CQM6RT Thermal-Magnetic Adjustable MCCB OEM Manufacturer
Product Features
■ Field-Adjustable Settings: Allows for precise on-site customization of both overload (Ir) and short-circuit (Im) protection settings foroptimized coordination.
■ Dual Protection Curves: Available with trip units optimized for either “Power Distribution” or “Motor Protection” applications.
■ Proven Robustness: Designed for reliable operation across awide temperature range (-35℃ to +70℃) and at high altitudes up to 2000m.
■ Accessory Compatibility: Supports a full range of accessories including shunt releases and undervoltage trips, for extended control capabilities.
Compliance
■ Meets international and regional standards including
IEC/EN 60947-1( General Rules) GB/T 14048.1
IEC/EN 60947-2(Circuit-Breakers) GB/T 14048.2
IEC/EN 60947-3(Switchgear) GB/T 14048.3
IEC/EN 60947-4( Contactors & Motor-Starters) GB/T 14048.4
Accessory List


1.MH can provide thre new products right auxiary svitch,left stunt and left undervoltape for custorrersto chose.
2.In 220,320,240,340,270,370 specincafons,the auxilary swichcanbe used for Mopairs of swches,which shoukdbe specfied when ordering.
Selection Guide

| Product code ① | Shell frame grade ② | Shell frame grade ③ | Breaking capacity ④ | ||||
| CQM6 | RT | 160 | C | ||||
| Molded case circuit breaker | RT stands for thermomagnetic ally adjustable T、 A stands for single adjustable (i.e., thermally adjustable/magnetically fixed). |
C | S | M | H | ||
| 160 | 160 | 25/18 | 35/25 | 50/35 | / | ||
| 250 | 250 | 25/18 | 35/25 | 50/35 | / | ||
| 630 | 630 | / | 35/25 | 50/35 | 75/50 | ||
| 800 | 800 | / | 35/25 | 50/35 | 75/50 | ||
| Operating method ⑤ | The number of poles ⑥ | Decoupler method and internal accessories ⑦ | Rated current A | |
| P | 4 | 300 | 125A | |
| P: Motorized operation Z: Turn the handle W: Direct operation Delectric operation DC1DC 2,DC3 |
2: 2-pole 3: 3-pole 4: 4-pole |
The first digit indicates the type of detent 2: Instantaneous detent only 3: Duplicate detent Note: The last two digits are the accessory designator (see accessory table). |
160 | 32,40,50,63,80,100,125,140,160 |
| 250 | 100,125,140,160,180,200,225,250 | |||
| 630 | 250,315,350,400,500,630 | |||
| 800 | 500,630,700,800 | |||
| Application⑧ | Optional code for Level 4 products⑨ | Special code⑩ |
| 2 | A | I |
| 1:For power distribution | A:N-pole unprotected,not combinable A | I:Overload alarm non |
| 2:For motor protection | B:N-pole unprotected,combinable | trip function |
| Accessory Voltage⑪ | Motorized operating voltage⑫ | Installation⑬ | Whether to install a terminal block⑭ | |||
| Q1 | D1 | Q | 2 | |||
| Undervoltage detent UVT | Shunt release Shunt |
Auxiliary alarm Auxiliary |
DC1 | DC3 D5: AC230V | Q: Front of plate H: Rear of plate C: Inserted |
1: No installation 2: Installation |
| Q1: AC220V | F1: AC220V | J1: AC125V | D1: AC220V | D6: AC110V | ||
| Q2: AC240V | F2: AC380V | J2: AC250V | D2: AC230V | D7: DC220V | ||
| Q3: AC380V | F3: DC110V | J3: DC125V | D3: AC380V | D8: DC110V | ||
| Q4: AC415V | F4: DC24V | J4: DC24V | D4: AC400V | D9: AC110~240V | ||
| D10: DC100~220V | ||||||
Main Technical Parameters
| Model number | CQM6T/A.RT-160 | CQM6T/A.RT-250 | ||||||
| Rated current of frame level Inm(A) | 160 | 250 | ||||||
| Number of poles | 3, 4 | 3, 4 | ||||||
| Rated current In(A),at 40℃,50℃,55℃ | 63,80,100,125,160 | 125,140,160,180,200,225,250 | ||||||
| Rated operating voltage Ue(V),AC 50/60Hz | 400/415 | 400/415 | ||||||
| Rated insulation voltage Ui (V) | 800 | 800 | ||||||
| Rated impulse withstand voltage Uimp(KV) | 8 | 8 | ||||||
| Breaking capacity designation | C | S | M | C | S | M | ||
| Short-circuit breaking capacity Icu/Ics(kA) | AC400/415V | 25/18 | 35/25 | 50/35 | 25/18 | 35/25 | 50/35 | |
| Selectivity category | A | A | A | A | A | A | ||
| Number of operating cycles(cycle) | ON | 6000 | 6000 | |||||
| OFF | 10000 | 10000 | ||||||
| Trip mechanisms and protection types |
Magnetic trip | Power distribution protection | ● | ● | ● | ● | ● | ● |
| Motor protection | ● | ● | ● | ● | ● | ● | ||
| Thermal-magnetic trip | Power distribution protection | ● | ● | ● | ● | ● | ● | |
| Motor protection | ● | ● | ● | ● | ● | ● | ||
