when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.

Guia de Candidaturas e Seleção

Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.

Ponto de seleção Disjuntor de Proteção de Motor da Série CQV2 O que o projeto deve confirmar
Aplicação Motor Protector projects Confirm the actual system and environment
Selection basis overload, phase-failure and short-circuit protection Use the exact model and technical table
Instalação Follow the model instructions Check mounting, clearances and termination
Compliance Use the listed standard where applicable Verify edition, scope and destination rules
Adjacent product Evaluate the related CHAC family where function differs Do not substitute without engineering review

Function

overload, phase-failure and short-circuit protection

Match the protection or switching function to the system.

View related guidance →

Configuração

Model-specific options

Confirm current, voltage, poles, terminals or accessories from the table.

View related guidance →

Instalação

Mechanical and electrical fit

Check enclosure, mounting, wiring space and maintenance access.

View related guidance →

Project evidence

Documents and test records

Retain the approved drawing, technical sheet and commissioning record.

View related guidance →

Guia de Encomenda

  1. State the exact model and variant.
  2. Provide the system voltage, current, frequency and load or protection function.
  3. Confirm mounting, terminals, accessories, enclosure and environmental conditions.
  4. Share quantity, destination market and required technical documents.

Verificações de Instalação e Coordenação

  • Verify the model’s ratings and connection arrangement against the project drawings.
  • Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
  • Coordinate upstream and downstream protection or control devices where applicable.
  • Use qualified personnel for installation, testing, isolation and maintenance.

Type Designation

Tripping Characteristic Curve

Test condition: Ambient temperature 20℃

Curve parameters (based on multiples of setting current in):

(1) Starting from cold state, 3-pole

(2) Starting from cold state, 2-pole

(3) Starting from hot state, 3-pole

Dimensões (mm)

CQV2-ME

CQV-AU/AX/AS      CQV-AN/AD/AM     CQV-AE

Circuit Shield

Especificações Técnicas

Modelo de produto Rated current(A) Motor output(kW) Setting Range(A) Order Number Packing parameters
CQV2-ME32 Thermal overload releases

Instantaneous overcurrent releases

QTY:50PCS
N.W:13.5KG
G.W:15KG
MEAS:48X27X19CM
0.16 0.04 0.1-0.16 1.9 CQV2-ME01
0.25 0.07 0.16-0.25 3 CQV2-ME02
0.4 0.09/0.12 0.25-0.4 4.8 CQV2-ME03
0.63 0.12/0.18 0.4-0.63 7.2 CQV2-ME04
1 0.25 0.63-1 12 CQV2-ME05
1.6 0.37/0.55 1-1.6 19 CQV2-ME06
2.5 0.75 1.6-2.5 30 CQV2-ME07
4 1.1/1.5 2.5-4 51 CQV2-ME08
6.3 2.2 4-6.3 78 CQV2-ME10
10 3/4 6-10 138 CQV2-ME14
14 4/6.5 9-14 170 CQV2-ME16
18 7/8 13-18 220 CQV2-ME20
23 8/10 17-23 320 CQV2-ME21
25 9/12 20-25 350 CQV2-ME22
32 15 24-32 420 CQV2-ME32
CQV2-ME80 40 18.5 25-40 480 CQV2-ME40 QTY:30PCS
N.W:23KG
G.W:23.5KG
MEAS:42X36X27.7CM
63 28 40-63 720 CQV2-ME63
80 32 56-80 960 CQV2-ME80

Descrição dos Acessórios

CQV-AE: Instantaneous Auxiliary Contact.

CQV-AN/AD/AM: Combination of Signal Contacts for trouble and short-circuit signals.

Modelo de produto Accessory Name Part Code Contact Configuration Mounting Position
CQV-AE Instantaneous Auxiliary Contact AE1 1NO or 1NC Front
CQV-AE Instantaneous Auxiliary Contact AE11 1NO or 1NC Front
CQV-AE Instantaneous Auxiliary Contact AE20 2NO Front
CQV-AN (-AD-AM) Trouble Signal Contact AD1001 1NC (Fault) Left
CQV-AN (-AD-AM) Trouble Signal Contact AD1010 1NO (Fault) Left
CQV-AN (-AD-AM) Instantaneous Auxiliary Contact AM11 1NO + 1NC Left

CQV-AU/AX/AS: Under-voltage Disjoining Accessory.

