مفتاح الفصل الكهربائي DC Series CQD5NEZ
تم تصميم مفتاح فصل التيار المستمر CHAC CQD5NEZ لعزل الدائرة عند جهد يصل إلى 1500V تيار مستمر. يغطي حجمان للإطار تيارات مقدرة تتراوح من 80A إلى 630A، مع تشغيل أمامي أو جانبي بما يناسب تخطيط المعدات.
مواصفات المنتج
الجنة العليا للأشخاص ذوي الإعاقة CQD5NEZ 1500V DC isolator switch offers front or side operation for equipment and cabinet integration. The two-pole range uses 315A and 630A frames, covering rated currents from 80A to 630A across the listed variants.
For importers, distributors and equipment manufacturers, CHAC can review the requested configuration against the circuit requirements and destination-market documents. Agree the exact model, drawings and marking requirements before sample approval or a repeat order.
Key Selection Points
الاستخدامات النموذجية
Evaluate CQD5NEZ for DC equipment requiring a defined isolation point and a suitable operating arrangement. Confirm the utilization duty and protection coordination for the application; the product name alone does not establish every load-breaking condition.
طلبات واقتراحات واختيار المرشحين
| مكون الاختيار | CQD5NEZ configuration | ما يجب التحقق منه |
|---|---|---|
| Frame and current | 315 frame: 80–315A; 630 frame: 315–630A in listed steps | Select the exact frame/current combination. |
| جهد التشغيل | 1500V DC; 2P | Use the approved circuit connection and insulation arrangement. |
| Operating arrangement | Front or side; direct handle or external handle with shaft | Check cabinet depth, door layout and required mounting arrangement. |
| Fault withstand | 315 frame: 8kA/1s; 630 frame: 10kA/1s | Coordinate the stated withstand duration with the protective-device clearing duty. |
Use these checks to compare the protection function, configuration and related CHAC products before specifying CQD5NEZ. Related products are selection alternatives or system components, not automatic replacements.
Select the operating mechanism with the enclosure drawing
Front and side operation change the integration requirements.
Confirm switching duty and site conditions before approval
Supply the load type, operating frequency, fault level, temperature and altitude for a configuration review.
Compare CQW5NEDZ for the required function
The CHAC CQW5NEDZ DC frame isolation switch provides switching and isolation for photovoltaic and energy-storage main circuits. Three frame sizes cover rated currents from 400A to 4000A at 1500V DC; select the frame and utilization category for the application.
Compare CQM5NEZ for the required function
يتم توفير قاطع الدائرة المدمج CHAC CQM5NEZ DC مع وحدات إيقاف التيار الكهربائي الميكانيكي أو الحراري الميكانيكي لدوائر التيار الكهربائي 1500 فولت. اختر نسخة حرارية ميكانيكية عند الحاجة إلى حماية من الحمل الزائد والقصور. تغطي الأطر 350A و630A تيارين محددين بمعدل 63A إلى 630A، مع تحديد قدرة كسر التيار الكهربائي حسب الأطر والنسخة M/H.
Need Help Specifying CQD5NEZ?
Send the circuit requirements, selected configuration, destination market and quantity for a model-specific review.
Select the operating mechanism with the enclosure drawing
Front and side operation change the integration requirements. State the handle arrangement, mounting orientation, shaft requirement and auxiliary-contact needs before approving the layout. Verify the required clearances and access on the model drawing.
Confirm switching duty and site conditions before approval
Supply the load type, operating frequency, fault level, temperature and altitude for a configuration review. Confirm the applicable utilization category and site limits in the approved documentation rather than assuming that the maximum voltage and current apply under every condition.
How to Specify a CQD5NEZ Order
Use the configuration details below in the purchase specification. Keep the approved drawing revision and product identification with the order so repeat deliveries can be checked consistently.
| Order detail | Information to include |
|---|---|
| Frame and current | 315 frame: 80–315A; 630 frame: 315–630A in listed steps — Select the exact frame/current combination. |
| جهد التشغيل | 1500V DC; 2P — Use the approved circuit connection and insulation arrangement. |
| Operating arrangement | Front or side; direct handle or external handle with shaft — Check cabinet depth, door layout and required mounting arrangement. |
| Fault withstand | 315 frame: 8kA/1s; 630 frame: 10kA/1s — Coordinate the stated withstand duration with the protective-device clearing duty. |
| Project and documents | Supply the application, installation conditions and destination-market document requirements. |
| Quantity and identification | State the quantity, sample requirement, packaging language and any proposed branding; confirm feasibility before approval. |
Check Installation Fit Before Approval
تعيين النوع