| Accessory | Auxiliary contacts | ● | ● | ● | ● | ● | ● | |
| Alarm contacts | ● | ● | ● | ● | ● | ● | ||
| Shunt disconnect | ● | ● | ● | ● | ● | ● | ||
| Undervoltage detent | ● | ● | ● | ● | ● | ● | ||
| Manual operating mechanism | ● | ● | ● | ● | ● | ● | ||
| Motorized operating mechanism | ● | ● | ● | ● | ● | ● | ||
| Backplane wiring | ● | ● | ● | ● | ● | ● | ||
| Inserted | ● | ● | ● | ● | ● | ● | ||
| Coupling plate | ● | ● | ● | ● | ● | ● | ||
| Partition between phases | ● | ● | ● | ● | ● | ● | ||
| Derivative products | Dedicated for prepayment electric meters | ● | ● | ● | ● | ● | ● | |
| Overload alarm without trip | ● | ● | ● | ● | ● | ● | ||
| Overall dimensions (mm) (a-b-c-ca) |
![]() |
3 P | 90-155-70-94 | 90-155-84-109 | 105-165-70-96 | 105-165-93-120 | ||
| 4 P | 120-155-70-94 | 120-155-84-109 | 140-165-70-96 | 140-165-93-120 | ||||
Note: ● for optional accessories;“-”for no optional accessories.
| Model number | CQM6T/A.RT-630 | CQM6T/A.RT-800 | ||||||
| Rated current of frame level Inm(A) | 630 | 800 | ||||||
| Number of poles | 3, 4 | 3, 4 | ||||||
| Rated current In(A),at 40℃,50℃,55℃ | 250,315,350,400,500,630 | 500,630,700,800 | ||||||
| Rated operating voltage Ue(V),AC 50/60Hz | 400/415 | 400/415 | ||||||
| Rated insulation voltage Ui (V) | 800 | 800 | ||||||
| Rated impulse withstand voltage Uimp(KV) | 8 | 8 | ||||||
| Breaking capacity designation | S | M | H | S | M | H | ||
| Short-circuit breaking capacity Icu/Ics(kA) | AC400/415V | 35/25 | 50/35 | 75/50 | 35/25 | 50/35 | 75/50 | |
| Selectivity category | A | A | A | A | A | A | ||
| Number of operating cycles(cycle) | ON | 3000 | 3000 | |||||
| OFF | 8000 | 8000 | ||||||
| Trip mechanisms and protection types |
Magnetic trip | Power distribution protection | ● | ● | ● | ● | ● | ● |
| Motor protection | ● | ● | ● | ● | ● | ● | ||
| Thermal-magnetic trip | Power distribution protection | ● | ● | ● | ● | ● | ● | |
| Motor protection | ● | ● | ● | ● | ● | ● | ||
| Accessory | Auxiliary contacts | ● | ● | ● | ● | ● | ● | |
| Alarm contacts | ● | ● | ● | ● | ● | ● | ||
| Shunt disconnect | ● | ● | ● | ● | ● | ● | ||
| Undervoltage detent | ● | ● | ● | ● | ● | ● | ||
| Manual operating mechanism | ● | ● | ● | ● | ● | ● | ||
| Motorized operating mechanism | ● | ● | ● | ● | ● | ● | ||
| Backplane wiring | ● | ● | ● | ● | ● | ● | ||
| Inserted | ● | ● | ● | ● | ● | ● | ||
| Coupling plate | ● | ● | ● | ● | ● | ● | ||
| Partition between phases | ● | ● | ● | ● | ● | ● | ||
| Derivative products | Dedicated for prepayment electric meters | ● | ● | ● | ● | ● | ● | |
| Overload alarm without trip | ● | ● | ● | ● | ● | ● | ||
| Overall dimensions (mm) (a-b-c-ca) |
![]() |
3 P | 210-275-105-155 | 210-275-105-155 | ||||
| 4 P | 280-275-105-155 | 280-275-105-155 | ||||||
Note: ● for optional accessories;“-”for no optional accessories.
Operating Characteristics
1.The inverse time operating characteristics of power distribution circuit breakers when all poles are energized simultaneously at anambient airtemperature of +40℃(with no humidity compensation)are shown in the following table:
| Test current designation | Setting current multiple | Conventional time | Initial state |
| In≤63 In > 63 | |||
| Conventional non-tripping current | 1.05 | ≥1h ≥2h | Cool state |
| Conventional tripping current | 1.30 | <1h<2h | Hot state |
2.The inverse time action characteristics of circuit breakers for motor protection without humidity compensation when all poles areenergizedsimultaneously at an ambient air temperature of +40℃ are shown in the following table.
| Test current designation | Setting current multiple | Conventional time | Initial state |
| In≤800 | |||
| Conventional non-tripping current | 1.0 | ≥2h | Cool state |
| Conventional tripping current | 1.20 | <2h | Hot state |
3.Action characteristics under short-circuit condition:The short-circuitcurentsetting value of the instantaneous tripper of the circuitbreaker for power distribution is 10ln.
The short-circuit current setting value of the instaneous tripper of the circuit breaker for motorprotection is 12ln.
The accuracy of the short-circuit curent setting value of the instantarheous tripper is 20%of the short-circuit currentsetting value.
CQMGT/A.RT-160 Operating Characteristic Curve

