FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection – Electromagnetic Type

The FB2HL-63 RCBO provides overload, short-circuit and residual-current protection within the published 10A–63A range. Its verified product data lists 10kA Icu; 7.5kA Ics, 1P+N / 2P and C. Final selection must match the conductor, load, prospective fault current, installation system and applicable local rules.

Poles:
1P+N / 2P
Rated Current:
10A–63A
Electrical Rating:
240V AC
Frequency:
50/60Hz
Breaking Data:
10kA Icu; 7.5kA Ics
Trip / Residual Type:
C
Standard:
IEC 61009-1
Mounting:
Plug-in mounting

Product Overview

FB2HL-63 is a plug-in residual current circuit breaker with integral overcurrent protection for 240V AC systems. It combines C-curve overload and short-circuit protection with Type AC, 30mA residual-current protection. It should be selected as an RCBO, not as an MCB with implied leakage protection.

The model data references IEC 61009-1. Standards, certification scope and technical documents must be confirmed for the ordered configuration and destination market.

Key Features

  • Published current range: 10A–63A.
  • Pole configuration: 1P+N / 2P.
  • Trip / protection option: C.
  • Short-circuit data: 10kA Icu; 7.5kA Ics.
  • Electrical reference: 240V AC, 50/60Hz.
  • Service-life data: 10,000 mechanical and 4,000 electrical operations.
  • Additional verified data: Type AC; IΔn 30mA; IΔm 2,000A; 500V Ui; 4kV Uimp; IP20; 1–25mm² conductors.

Typical Applications

Typical projects include compatible single-phase distribution boards where combined overcurrent and residual-current protection is specified. Confirm the expected residual-current waveform, required sensitivity, conductor size, prospective fault current, board fit and local wiring rules before ordering.

Applications and Selection Guide

Use the product-specific values below as a shortlist, then validate the complete circuit design. Product ratings do not replace a fault-current study, conductor calculation, coordination review or applicable installation rules.

Selection point FB2HL-63 option What the project must confirm
Protection function Overload, short circuit and residual current Do not substitute an MCB where residual-current protection is required
Residual-current data Type AC; IΔn 30mA; IΔm 2,000A Confirm waveform type and sensitivity against the circuit and local rules
Rated current and curve 10A–63A; C curve Coordinate with conductor ampacity and load inrush
Fault interruption 10kA Icu; 7.5kA Ics Prospective short-circuit current must not exceed the applicable rating
Board fit Plug-in mounting Confirm compatible base, dimensions, connection arrangement and maintenance space

Breaking Capacity

10kA Icu; 7.5kA Ics is the published product value. Confirm the prospective short-circuit current at the installation point.

Fault LevelProject Selection

Trip and Load Behaviour

C is the available trip/protection option. Match it to load inrush and required disconnection performance.

Load InrushProject Selection

Pole Configuration

Available arrangement: 1P+N / 2P. Confirm which conductors must be switched and protected under local rules.

Circuit LayoutProject Selection

RCBO Protection Function

This model adds Type AC 30mA residual-current protection to overcurrent protection.

Protection ScopeProject Selection

Ordering Guide

  1. Specify the exact model: FB2HL-63.
  2. State the required current rating within 10A–63A.
  3. Confirm pole arrangement: 1P+N / 2P.
  4. Confirm trip or protection option: C.
  5. Provide system voltage, expected fault level, destination market, quantity and any document requirements.

Installation and Coordination Checks

  • Verify conductor material and cross-section against the circuit calculation and the published terminal range.
  • Confirm the prospective short-circuit current does not exceed the applicable breaking rating.
  • Check upstream/downstream coordination, enclosure temperature, grouping, altitude and required clearances.
  • Installation, isolation, testing and maintenance must be carried out by qualified personnel under applicable rules.

