Disjuntor em Caixa Moldada da Série CQM7DC

O CQM7DC MCCB provides overload and short-circuit protection for DC systems within its published 63–1600A range. Specification should follow the system voltage, load, conductor coordination, prospective fault current and applicable rules—not the ampere value alone.

Polacos:
2P / 3P / 4P
Corrente Nominal:
63–1600A
Tensão Nominal:
1500V DC
Trip / Protection:
overload and short-circuit protection for DC systems
Dados de Última Hora:
Icu/Ics values vary by voltage and frame; verify the ordered table
Normal
UL 489 requirements listed on the page

Visão Geral do Produto

CQM7DC is a dc MCCB for 1500V DC distribution and protection applications. Its published range covers 63–1600A with 2P / 3P / 4P options. Selection depends on the complete power-system design, including fault level, coordination, conductor ampacity, enclosure conditions and local rules.

The saved model record lists UL 489 requirements listed on the page as the applicable standard reference. No certification claim is added beyond the model record.

Principais Características

  • Published current range: 63–1600A.
  • Pole options: 2P / 3P / 4P.
  • Protection function: overload and short-circuit protection for DC systems.
  • Trip or setting information: 5In or 10In instantaneous setting.
  • Short-circuit data: Icu/Ics values vary by voltage and frame; verify the ordered table.
  • Electrical reference: 1500V DC.
  • Accessories, terminals and installation details must be confirmed for the ordered frame and configuration.

Aplicações Típicas

Typical applications include solar PV, EV charging and energy-storage distribution where the complete DC fault study supports the rating. These are evaluation contexts rather than universal approvals. Confirm the exact frame, voltage, breaking duty, trip unit, accessories and installation method before specification.

Guia de Candidaturas e Seleção

Use the verified CQM7DC values below to create a shortlist, then validate the complete circuit. An MCCB rating does not replace conductor calculations, fault-current analysis, coordination review or local installation requirements.

Ponto de seleção CQM7DC reference O que o projeto deve confirmar
Corrente nominal 63–1600A Design current, conductor ampacity, installation method, temperature and grouping
Tensão 1500V DC Sistema de alimentação e classificação de equipamento
Polacos 2P / 3P / 4P Live conductors and neutral treatment
Trip / protection 5In or 10In instantaneous setting Load profile, fault response and coordination
Capacidade de corte Icu/Ics values vary by voltage and frame; verify the ordered table Prospective short-circuit current at the installation point

AC MCCB vs DC MCCB

DC interruption is not interchangeable with AC interruption. Use the CQM7DC voltage, pole, arc-distance and fault-duty data for the intended PV, EV or storage circuit.

DC Interruption
Review DC MCCB Range →

MCCB vs MCB

An MCCB is normally evaluated for higher current, fault duty or accessory flexibility; an MCB may be more suitable for compact final circuits.

Current & Fault Duty
Compare MCCB and MCB →

Icu vs Ics

The saved data for CQM7DC lists Icu/Ics values vary by voltage and frame; verify the ordered table. Match the declared duty to the prospective short-circuit current and continuity objective.

Short-Circuit Study
Review Technical Support →

Pole and Neutral Arrangement

Published pole options are 2P / 3P / 4P. Confirm which conductors must be switched, protected and isolated together.

System Arrangement
View MCCB Range →

Guia de Encomenda

  1. State the exact model: CQM7DC.
  2. Provide frame and rated current within the published range: 63–1600A.
  3. Confirm poles: 2P / 3P / 4P.
  4. Specify the trip unit or protection function: 5In or 10In instantaneous setting.
  5. Provide system voltage, frequency, application, expected fault level, destination market and quantity.
  6. List required accessories, terminals, documents and any approved OEM/ODM marking or packaging requirements.

Verificações de Instalação e Coordenação

  • Use the exact model drawing and instructions; do not infer terminal positions, supply direction or accessory compatibility from another MCCB.
  • Verify conductor material and cross-section against the circuit calculation, terminal data, temperature and grouping.
  • Confirm Icu/Ics or DC fault duty, upstream/downstream coordination, enclosure conditions, altitude and clearances.
  • Installation, isolation, testing and maintenance must be performed by qualified personnel under applicable rules.

Designação do tipo

Accessory List

Note: Code 50:For models 125 and 160, a custom left-side undervoltage release is required. For model 250, a custom left-side shunt release is required.Optional voltage ranges for shunt/undervoltage releases:DC24V, DC110V, DC220V, AC230V, AC400V.Standard production voltage: AC230V.

