FB2HL-63 Pemutus Sirkuit Arus Sisa dengan Perlindungan Overcurrernt – Jenis Elektromagnetik

Itu FB2HL-63 RCBO provides overload, short-circuit and residual-current protection within the published 10A–63A range. Its verified product data lists 10kA Icu; 7.5kA Ics, 1P+N / 2P and C. Final selection must match the conductor, load, prospective fault current, installation system and applicable local rules.

Polandia:
1P+N / 2P
Nilai arus:
10A–63A
Rating Listrik:
AC 240V
Frekvens:
50/60Hz
Pengecekan Data:
10kA Icu; 7.5kA Ics
Jenis Perjalanan / Residual:
C
Standar:
IEC 61009-1
Pemasangan:
Penempatan plug-in

Gambaran Produk

FB2HL-63 is a plug-in residual current circuit breaker with integral overcurrent protection for 240V AC systems. It combines C-curve overload and short-circuit protection with Type AC, 30mA residual-current protection. It should be selected as an RCBO, not as an MCB with implied leakage protection.

The model data references IEC 61009-1. Standards, certification scope and technical documents must be confirmed for the ordered configuration and destination market.

Fitur Utama

  • Published current range: 10A–63A.
  • Pole configuration: 1P+N / 2P.
  • Trip / protection option: C.
  • Short-circuit data: 10kA Icu; 7.5kA Ics.
  • Electrical reference: 240V AC, 50/60Hz.
  • Service-life data: 10,000 mechanical and 4,000 electrical operations.
  • Additional verified data: Type AC; IΔn 30mA; IΔm 2,000A; 500V Ui; 4kV Uimp; IP20; 1–25mm² conductors.

Aplikasi Biasa

Typical projects include compatible single-phase distribution boards where combined overcurrent and residual-current protection is specified. Confirm the expected residual-current waveform, required sensitivity, conductor size, prospective fault current, board fit and local wiring rules before ordering.

Permohonan dan Panduan Pemilihan

Use the product-specific values below as a shortlist, then validate the complete circuit design. Product ratings do not replace a fault-current study, conductor calculation, coordination review or applicable installation rules.

Titik pemilihan FB2HL-63 option Hal yang harus dipastikan oleh proyek tersebut
Protection function Overload, short circuit and residual current Do not substitute an MCB where residual-current protection is required
Residual-current data Type AC; IΔn 30mA; IΔm 2,000A Confirm waveform type and sensitivity against the circuit and local rules
Rated current and curve 10A–63A; C curve Coordinate with conductor ampacity and load inrush
Fault interruption 10kA Icu; 7.5kA Ics Prospective short-circuit current must not exceed the applicable rating
Board fit Penempatan plug-in Confirm compatible base, dimensions, connection arrangement and maintenance space

Breaking Capacity

10kA Icu; 7.5kA Ics is the published product value. Confirm the prospective short-circuit current at the installation point.

Fault LevelPemilihan Proyek

Trip and Load Behaviour

C is the available trip/protection option. Match it to load inrush and required disconnection performance.

Load InrushPemilihan Proyek

Pole Configuration

Available arrangement: 1P+N / 2P. Confirm which conductors must be switched and protected under local rules.

Circuit LayoutPemilihan Proyek

RCBO Protection Function

This model adds Type AC 30mA residual-current protection to overcurrent protection.

Protection ScopePemilihan Proyek

Panduan Pemesanan

  1. Specify the exact model: FB2HL-63.
  2. State the required current rating within 10A–63A.
  3. Confirm pole arrangement: 1P+N / 2P.
  4. Confirm trip or protection option: C.
  5. Provide system voltage, expected fault level, destination market, quantity and any document requirements.

Pengujian Instalasi dan Koordinasi

  • Verify conductor material and cross-section against the circuit calculation and the published terminal range.
  • Confirm the prospective short-circuit current does not exceed the applicable breaking rating.
  • Check upstream/downstream coordination, enclosure temperature, grouping, altitude and required clearances.
  • Installation, isolation, testing and maintenance must be carried out by qualified personnel under applicable rules.

Penamaan tipe

Fb2Hl 63 Residual Current Circuit Breaker With Overcurrernt Protection Electromagnetic Type product image

Tripping curves

Fb2Hl 63 Residual Current Circuit Breaker With Overcurrernt Protection Electromagnetic Type product image

Dimensi (mm)

Fb2Hl 63 Residual Current Circuit Breaker With Overcurrernt Protection Electromagnetic Type product image

Spesifikasi Teknis

Parameter  
Bracket rating current 50/63A
Number of poles 1P+N/2P
Feature Overload and short circuit protection
Rated frequency f(HZ) 50/60Hz
Leakage trip mode Electronic formula
Leakage type Jenis AC
Rated operating voltage Ue(V AC) 240V~
Rated current In(A) 10,16,20,25,32,40,50,63A
Rated insulation voltage Ui(V) 500V
Rated impulse withstand voltage Uimp(kA) 4kV
Rated residual current IΔn 30mA
Rated remaining making and breaking capacity IΔm 2000A
Rated operating short-circuit breaking capacity (KA) 7.5 kA
Rated limit short-circuit breaking capacity (kA) 10kA
Current limiting class 3
Instantaneous trip characteristics Electromagnetic type
Trip type C
Electrical service life 4000 times
Service life of machinery 10000 times
Class of protection IP20
Wiring capability (mm2) 1 to 25mm2
Ambient temperature (daily average) 35 ℃ or less
Storage temperature -25℃ to +55℃
Types of climate protection Damp-heat type
Altitude (m) ≤2000m
Relative humidity of air 50% ~ 90%
Pollution level 2
Installation environment B
Installation category Ⅱ or Ⅲ
Installation mode plug-in
Meet the standard IEC 61009-1