Modelo de produto Release Type Part Code Tensão Operating Range
CQV2-AU (-AX-AS) Undervoltage Release AU225 220-240V AC Operate: 0.85-1.1Ue;
Trip: 0.35-0.7Ue
CQV2-AU (-AX-AS) Undervoltage Release AU385 380-415V AC Operate: 0.85-1.1Ue;
Trip: 0.35-0.7Ue
CQV2-AU (-AX-AS) Shunt Release AS115 220-240V AC Operate: 0.85-1.1Ue;
Trip: 0.2-0.75Ue
CQV2-AU (-AX-AS) Shunt Release AS225 220-240V AC Operate: 0.85-1.1Ue;
Trip: 0.2-0.75Ue
CQV2-AU (-AX-AS) Shunt Release AS385 220-240V AC Operate: 0.85-1.1Ue;
Trip: 0.2-0.75Ue

CQV2-MC02: Circuit Shield

Modelo de produto Aplicação Protection Type Protection Rating Packing Dimensions (cm)
CQV2-MC02 For CQV2 breakers with/without accessories (max 1/side) Surface-mount. double-insulated, sealed cover IP55 51×31.5×48.5

Porquê escolher a CHAC

Com mais de 30 anos de experiência em fabrico, mais de 1100 funcionários, mais de 100 milhões de postes
Com uma capacidade anual e um processo de produção automatizado 90%, a CHAC garante uma capacidade de produção estável e rigorosos
Controlo de qualidade para clientes OEM/ODM globais. O nosso sistema de fabrico interno suporta a longo prazo
cooperação para marcas elétricas, importadores e distribuidores.


30+

ANOS DE EXPERIÊNCIA

Especializado em fabrico de baixa tensão elétrica


1100+

FUNCIONÁRIOS

Equipa profissional garante qualidade e entrega estáveis


100M+

CAPACIDADE ANUAL DE POSTOS

Capacidade de produção em larga escala para satisfazer a procura global


90%

PRODUÇÃO AUTOMATIZADA

Automação avançada para alta eficiência e consistência

Linha de Montagem Automatizada

Linha de Montagem Automatizada

Laboratório de Ensaios

Laboratório de Ensaios

Injeção e Estampagem

Injeção e Estampagem

Inspeção de Qualidade

Inspeção de Qualidade

Certificação IEC
Certificação CE
Certificação CB
Certificação RoHS
Certificação ISO 14001

Um rigoroso sistema de controlo de qualidade garante que cada produto cumpre as normas globais.

O que podemos personalizar?

A CHAC suporta a personalização da tensão da bobina e da configuração dos contactos auxiliares,
parâmetros elétricos, branding do produto, design de embalagem e desenvolvimento de engenharia de acordo com os equipamentos dos clientes e os requisitos do mercado.

Tensão da bobina

Tensão da bobina

Opções de tensão de bobina AC e DC adaptadas aos requisitos da aplicação.

Personalização da tensão da bobina para opções de tensão de bobina AC e DC
Contactos Auxiliares

Contactos Auxiliares

Combinações flexíveis de contactos auxiliares para diferentes funções de controlo.

Personalização de contactos auxiliares para diferentes funções de controlo
Parâmetros Elétricos

Parâmetros Elétricos

As classificações atuais, os intervalos de proteção e os parâmetros funcionais podem ser personalizados.

Personalização de parâmetros elétricos para classificações de corrente e intervalos de proteção
Branding de Produto

Branding de Produto

Logótipos de marca própria, placas de identificação e suporte para identificação de produtos.

Personalização da marca do produto, incluindo logótipos de marca própria e placas de identificação
Design de Embalagem

Design de Embalagem

Caixas personalizadas, etiquetas, manuais e soluções de embalagem.

Personalização de design de embalagens, incluindo caixas, rótulos, manuais e soluções de embalagem
Desenvolvimento de engenharia

Desenvolvimento de engenharia

Suporte desde a otimização de desenhos ao desenvolvimento de produtos e à compatibilidade de aplicações.

Apoio ao desenvolvimento de engenharia, desde a otimização de desenhos até ao desenvolvimento de produtos

Transferir

PDF

Protetor de Motor Série CQV2

Visão geral completa de componentes elétricos de baixa tensão e referência para seleção de produtos.

Transferir PDF

SUP

Precisa de Documentos Técnicos?

Contacte-nos para folhas de dados, certificados, desenhos, orientação de seleção ou suporte a projetos OEM/ODM.

Contacte-nos

CQV2 Product FAQ

What protection does the CQV2 provide?

The product record describes overload, phase-failure and short-circuit protection for compatible AC motor circuits. Confirm the exact setting range and motor data.

How is the current setting selected?

Set the protector from the motor nameplate and measured operating conditions, then verify starting current, ambient temperature and conductor coordination.

Can it be used as an isolator?

The current record identifies an isolation function, but the installation must still meet the required isolation, enclosure and local-code conditions.

Which motors are suitable?

The published application is three-phase squirrel-cage asynchronous motors. Confirm motor power, voltage, duty and starting method.

What accessories can be added?

Auxiliary, signal or under-voltage accessories depend on the CQV2 variant. Check the exact accessory code and wiring diagram.

How should nuisance trips be investigated?

Record motor current, phase balance, start time, ambient temperature and terminal condition before changing the setting.

Confirm the Right CQV2 Configuration

Send the exact model, operating conditions, quantity, destination market and required documents. CHAC will review the request against the published product data.

Pedir um orçamento