CQMGT/A.RT-250 Operating Characteristic Curve

CQMGT/A.RT-630 Operating Characteristic Curve

CQMGT/A.RT-800 Operating Characteristic Curve

Outline and Installation Dimensions(mm)

| Molded case circuit breaker | Overall dimension | Installation dimensions | Bolt | |||||||||||||||||||||
| A | A1 | A2 | A3 | B | B1 | B2 | B3 | B5 | B6 | H | H1 | H2 | H3 | H4 | H5 | H6 | A4 | B4 | ||||||
| 3P | 4P | 3P | 4P | 3P | 4P | 3P | 4P | |||||||||||||||||
| CQM6T/A.RT-160CS | 90 | 120 | 60 | 90 | – | – | – | – | 155 | 134 | 103 | 50 | 50 | – | 94 | 72 | 4 | 70 | 61 | 41 | 24 | 30 | 132 | M8 |
| CQM6T/A.RT-160M | 90 | 120 | 60 | 90 | – | – | – | – | 155 | 134 | 103 | 50 | 50 | – | 109 | 83 | 4 | 83 | 76 | 24.5 | 24.5 | 30 | 132 | M8 |
| CQM6T/A.RT-250CS | 105 | 140 | 70 | 105 | – | – | – | – | 165 | 144 | 103 | 50 | 100 | – | 96 | 72 | 4 | 70 | 61 | 46 | 24 | 35 | 126 | M8 |
| CQM6T/A.RT-250M | 105 | 140 | 70 | 105 | – | – | – | – | 165 | 144 | 102 | 50 | 110 | – | 120 | 95 | 4 | 91 | 84 | 22.5 | 24 | 35 | 126 | M8 |
| CQM6T/A.RT-630SMH | 140 | 185 | 88 | 132 | 140 | 196 | 112 | 168 | 257 | 230 | 179 | 90 | 110 | 42 | 155 | 107 | 5 | 105 | 97 | 64 | 35 | 44 | 194 | M10 |
| CQM6T/A.RT-800SMH | 210 | 280 | 140 | 210 | 180 | 250 | 140 | 210 | 275 | 243 | 192 | 90 | 110 | 87 | 155 | 107 | 5 | 104 | 97 | 65 | 24 | 70 | 242.5 | M12 |
Why Choose CHAC
With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.
30+
YEARS EXPERIENCE
Specialized in low-voltage electrical manufacturing
1100+
EMPLOYEES
Professional team ensures stable quality and delivery
100M+
POLES ANNUAL CAPACITY
Large-scale production capacity to meet global demand
90%
AUTOMATED PRODUCTION
Advanced automation for high efficiency and consistency

Automated Assembly Line

Testing Laboratory

Injection & Stamping

Quality Inspection





Strict quality control system ensures every product meets global standards.
What Can We Customize?
Flexible customization services are available for enclosure dimensions, component configuration,
branding and project requirements.
Enclosure
Design
Customized enclosure sizes, structures and installation details.

Internal
Configuration
Flexible internal layout and component arrangement options.

Branding &
Logo
Private label logos, nameplates and brand identification.

Packaging
Design
Custom cartons, labels, manuals and packaging solutions.

Electrical
Configuration
Tailored electrical setup based on application requirements.

Certification
Support
Support for target-market standards and compliance requirements.

Download
CQM6 Series Moulded Case Circuit Breaker
Complete product overview for low-voltage electrical components and product selection reference.
Need Technical Documents?
Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.
Frequently Asked Questions
Q1. Do you support product customization based on our design requirements?
A1:Absolutely. We specialize in OEM and ODM cooperation in the low-voltage electrical field and have provided customized services for many internationally renowned companies. We offer full-process support, including R&D design, parameter adjustments, and special material selection, ensuring the product fully meets your requirements.
Q2: What is your production capacity and Minimum Order Quantity (MOQ)?
A2: We operate a highly automated production base with an annual output of over 100 million poles for miniature circuit breakers. Our MOQ policy is flexible. We can provide competitive trial orders for small batches and dedicated production capacity guarantee plans.
Q3: What assurances are there for product quality and certifications?
A3: Our main products are certified with CCC, CE, CB, and more, and are sold in over 30 countries and regions worldwide. The company has established a dedicated Quality Operations Center that works with the business and production departments to implement full-process quality control, ensuring products meet international standards.
Q4: Do you have the capability for product R&D and turning concepts into reality?
A4: We have a complete R&D team and digital workshops, backed by extensive customization experience serving numerous international clients. From concept proposal and sample development to mass production, we provide end-to-end technical support to help bring your ideas to life.