Especificações Técnicas

Parâmetro CQM7DC-320 CQM7DC-630 CQM7DC-1600
Rated Current (A) 63, 80, 100, 125, 140, 160, 180, 200, 225, 250, 315, 320 225, 250, 320, 350, 400, 500, 630 800, 1000, 1250, 1500, 1600
Número de Polos 2P 2P 3P,4P
Rated Operational Voltage Ue DC (V) 1500 1500 1500
Rated Insulation Voltage Ui (V) 1800 1800 1800
Rated Impulse Withstand Voltage Uimp (kV) 12 12 12
Power Frequency Withstand Voltage (1 min) (kV) 3.5 3.5 3.5
Rated Ultimate Short-Circuit Breaking Capacity Icu DC1200V DC1500V DC750V DC1000V DC750V DC1000V
DC1200V DC1500V
Rated Service Short-Circuit Breaking Capacity Ics (kA) 35kA 20kA 85kA 50kA 50kA 30kA
15kA 10kA
Mechanical Life (operations) 4000 4000 4000
Electrical Life (operations) 10000 10000 500
Arc Chute Distance (mm) 50 / 0 50 / 0 50 / 0
Dimensions W×L×H (mm) 90×215×136 110×275×152 3P: 210×340×244
4P: 280×340×244
Instantaneous Trip Setting 5In or 10In 5In or 10In 5In or 10In
Reference Ambient Temperature (℃) 50 50 50

Porquê escolher a CHAC

Com mais de 30 anos de experiência em fabrico, mais de 1100 funcionários, mais de 100 milhões de postes
Com uma capacidade anual e um processo de produção automatizado 90%, a CHAC garante uma capacidade de produção estável e rigorosos
Controlo de qualidade para clientes OEM/ODM globais. O nosso sistema de fabrico interno suporta a longo prazo
cooperação para marcas elétricas, importadores e distribuidores.


30+

ANOS DE EXPERIÊNCIA

Especializado em fabrico de baixa tensão elétrica


1100+

FUNCIONÁRIOS

Equipa profissional garante qualidade e entrega estáveis


100M+

CAPACIDADE ANUAL DE POSTOS

Capacidade de produção em larga escala para satisfazer a procura global


90%

PRODUÇÃO AUTOMATIZADA

Automação avançada para alta eficiência e consistência

Linha de Montagem Automatizada

Linha de Montagem Automatizada

Laboratório de Ensaios

Laboratório de Ensaios

Injeção e Estampagem

Injeção e Estampagem

Inspeção de Qualidade

Inspeção de Qualidade

Certificação IEC
Certificação CE
Certificação CB
Certificação RoHS
Certificação ISO 14001

Um rigoroso sistema de controlo de qualidade garante que cada produto cumpre as normas globais.

O que podemos personalizar?

For CQM7DC projects, CHAC can review private-label marking, packaging, approved appearance options, published 63–1600A electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, minimum order quantity and project feasibility.

Design de Caixa

Recinto
Design

Tamanhos de caixas personalizadas, estruturas e detalhes de instalação.

Design de Caixa
Configuração Interna

Interno
Configuração

Layout interno flexível e opções de arranjo de componentes.

Configuração Interna
Branding e Logótipo

Branding &
Logótipo

Logótipos de marca própria, placas de identificação e identificação da marca.

Branding e Logótipo
Design de Embalagem

Embalagem
Design

Caixas personalizadas, etiquetas, manuais e soluções de embalagem.

Design de Embalagem
Configuração Elétrica

Elétrico
Configuração

Instalação elétrica à medida com base nos requisitos da aplicação.

Configuração Elétrica
Suporte de Certificação

Certificação
Apoio

Apoio a normas e requisitos de conformidade do mercado-alvo.

Suporte de Certificação

Transferir

PDF

Outros Produtos

Visão geral completa de componentes elétricos de baixa tensão e referência para seleção de produtos.

Transferir PDF

SUP

Precisa de Documentos Técnicos?

Contacte-nos para folhas de dados, certificados, desenhos, orientação de seleção ou suporte a projetos OEM/ODM.

Contacte-nos

CQM7DC Product FAQ

What is the CQM7DC MCCB used for?

The CQM7DC is specified for overload and short-circuit protection for DC systems in 1500V DC systems within the published 63–1600A range. Suitability depends on the fault study, conductor coordination, enclosure and local rules.

What is the CQM7DC 1500V DC rating?

The page lists 1500V DC as the rated operational voltage. DC interruption is not interchangeable with AC interruption, so the pole arrangement, arc path, fault current and installation instructions must be checked for the actual PV, EV or storage circuit.

How do I choose the CQM7DC rated current and poles?

Start with the design current and conductor calculation, then choose a published current within 63–1600A and poles from 2P / 3P / 4P. Neutral treatment, fault level, ambient conditions and coordination also need review.

What breaking capacity should I check on the CQM7DC?

Use the declared Icu/Ics values vary by voltage and frame; verify the ordered table for the exact frame, voltage and configuration. The prospective short-circuit current at the installation point must be within the applicable duty; a larger ampere value alone is not a selection rule.

Can the CQM7DC replace an MCB or an earth-leakage device?

An MCCB is not automatically a like-for-like replacement. The CQM7DC provides overload and short-circuit protection for DC systems; residual-current protection, DC interruption, adjustable settings and other functions must be confirmed separately from the project requirement.

How should the CQM7DC be installed and tested?

Use only the exact model drawing, terminal identification and accessory instructions. A qualified person should verify isolation, conductor size, torque, clearances, settings, fault duty and functional tests before energising the circuit.

Confirm the Right CQM7DC Configuration

Send the frame, rated current, poles, protection function, system voltage, expected fault level, destination market and quantity. CHAC will review the request against the published model range.

Pedir um orçamento