| Code | Description | |
| ① | CQ | Enterprise Code |
| ② | D | Isolator Switch |
| ③ | 5 | Design Code |
| ④ | NEZ | New Energy – DC |
| ⑤ | Frame Size | 315 / 630 |
| ⑥ | Rated Current | See rated current table |
| ⑦ | Operation | Z: Front operation / C: Side operation |
| ⑧ | Handle Type | K: Direct operating handle / P: External handle + extension shaft |
| ⑨ | Mounting | 1: Vertical / 2: Horizontal / 3: Left vertical & right horizontal |
| ⑩ | Auxiliary Contact | 2NO + 2NC |
Operating Conditions
| Operating Altitude | ≤ 2500 m |
| Ambient Temperature | -40°C to +85°C |
| Derating | Required above +70°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | ≤ 50% at +40°C; up to 90% at +20°C |
| Pollution Degree | 3 |
| Protection Degree | IP20 inside cabinet / IP65 outside cabinet |
| التثبيت | Vertical or horizontal |
| Vertical Installation Inclination | ≤ 5° |
المواصفات الفنية
| معامل | CQD5NEZ-315 | CQD5NEZ-630 |
| Frame Size (A) | 315 | 630 |
| Rated Current In (A) | 80, 100, 125, 160, 200, 225, 250, 275, 315 | 315, 325, 400, 500, 630 |
| عدد البولنديين | 2P | 2P |
| Rated Operational Voltage Ue (V) | DC1500 | DC1500 |
| Rated Insulation Voltage Ui (V) | 2000 | 2000 |
| Rated Impulse Withstand Voltage Uimp (kV) | 12 | 12 |
| Rated Short-Circuit Making Capacity Icm (kA) | 10 | 20 |
| Rated Short-Time Withstand Current Icw | 8kA/1s, 20kA/0.15s | 10kA/1s, 20kA/0.15s |
| Mechanical Operations – Front | 10000 | 10000 |
| Mechanical Operations – Side | 3000 | 3000 |
| Electrical Operations | 500 | 400 |
| Operating Mode | Front / Side | Front / Side |
| معايير | IEC 60947-3, GB/T 14048.3 | IEC 60947-3, GB/T 14048.3 |
| شهادة | CCC, CE, TÜV, CB | CCC, CE, TÜV, CB |
Overall and mounting dimensions
CQD5NEZ-315— Front operation

CQD5NEZ-315—Side operation

CQD5NEZ-630— Front operation

CQD5NEZ-630—Side operation

لماذا تختار CHAC
CHAC Electric supplies electrical protection and control products for importers, distributors and equipment brands. For CQD5NEZ, agree the configuration, technical documents, approved sample and identification requirements before production. The company facilities shown below provide company context, not a claim that every model uses the same production or test process.
01
CONFIRM THE SPECIFICATION
Agree the CQD5NEZ configuration, circuit duty and installation requirements.
02
REVIEW THE DOCUMENTS
Confirm model-specific drawings and destination-market requirements.
03
APPROVE THE SAMPLE
Record the accepted configuration and marking requirements.
04
DEFINE ORDER CHECKS
Agree packaging, identification and delivery requirements in the quotation.

خط التجميع الآلي

مختبر اختبار

حقن وختم

فحص الجودة
ما الذي يمكننا تخصيصه؟
Discuss CQD5NEZ product identification, packaging and documentation with CHAC. Each proposed change is subject to technical feasibility, marking rules and approval of the exact order; no altered rating or certification is implied.
الشعار والعلامة التجارية
Submit logo artwork and marking requirements for review against the available print area and mandatory product markings.

Packaging & Manuals
Define carton labels, packaging language, product identification and instruction requirements for the destination market.

Configuration Selection
Specify CQD5NEZ with the required frame and current, operating conditions and protection duty. Confirm the complete order combination.

Assembly Requirements
Provide the mounting and connection requirements for review. Changes to the housing, terminals or operating arrangement require engineering approval.

Market Documentation
Request documents covering the exact CQD5NEZ model and destination market. A standard reference alone is not evidence of certification.

Sample Approval
Agree the sample specification, drawing revision and acceptance criteria before confirming a production order.

Technical Documents and Support
CQD5NEZ Technical Documents
Request the CQD5NEZ datasheet, configuration drawing, installation instructions and available model-specific market documents.Request Datasheet
هل تحتاج إلى وثائق فنية؟
Send the application, electrical requirements, assembly layout and destination market for configuration and document review.اتصل بنا
CQD5NEZ Product FAQ
Can a DC isolator interrupt a short circuit?
Do not treat CQD5NEZ as an automatic circuit breaker. Its making and short-time withstand ratings support coordination checks; the circuit needs an appropriate fault-clearing protective device.
How do I choose front or side operation?
Use the cabinet layout, door arrangement and access requirements. CQD5NEZ supports both, but dimensions and mechanical operating data differ. Confirm the selected mechanism and shaft arrangement against the actual drawing.
Does an IP65 handle make the entire cabinet IP65?
No. The listed inside/outside-cabinet protection conditions do not certify the complete enclosure. Door cutouts, seals, glands and the assembly construction must also satisfy the required protection level.
Can I choose CQD5NEZ by current rating alone?
No. Check operating voltage, poles, utilization category, switching duty, fault coordination and the installation layout together. Confirm the selected combination in the model-specific documentation before approving a substitute.
Can an isolator be switched under load?
Only within its documented switching duty and voltage/current combination. Confirm the applicable utilization category and instructions for CQD5NEZ; do not assume that every device called an isolator has the same load-break capability.
What information is needed for a CQD5NEZ quotation?
Provide the supply voltage, required current, load duty, pole arrangement, installation drawing and fault-coordination requirements. Add control or auxiliary-contact needs where applicable, plus quantity and destination market.
Specify the Right CQD5NEZ Configuration
Send CHAC your required configuration, application, destination market and estimated quantity. We will review the requested specification and provide the relevant technical documents and commercial proposal.