PXL9-63 Series Electromagnetic Leakage Circuit Breaker
Le PXL9-63 is specified for residual-current protection without overcurrent protection. Select it using the published voltage, current, pole and protection data, then confirm conductor coordination, fault conditions, enclosure requirements and local installation rules.
Vue d'ensemble du produit
PXL9-63 is a 63A RCCB for AC 230/400V applications. It is intended for residential, commercial and industrial circuits where a separate overcurrent device is coordinated; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.
residual-current protection without overcurrent protection is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.
Principales caractéristiques
Applications typiques
residential, commercial and industrial circuits where a separate overcurrent device is coordinated. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.
Demandes d’admission et guide de sélection
Use the verified PXL9-63 records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.
| Point de sélection | PXL9-63 reference | Ce que le projet doit confirmer |
|---|---|---|
| Rated current | Use the exact model table | Design current, conductor capacity, ambient and grouping |
| Voltage and frequency | AC 230/400V | Supply system and equipment rating |
| Pôles | 2P / 4P | Conductors to be switched, protected or isolated |
| Protection / control | residual-current protection without overcurrent protection | Required function and adjacent-device coordination |
| Fault / residual data | 30mA, 100mA or 300mA options | Prospective short-circuit or leakage conditions |
RCCB vs RCBO
An RCCB addresses residual-current protection; an RCBO combines residual-current and overcurrent functions. Choose the architecture required by the protection study.
Protection Function
Compare RCBO Options →
Model-Specific Ratings
Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.
Verified Data
View Technical Support →
Installation and Coordination
Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.
Engineering Check
Discuss a Configuration →
Ordering Information
State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.
Project Inputs
Send Project Details →
Guide d'achat
- State the exact model: PXL9-63.
- Provide rated current and voltage from the published technical table.
- Confirm poles and the required protection, isolation or control function.
- Provide application, expected fault/leakage conditions, destination market and quantity.
- List accessory, terminal, documentation and approved marking or packaging requirements.
Installation and Coordination Checks
- Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
- Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
- Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
- Installation, testing and maintenance must be completed by qualified personnel under applicable rules.
Type designation

Dimension

Technical Specifications
| Parameter | |
| Rated voltage Ue | 230V/400V |
| Rated current(A) | 6, 10, 16, 20, 25, 32, 40, 50, 63 |
| Rated insulation voltage(Ui) | 500V |
| Rated frequency | 50Hz/60Hz |
| Number of poles | 2P、4P |
| Rated limited short-circuit current Inc(A) | 6000 |
| Rated limited residual short-circuit current I△c(A) | 6000 |
| Mechanical&Electrical life | 4000 |
| Rated residual operating current I△n(mA) | 30, 100, 300 |
| Pollution degree | 2 |
| Protection degree | IP20 |
| Standards | EN/IEC61008-1、GB/T16916.1 |
| Tighten torque(Nm) | 2.5 |
| Rated impulse withstand voltage(Uimp) | 4000V |
| Type of residual current | AC、A、B、S、G |
| Rated making&breaking capacity Im(A) | 500A or 10In (Take the maximum value) |
| Rated residual making&breaking capacity I△m(A) | 500A or 10In (Take the maximum value) |
Pourquoi choisir CHAC
With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.
30+
ANNÉE D'EXPÉRIENCE
Spécialisée dans la fabrication d'appareils électriques à faible tension
1100+
EMPLOYÉS
Une équipe professionnelle garantit une qualité et une livraison stables
100 millions d'euros
Capacité annuelle des poteaux
Capacité de production à grande échelle pour répondre à la demande mondiale
90%
PRODUCTION AUTOMATIQUE
Une automatisation avancée pour une efficacité et une cohérence élevées

Ligne de montage automatisée

Laboratoire d'essai

Injection et estampage

Inspection de qualité





Strict quality control system ensures every product meets global standards.
Qu'est-ce que nous pouvons personnaliser ?
For PXL9-63 projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.
Logo et identité visuelle
Solutions d'impression de logos personnalisés, marquage laser et plaques d'identification.

Emballage
Personnalisation
Boîtes, cartons, étiquettes et manuels de couleurs personnalisés.

Électrique
Personnalisation
Current, voltage, breaking capacity, trip curve and other
special functions.

Produit
Apparence
Personnalisation de la couleur de l’habillage, de la poignée et de l’apparence.

Certification
Support
Products comply with international standards and market
requirements.

Ingénierie
Développement
Évaluation des dessins, test des prototypes et production en série.

Télécharger
Disjoncteur miniature de la série PXB9
Complete product overview for low-voltage electrical components and product selection reference.
Need Technical Documents?
Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.
PXL9-63 Product FAQ
What is the PXL9-63 used for?
The PXL9-63 is specified for residual-current protection without overcurrent protection in AC 230/400V applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.
How does the PXL9-63 work?
Its operating principle follows the documented function: residual-current protection without overcurrent protection. Use the exact model documentation for thresholds, timing, trip behaviour, terminals and test procedures.
How do I choose the PXL9-63 rating and poles?
Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 2P / 4P; confirm neutral, polarity, conductors and isolation requirements.
What safety limitation applies to the PXL9-63?
Do not treat the PXL9-63 as a universal substitute for another device. Confirm 30mA, 100mA or 300mA options, the system voltage, fault or leakage conditions and any separate upstream protection before selection.
Can the PXL9-63 be used in another circuit type?
Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.
How should the PXL9-63 be installed and tested?
Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.
Confirm the Right PXL9-63 Configuration
Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.