Mengapa Memilih CHAC

Dengan pengalaman manufaktur lebih dari 30 tahun, 1100+ karyawan, dan 100M+ tiang
kapasitas tahunan dan produksi otomatis 90% unit, CHAC memberikan kapasitas produksi yang stabil dan ketat
Pengendalian kualitas untuk pelanggan OEM/ODM global. Sistem manufaktur internal kami mendukung jangka panjang
Kerjasama untuk merek-merek listrik, importir dan distributor.

Gambar produk pemutus sirkuit udara seri Cqw2
30+

BERKALI-KALI BERKEMBANG

Mengkhususkan diri dalam manufaktur listrik tegangan rendah

Gambar produk pemutus sirkuit udara seri Cqw2
1100+

KARYAWAN

Tim profesional memastikan kualitas dan pengiriman yang stabil

Gambar produk pemutus sirkuit udara seri Cqw2
100 juta+

Kapasitas Bulanan POKER

Kapasitas produksi berskala besar untuk memenuhi permintaan global

Gambar produk pemutus sirkuit udara seri Cqw2
90%

PENGELOLAAN PRODUKSI AUTOMATIS

Otomasi canggih untuk efisiensi dan konsistensi yang tinggi

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image

Barisan Perakitan Otomatis

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image

Laboratorium Pengujian

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image

Injeksi & Stamping

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image

Pemeriksaan Kualitas

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image
FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image
FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image
FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image
FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image

Sistem kontrol kualitas yang ketat memastikan setiap produk memenuhi standar global.

Apa yang Dapat Kami Sesuaikan?

For FB2HL-63 projects, CHAC can review private-label marking, packaging, appearance, available electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, MOQ and project feasibility.

Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Logo & Branding

Pilihan penandaan merek pribadi dan plakat nama tunduk pada pemeriksaan karya seni dan persetujuan sampel.

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Kemasan
Kustomisasi

Kotak karton, label, dan manual dapat disiapkan sesuai spesifikasi pesanan yang telah disetujui dan pasar tujuan.

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Elektrik
Kustomisasi

Select from the published 10A–63A, 1P+N / 2P and C options; non-standard requests require technical evaluation.

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Produk
Penampilan

Pilihan tampilan dapat ditinjau kembali berdasarkan ketersediaan alat, minimum order pembelian (MOQ), persyaratan penandaan, dan kelayakan teknis.

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Sertifikasi
Dukungan

Datasheets, drawings and verified certificate information are supplied for the applicable approved configuration.

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Teknologi
Pembangunan

Penunjang proyek dapat mencakup review desain, evaluasi sampel, pengujian, dan perencanaan produksi, dengan ketentuan persetujuan teknis.

FB2HL-63 Residual Current Circuit Breaker with Overcurrernt Protection - Electromagnetic Type product image

Unduh

PDF

Pemutus Sirkuit Miniatur Seri FB

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Butuh Dokumen Teknis?

Hubungi kami untuk mendapatkan data spesifikasi, sertifikat, gambar, panduan pemilihan, atau dukungan proyek OEM/ODM.

Hubungi Kami

FB2HL-63 Product FAQ

What does 30mA mean on the FB2HL-63 RCBO?

30mA is the published rated residual operating current, IΔn. It is separate from the 10A–63A rated-current options used for overload and conductor protection.

What is the difference between a 30mA and 100mA RCBO?

The residual operating threshold differs, which affects the intended protection and coordination. FB2HL-63 is published as 30mA; do not substitute another sensitivity without checking the design and local rules.

What is a 30mA RCBO?

It combines overload and short-circuit protection with residual-current protection at a published 30mA IΔn. FB2HL-63 is Type AC and uses plug-in mounting, so waveform suitability and panel fit must also be confirmed.

Is an RCBO better than an RCD?

They perform different roles. An RCBO combines residual-current and overcurrent protection for a circuit, while an RCD may provide residual-current protection for multiple downstream circuits and requires suitable overcurrent protection.

What is a disadvantage of using an RCBO?

An RCBO must match more parameters—rated current, curve, residual-current type and sensitivity, poles, breaking capacity and board fit. Incorrect selection can create compatibility or protection gaps.

Which is more sensitive, 30mA or 100mA?

30mA is the lower residual operating-current value and is therefore more sensitive numerically. The required sensitivity must still be selected from the protection objective, coordination and applicable local rules.

Confirm the Right FB2HL-63 Configuration

Send your current rating, pole arrangement, trip option, system voltage, prospective fault level, destination market and quantity. CHAC will review the request against the published product range.

Minta Penawaran Harga