Type designation

Tripping curves

Dimensions(mm)

Technical Specifications

Parameter  
Bracket rating current 50/63A
Number of poles 1P+N/2P
Feature Overload and short circuit protection
Rated frequency f(HZ) 50/60Hz
Leakage trip mode Electronic formula
Leakage type Type AC
Rated operating voltage Ue(V AC) 240V~
Rated current In(A) 10,16,20,25,32,40,50,63A
Rated insulation voltage Ui(V) 500V
Rated impulse withstand voltage Uimp(kA) 4kV
Rated residual current IΔn 30mA
Rated remaining making and breaking capacity IΔm 2000A
Rated operating short-circuit breaking capacity (KA) 7.5 kA
Rated limit short-circuit breaking capacity (kA) 10kA
Current limiting class 3
Instantaneous trip characteristics Electromagnetic type
Trip type C
Electrical service life 4000 times
Service life of machinery 10000 times
Class of protection IP20
Wiring capability (mm2) 1 to 25mm2
Ambient temperature (daily average) 35 ℃ or less
Storage temperature -25℃ to +55℃
Types of climate protection Damp-heat type
Altitude (m) ≤2000m
Relative humidity of air 50% ~ 90%
Pollution level 2
Installation environment B
Installation category Ⅱ or Ⅲ
Installation mode plug-in
Meet the standard IEC 61009-1

Why Choose CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.


30+

YEARS EXPERIENCE

Specialized in low-voltage electrical manufacturing


1100+

EMPLOYEES

Professional team ensures stable quality and delivery


100M+

POLES ANNUAL CAPACITY

Large-scale production capacity to meet global demand


90%

AUTOMATED PRODUCTION

Advanced automation for high efficiency and consistency

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

IEC Certification
CE Certification
CB Certification
RoHS Certification
ISO 14001 Certification

Strict quality control system ensures every product meets global standards.

What Can We Customize?

For FB2HL-63 projects, CHAC can review private-label marking, packaging, appearance, available electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, MOQ and project feasibility.

Logo & Branding

Private-label marking and nameplate options are subject to artwork review and sample approval.

Logo & Branding

Packaging
Customization

Cartons, labels and manuals can be prepared for the approved order specification and destination market.

Packaging Customization

Electrical
Customization

Select from the published 10A–63A, 1P+N / 2P and C options; non-standard requests require technical evaluation.

Electrical Customization

Product
Appearance

Appearance options can be reviewed subject to tooling, MOQ, marking requirements and technical feasibility.

Product Appearance

Certification
Support

Datasheets, drawings and verified certificate information are supplied for the applicable approved configuration.

Certification Support

Engineering
Development

Project support may include drawing review, sample evaluation, testing and production planning, subject to technical approval.

Engineering Development

Download

PDF

FB Series Miniature Circuit Breaker

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Contact Us

FB2HL-63 Product FAQ

What does 30mA mean on the FB2HL-63 RCBO?

30mA is the published rated residual operating current, IΔn. It is separate from the 10A–63A rated-current options used for overload and conductor protection.

What is the difference between a 30mA and 100mA RCBO?

The residual operating threshold differs, which affects the intended protection and coordination. FB2HL-63 is published as 30mA; do not substitute another sensitivity without checking the design and local rules.

What is a 30mA RCBO?

It combines overload and short-circuit protection with residual-current protection at a published 30mA IΔn. FB2HL-63 is Type AC and uses plug-in mounting, so waveform suitability and panel fit must also be confirmed.

Is an RCBO better than an RCD?

They perform different roles. An RCBO combines residual-current and overcurrent protection for a circuit, while an RCD may provide residual-current protection for multiple downstream circuits and requires suitable overcurrent protection.

What is a disadvantage of using an RCBO?

An RCBO must match more parameters—rated current, curve, residual-current type and sensitivity, poles, breaking capacity and board fit. Incorrect selection can create compatibility or protection gaps.

Which is more sensitive, 30mA or 100mA?

30mA is the lower residual operating-current value and is therefore more sensitive numerically. The required sensitivity must still be selected from the protection objective, coordination and applicable local rules.

Confirm the Right FB2HL-63 Configuration

Send your current rating, pole arrangement, trip option, system voltage, prospective fault level, destination market and quantity. CHAC will review the request against the published product range.

Request a Quote