FB2HL-63 Bộ ngắt mạch dòng dư với chức năng bảo vệ quá dòng – Loại điện từ
Phần FB2HL-63 RCBO provides overload, short-circuit and residual-current protection within the published 10A–63A range. Its verified product data lists 10kA Icu; 7.5kA Ics, 1P+N / 2P and C. Final selection must match the conductor, load, prospective fault current, installation system and applicable local rules.
Giới thiệu sản phẩm
FB2HL-63 is a plug-in residual current circuit breaker with integral overcurrent protection for 240V AC systems. It combines C-curve overload and short-circuit protection with Type AC, 30mA residual-current protection. It should be selected as an RCBO, not as an MCB with implied leakage protection.
The model data references IEC 61009-1. Standards, certification scope and technical documents must be confirmed for the ordered configuration and destination market.
Tính năng chính
Các ứng dụng điển hình
Typical projects include compatible single-phase distribution boards where combined overcurrent and residual-current protection is specified. Confirm the expected residual-current waveform, required sensitivity, conductor size, prospective fault current, board fit and local wiring rules before ordering.
Hướng dẫn đăng ký và tuyển chọn
Hãy sử dụng các giá trị cụ thể cho từng sản phẩm dưới đây làm danh sách lựa chọn, sau đó xác nhận lại toàn bộ thiết kế mạch. Các đánh giá về sản phẩm không thay thế cho việc nghiên cứu về dòng điện quá tải, tính toán dây dẫn, đánh giá phối hợp hoặc các quy tắc lắp đặt áp dụng.
| Điểm lựa chọn | FB2HL-63 option | Những gì dự án phải xác nhận |
|---|---|---|
| Protection function | Overload, short circuit and residual current | Do not substitute an MCB where residual-current protection is required |
| Residual-current data | Type AC; IΔn 30mA; IΔm 2,000A | Confirm waveform type and sensitivity against the circuit and local rules |
| Rated current and curve | 10A–63A; C curve | Coordinate with conductor ampacity and load inrush |
| Fault interruption | Bộ phận bảo vệ Icu 10kA; Bộ phận bảo vệ Ics 7.5kA | Prospective short-circuit current must not exceed the applicable rating |
| Board fit | Cắm vào đế | Confirm compatible base, dimensions, connection arrangement and maintenance space |
Giới hạn khả năng chịu tải
10kA Icu; 7.5kA Ics is the published product value. Confirm the prospective short-circuit current at the installation point.
Hành vi di chuyển và tải trọng
C is the available trip/protection option. Match it to load inrush and required disconnection performance.
Cấu hình cực
Available arrangement: 1P+N / 2P. Confirm which conductors must be switched and protected under local rules.
RCBO Protection Function
This model adds Type AC 30mA residual-current protection to overcurrent protection.
Hướng dẫn đặt hàng
- Specify the exact model: FB2HL-63.
- State the required current rating within 10A–63A.
- Confirm pole arrangement: 1P+N / 2P.
- Confirm trip or protection option: C.
- Cung cấp điện áp hệ thống, mức độ lỗi dự kiến, thị trường đích, số lượng và bất kỳ yêu cầu tài liệu nào.
Kiểm tra lắp đặt và phối hợp
- Kiểm tra vật liệu dẫn và hình dạng của đường dẫn so với tính toán mạch và phạm vi đầu nối được công bố.
- Xác nhận rằng dòng điện ngắn mạch dự kiến không vượt quá cấp điện được quy định.
- Kiểm tra sự phối hợp giữa các phần trên và dưới, nhiệt độ của thùng chứa, cách bố trí, độ cao và khoảng cách cần thiết.
- Việc lắp đặt, cách ly, thử nghiệm và bảo trì phải được thực hiện bởi nhân viên có trình độ chuyên môn theo quy định hiện hành.
Tên loại

Các đường cong khi va chạm

Kích thước (mm)

