PXD6-125 DSL Isolator
Phần PXD6-125 is specified for safe electrical isolation and infrequent switching. Select it using the published voltage, current, pole and protection data, then confirm conductor coordination, fault conditions, enclosure requirements and local installation rules.
Product Overview
PXD6-125 is a 125A isolator switch for AC 230/400V applications. It is intended for control and terminal distribution assemblies requiring a visible OFF position; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.
safe electrical isolation and infrequent switching is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.
Key Features
Typical Applications
control and terminal distribution assemblies requiring a visible OFF position. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.
Applications and Selection Guide
Use the verified PXD6-125 records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.
| Selection point | PXD6-125 reference | What the project must confirm |
|---|---|---|
| Rated current | Use the exact model table | Design current, conductor capacity, ambient and grouping |
| Voltage and frequency | AC 230/400V | Supply system and equipment rating |
| Người Ba Lan | 1P / 2P / 3P / 4P | Conductors to be switched, protected or isolated |
| Protection / control | safe electrical isolation and infrequent switching | Required function and adjacent-device coordination |
| Fault / residual data | Isolation function; not an overcurrent substitute | Prospective short-circuit or leakage conditions |
Isolation vs Overcurrent Protection
An isolating switch provides a means of disconnection but is not automatically an overcurrent protective device. Coordinate it with the upstream breaker.
Safe Isolation
Review MCB Options →
Model-Specific Ratings
Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.
Verified Data
View Technical Support →
Installation and Coordination
Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.
Engineering Check
Discuss a Configuration →
Ordering Information
State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.
Project Inputs
Send Project Details →
Ordering Guide
- State the exact model: PXD6-125.
- Provide rated current and voltage from the published technical table.
- Confirm poles and the required protection, isolation or control function.
- Provide application, expected fault/leakage conditions, destination market and quantity.
- List accessory, terminal, documentation and approved marking or packaging requirements.
Installation and Coordination Checks
- Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
- Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
- Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
- Installation, testing and maintenance must be completed by qualified personnel under applicable rules.
Type designation

Dimensions(mm)

Technical Specifications
| Parameter | |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Operational Voltage Ue (V) | 230V/400(1P), 400V(2P, 3P, 4P) |
| Rated Operational Current Ie (A) | 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A |
| Number of Poles | 1P, 2P, 3P, 4P |
| Rated Short-Time Withstand Current Icw | 12Ie (t=1s) |
| Rated Short-Circuit Making Capacity Icm | 20Ie (t=0.05s) |
| Rated Impulse Withstand Voltage Uimp | (1.2 / 50μs, 2000m) 4000V |
| Rated Making and Breaking Capacity | 3Ie, 1.05Ue, cosΦ=0.65 |
| Mechanical Life | ≥8500 |
| Electrical Life | ≥1500 |
| Standard | IEC60947-3, GB/T 14048.3 |
| Chứng nhận | CCC |
Conductor requirements and cross section
| Copper cross-section(mm2) | Rated current In(A) |
| 6 | 32A |
| 10 | 40A |
| 10 | 50A |
| 16 | 63A |
| 25 | 80A |
| 35 | 100A |
| 50 | 125A |
Tại sao nên chọn CHAC
With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.
30+
NĂM KINH NGHIỆM
Chuyên sản xuất thiết bị điện hạ thế
1100+
CÔNG NHÂN
Đội ngũ chuyên nghiệp đảm bảo chất lượng và giao hàng ổn định
100 triệu người
Sức chứa hàng năm của các cột
Năng lực sản xuất quy mô lớn để đáp ứng nhu cầu toàn cầu
90%
SẢN XUẤT TỰ ĐỘNG
Tự động hóa nâng cao cho hiệu quả cao và tính nhất quán

Dây chuyền lắp ráp tự động

Phòng thí nghiệm kiểm nghiệm

Xay và dập

Kiểm tra chất lượng





Strict quality control system ensures every product meets global standards.
Chúng tôi có thể tùy chỉnh những gì?
For PXD6-125 projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.
Logo & Thương hiệu
Dịch vụ in logo theo yêu cầu, khắc laser và giải pháp bảng tên.

Gói bao bì
Tùy chỉnh
Bao bì màu sắc được tùy chỉnh, thùng carton, nhãn mác và hướng dẫn sử dụng.

Điện
Tùy chỉnh
Current, voltage, breaking capacity, trip curve and other
special functions.

Sản phẩm
Vẻ ngoài
Tùy chỉnh màu sắc của đồ nội thất, màu sắc của tay cầm và kiểu dáng.

Chứng nhận
Hỗ trợ
Products comply with international standards and market
requirements.

Kỹ thuật
Phát triển
Việc đánh giá thiết kế, thử nghiệm nguyên mẫu và sản xuất hàng loạt.

Tải xuống
Bộ ngắt mạch nhỏ dòng PXB6
Complete product overview for low-voltage electrical components and product selection reference.
Need Technical Documents?
Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.
PXD6-125 Product FAQ
What is the PXD6-125 used for?
The PXD6-125 is specified for safe electrical isolation and infrequent switching in AC 230/400V applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.
Does the PXD6-125 provide overload protection?
No overcurrent claim is added for this isolating switch. It provides the documented isolation and switching function; coordinate it with the appropriate upstream protective device.
How do I choose the PXD6-125 rating and poles?
Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 1P / 2P / 3P / 4P; confirm neutral, polarity, conductors and isolation requirements.
What safety limitation applies to the PXD6-125?
Do not treat the PXD6-125 as a universal substitute for another device. Confirm Isolation function; not an overcurrent substitute, the system voltage, fault or leakage conditions and any separate upstream protection before selection.
Can the PXD6-125 be used in another circuit type?
Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.
How should the PXD6-125 be installed and tested?
Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.
Confirm the Right PXD6-125 Configuration
Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.