PXL9-63 Series Electromagnetic Leakage Circuit Breaker

Der PXL9-63 is specified for residual-current protection without overcurrent protection. Select it using the published voltage, current, pole and protection data, then confirm conductor coordination, fault conditions, enclosure requirements and local installation rules.

Polen:
2P / 4P
Nennstrom:
6–63A
Nennspannung:
AC 230/400V
Hauptfunktion:
residual-current protection without overcurrent protection
Auswahldaten:
30mA, 100mA or 300mA options
Standard
IEC 61008-1 family references

Product Overview

PXL9-63 is a 63A RCCB for AC 230/400V applications. It is intended for residential, commercial and industrial circuits where a separate overcurrent device is coordinated; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.

residual-current protection without overcurrent protection is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.

Key Features

  • Published pole options: 2P / 4P.
  • Published electrical context: AC 230/400V.
  • Primary function: residual-current protection without overcurrent protection.
  • Selection reference: 30mA, 100mA or 300mA options.
  • Applicable standard reference: IEC 61008-1 family references.
  • Final selection must use the exact model table, drawings and installation instructions.

Typische Anwendungen

residential, commercial and industrial circuits where a separate overcurrent device is coordinated. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.

Applications and Selection Guide

Use the verified PXL9-63 records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.

Selection point PXL9-63 reference What the project must confirm
Rated current Use the exact model table Design current, conductor capacity, ambient and grouping
Voltage and frequency AC 230/400V Supply system and equipment rating
Masten 2P / 4P Conductors to be switched, protected or isolated
Protection / control residual-current protection without overcurrent protection Required function and adjacent-device coordination
Fault / residual data 30mA, 100mA or 300mA options Prospective short-circuit or leakage conditions

RCCB vs RCBO

An RCCB addresses residual-current protection; an RCBO combines residual-current and overcurrent functions. Choose the architecture required by the protection study.

Protection Function
Compare RCBO Options →

Model-Specific Ratings

Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.

Verified Data
View Technical Support →

Installation and Coordination

Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.

Engineering Check
Discuss a Configuration →

Ordering Information

State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.

Project Inputs
Send Project Details →

Ordering Guide

  1. State the exact model: PXL9-63.
  2. Provide rated current and voltage from the published technical table.
  3. Confirm poles and the required protection, isolation or control function.
  4. Provide application, expected fault/leakage conditions, destination market and quantity.
  5. List accessory, terminal, documentation and approved marking or packaging requirements.

Installation and Coordination Checks

  • Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
  • Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
  • Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
  • Installation, testing and maintenance must be completed by qualified personnel under applicable rules.

Type designation

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image

Dimension

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image

Technical Specifications

Parameter
Rated voltage Ue 230V/400V
Rated current(A) 6, 10, 16, 20, 25, 32, 40, 50, 63
Rated insulation voltage(Ui) 500V
Rated frequency 50Hz/60Hz
Number of poles 2P、4P
Rated limited short-circuit current Inc(A) 6000
Rated limited residual short-circuit current I△c(A) 6000
Mechanical&Electrical life 4000
Rated residual operating current I△n(mA) 30, 100, 300
Pollution degree 2
Protection degree IP20
Standards EN/IEC61008-1、GB/T16916.1
Tighten torque(Nm) 2.5
Rated impulse withstand voltage(Uimp) 4000V
Type of residual current AC、A、B、S、G
Rated making&breaking capacity Im(A) 500A or 10In (Take the maximum value)
Rated residual making&breaking capacity I△m(A) 500A or 10In (Take the maximum value)

Warum CHAC wählen?

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.

Cqw2 Series Air Circuit Breaker product image
30+

JAHRE ERFAHRUNG

Specialisiert auf die Herstellung von Niederspannungselektronik

Cqw2 Series Air Circuit Breaker product image
1100+

ARBEITER

Das professionelle Team gewährleistet eine stabile Qualität und Lieferfähigkeit.

Cqw2 Series Air Circuit Breaker product image
100 Millionen+

JAHRESTERNE VON POLES

Großserienfertigung zur Deckung der weltweiten Nachfrage

Cqw2 Series Air Circuit Breaker product image
90%

AUTOMATISCHE PRODUZIERUNG

Erweiterte Automatisierung für hohe Effizienz und Konsistenz

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image

Automatisierte Montagelinie

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image

Testlabor

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image

Injektion und Stempeln

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image

Qualitätskontrolle

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image
PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image
PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image
PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image
PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image

Strict quality control system ensures every product meets global standards.

Was können wir anpassen?

For PXL9-63 projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.

Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Logo & Branding

Kundenspezifische Logo-Bedruckung, Lasermarkierung und Namensschild-Lösungen.

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Verpackung
Anpassung

Kundenspezifische Farbkartons, Kartons, Etiketten und Handbücher.

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Elektrisch
Anpassung

Current, voltage, breaking capacity, trip curve and other
special functions.

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Produkt
Aussehen

Anpassung der Wohnungsfarbe, des Griffs und des Erscheinungsbildes.

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Zertifizierung
Support

Products comply with international standards and market
requirements.

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Ingenieurwesen
Entwicklung

Auswertung der Zeichnungen, Prototypentest und Massenfertigung.

PXL9-63 Series Electromagnetic Leakage Circuit Breaker product image

Herunterladen

PDF

PXB9-Serie Miniatur-Schutzschalter

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Kontaktieren Sie uns

PXL9-63 Product FAQ

What is the PXL9-63 used for?

The PXL9-63 is specified for residual-current protection without overcurrent protection in AC 230/400V applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.

How does the PXL9-63 work?

Its operating principle follows the documented function: residual-current protection without overcurrent protection. Use the exact model documentation for thresholds, timing, trip behaviour, terminals and test procedures.

How do I choose the PXL9-63 rating and poles?

Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 2P / 4P; confirm neutral, polarity, conductors and isolation requirements.

What safety limitation applies to the PXL9-63?

Do not treat the PXL9-63 as a universal substitute for another device. Confirm 30mA, 100mA or 300mA options, the system voltage, fault or leakage conditions and any separate upstream protection before selection.

Can the PXL9-63 be used in another circuit type?

Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.

How should the PXL9-63 be installed and tested?

Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.

Confirm the Right PXL9-63 Configuration

Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.

Angebot anfordern