Đặc điểm kỹ thuật
| Tham số | |
| Bracket rating current | 50/63A |
| Number of poles | 1P+N/2P |
| Feature | Overload and short circuit protection |
| Rated frequency f(HZ) | 50/60Hz |
| Leakage trip mode | Electronic formula |
| Leakage type | Loại AC |
| Rated operating voltage Ue(V AC) | 240V~ |
| Rated current In(A) | 10,16,20,25,32,40,50,63A |
| Rated insulation voltage Ui(V) | 500V |
| Rated impulse withstand voltage Uimp(kA) | 4kV |
| Rated residual current IΔn | 30mA |
| Rated remaining making and breaking capacity IΔm | 2000A |
| Rated operating short-circuit breaking capacity (KA) | 7.5 kA |
| Rated limit short-circuit breaking capacity (kA) | 10kA |
| Current limiting class | 3 |
| Instantaneous trip characteristics | Electromagnetic type |
| Trip type | C |
| Electrical service life | 4000 times |
| Service life of machinery | 10000 times |
| Class of protection | IP20 |
| Wiring capability (mm2) | 1 to 25mm2 |
| Ambient temperature (daily average) | 35 ℃ or less |
| Storage temperature | -25℃ to +55℃ |
| Types of climate protection | Damp-heat type |
| Altitude (m) | ≤2000m |
| Relative humidity of air | 50% ~ 90% |
| Pollution level | 2 |
| Installation environment | B |
| Installation category | Ⅱ or Ⅲ |
| Installation mode | plug-in |
| Meet the standard | IEC 61009-1 |
Tại sao nên chọn CHAC
With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.
30+
NĂM KINH NGHIỆM
Chuyên sản xuất thiết bị điện hạ thế
1100+
CÔNG NHÂN
Đội ngũ chuyên nghiệp đảm bảo chất lượng và giao hàng ổn định
100 triệu người
Sức chứa hàng năm của các cột
Năng lực sản xuất quy mô lớn để đáp ứng nhu cầu toàn cầu
90%
SẢN XUẤT TỰ ĐỘNG
Tự động hóa nâng cao cho hiệu quả cao và tính nhất quán

Dây chuyền lắp ráp tự động

Phòng thí nghiệm kiểm nghiệm

Xay và dập

Kiểm tra chất lượng





Strict quality control system ensures every product meets global standards.
Chúng tôi có thể tùy chỉnh những gì?
For FB2HL-63 projects, CHAC can review private-label marking, packaging, appearance, available electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, MOQ and project feasibility.
Logo & Thương hiệu
Private-label marking and nameplate options are subject to artwork review and sample approval.

Gói bao bì
Tùy chỉnh
Cartons, labels and manuals can be prepared for the approved order specification and destination market.

Điện
Tùy chỉnh
Select from the published 10A–63A, 1P+N / 2P and C options; non-standard requests require technical evaluation.

Sản phẩm
Vẻ ngoài
Appearance options can be reviewed subject to tooling, MOQ, marking requirements and technical feasibility.

Chứng nhận
Hỗ trợ
Datasheets, drawings and verified certificate information are supplied for the applicable approved configuration.

Kỹ thuật
Phát triển
Project support may include drawing review, sample evaluation, testing and production planning, subject to technical approval.

Tải xuống
Bộ ngắt mạch cỡ nhỏ FB Series
Complete product overview for low-voltage electrical components and product selection reference.
Cần tài liệu kỹ thuật?
Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.
FB2HL-63 Product FAQ
What does 30mA mean on the FB2HL-63 RCBO?
30mA is the published rated residual operating current, IΔn. It is separate from the 10A–63A rated-current options used for overload and conductor protection.
What is the difference between a 30mA and 100mA RCBO?
The residual operating threshold differs, which affects the intended protection and coordination. FB2HL-63 is published as 30mA; do not substitute another sensitivity without checking the design and local rules.
What is a 30mA RCBO?
It combines overload and short-circuit protection with residual-current protection at a published 30mA IΔn. FB2HL-63 is Type AC and uses plug-in mounting, so waveform suitability and panel fit must also be confirmed.
Is an RCBO better than an RCD?
They perform different roles. An RCBO combines residual-current and overcurrent protection for a circuit, while an RCD may provide residual-current protection for multiple downstream circuits and requires suitable overcurrent protection.
What is a disadvantage of using an RCBO?
An RCBO must match more parameters—rated current, curve, residual-current type and sensitivity, poles, breaking capacity and board fit. Incorrect selection can create compatibility or protection gaps.
Which is more sensitive, 30mA or 100mA?
30mA is the lower residual operating-current value and is therefore more sensitive numerically. The required sensitivity must still be selected from the protection objective, coordination and applicable local rules.
Confirm the Right FB2HL-63 Configuration
Send your current rating, pole arrangement, trip option, system voltage, prospective fault level, destination market and quantity. CHAC will review the request against the published product range.