Interruptor Automático de Protección de Motores Serie CQV2

El Interruptor Automático de Protección de Motores Serie CQV2 is a CHAC motor protection circuit breaker for overload, phase-failure and short-circuit protection. The page keeps the model-specific technical table and original product images so buyers can verify voltage, current, configuration, mounting and applicable standards before ordering. Final suitability depends on the complete circuit, installation method and destination-market rules.

Product family:
Protector de motor
Primary function:
overload, phase-failure and short-circuit protection
Typical context:
three-phase motors, pumps and machine feeders
Technical data:
See verified model table below
Configuration:
Confirm the exact model variant
Support:
OEM/ODM review available

Descripción del producto

CQV2 Series Motor Protection Circuit Breaker is a motor protection circuit breaker intended for overload, phase-failure and short-circuit protection. The current product record identifies it for three-phase motors, pumps and machine feeders. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.

Verified source summary: Type Designation Tripping Characteristic Curve Test condition: Ambient temperature 20℃ Curve parameters (based on multiples of setting current in): (1) Starting from cold state, 3-pole (2) Starting from cold state, 2-pole (3) Starting from hot state, 3-pole Dimensions (mm) CQV2-ME CQV-AU/AX/AS CQV-AN/AD/AM CQV-AE Circuit Shield Technical Specifications Product Model Rated current(A) Motor output(kW) Setting Range(A)

Características clave

  • Product type: motor protection circuit breaker.
  • Primary function: overload, phase-failure and short-circuit protection.
  • Application context: three-phase motors, pumps and machine feeders.
  • Model variants, dimensions and ratings remain in the preserved technical source.
  • Confirm installation method, environmental limits and local compliance before release.

Aplicaciones típicas

Typical use can include three-phase motors, pumps and machine feeders when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.

Guía de Solicitudes y Selección

Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.

Punto de selección Interruptor Automático de Protección de Motores Serie CQV2 Lo que el proyecto debe confirmar
Solicitud Motor Protector projects Confirm the actual system and environment
Selection basis overload, phase-failure and short-circuit protection Use the exact model and technical table
Instalación Follow the model instructions Check mounting, clearances and termination
Cumplimiento Use the listed standard where applicable Verify edition, scope and destination rules
Adjacent product Evaluate the related CHAC family where function differs Do not substitute without engineering review

Function

overload, phase-failure and short-circuit protection

Match the protection or switching function to the system.

View related guidance →

Configuración

Model-specific options

Confirm current, voltage, poles, terminals or accessories from the table.

View related guidance →

Instalación

Mechanical and electrical fit

Check enclosure, mounting, wiring space and maintenance access.

View related guidance →

Project evidence

Documents and test records

Retain the approved drawing, technical sheet and commissioning record.

View related guidance →

Guía de pedidos

  1. State the exact model and variant.
  2. Provide the system voltage, current, frequency and load or protection function.
  3. Confirm mounting, terminals, accessories, enclosure and environmental conditions.
  4. Share quantity, destination market and required technical documents.

Comprobaciones de Instalación y Coordinación

  • Verify the model’s ratings and connection arrangement against the project drawings.
  • Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
  • Coordinate upstream and downstream protection or control devices where applicable.
  • Use qualified personnel for installation, testing, isolation and maintenance.

Type Designation

Tripping Characteristic Curve

Test condition: Ambient temperature 20℃

Curve parameters (based on multiples of setting current in):

(1) Starting from cold state, 3-pole

(2) Starting from cold state, 2-pole

(3) Starting from hot state, 3-pole

Dimensiones (mm)

CQV2-ME

CQV-AU/AX/AS      CQV-AN/AD/AM     CQV-AE

Circuit Shield

Especificaciones técnicas

Modelo de producto Rated current(A) Motor output(kW) Setting Range(A) Order Number Packing parameters
CQV2-ME32 Thermal overload releases

Instantaneous overcurrent releases

QTY:50PCS
N.W:13.5KG
G.W:15KG
MEAS:48X27X19CM
0.16 0.04 0.1-0.16 1.9 CQV2-ME01
0.25 0.07 0.16-0.25 3 CQV2-ME02
0.4 0.09/0.12 0.25-0.4 4.8 CQV2-ME03
0.63 0.12/0.18 0.4-0.63 7.2 CQV2-ME04
1 0.25 0.63-1 12 CQV2-ME05
1.6 0.37/0.55 1-1.6 19 CQV2-ME06
2.5 0.75 1.6-2.5 30 CQV2-ME07
4 1.1/1.5 2.5-4 51 CQV2-ME08
6.3 2.2 4-6.3 78 CQV2-ME10
10 3/4 6-10 138 CQV2-ME14
14 4/6.5 9-14 170 CQV2-ME16
18 7/8 13-18 220 CQV2-ME20
23 8/10 17-23 320 CQV2-ME21
25 9/12 20-25 350 CQV2-ME22
32 15 24-32 420 CQV2-ME32
CQV2-ME80 40 18.5 25-40 480 CQV2-ME40 QTY:30PCS
N.W:23KG
G.W:23.5KG
MEAS:42X36X27.7CM
63 28 40-63 720 CQV2-ME63
80 32 56-80 960 CQV2-ME80

Descripción de accesorios

CQV-AE: Instantaneous Auxiliary Contact.

CQV-AN/AD/AM: Combination of Signal Contacts for trouble and short-circuit signals.

Modelo de producto Accessory Name Part Code Contact Configuration Mounting Position
CQV-AE Instantaneous Auxiliary Contact AE1 1NO or 1NC Front
CQV-AE Instantaneous Auxiliary Contact AE11 1NO or 1NC Front
CQV-AE Instantaneous Auxiliary Contact AE20 2NO Front
CQV-AN (-AD-AM) Trouble Signal Contact AD1001 1NC (Fault) Left
CQV-AN (-AD-AM) Trouble Signal Contact AD1010 1NO (Fault) Left
CQV-AN (-AD-AM) Instantaneous Auxiliary Contact AM11 1NO + 1NC Left

CQV-AU/AX/AS: Under-voltage Disjoining Accessory.

Modelo de producto Release Type Part Code Voltaje Operating Range
CQV2-AU (-AX-AS) Undervoltage Release AU225 220-240V AC Operate: 0.85-1.1Ue;
Trip: 0.35-0.7Ue
CQV2-AU (-AX-AS) Undervoltage Release AU385 380-415V AC Operate: 0.85-1.1Ue;
Trip: 0.35-0.7Ue
CQV2-AU (-AX-AS) Shunt Release AS115 220-240V AC Operate: 0.85-1.1Ue;
Trip: 0.2-0.75Ue
CQV2-AU (-AX-AS) Shunt Release AS225 220-240V AC Operate: 0.85-1.1Ue;
Trip: 0.2-0.75Ue
CQV2-AU (-AX-AS) Shunt Release AS385 220-240V AC Operate: 0.85-1.1Ue;
Trip: 0.2-0.75Ue

CQV2-MC02: Circuit Shield

Modelo de producto Solicitud Protection Type Protection Rating Packing Dimensions (cm)
CQV2-MC02 For CQV2 breakers with/without accessories (max 1/side) Surface-mount. double-insulated, sealed cover IP55 51×31.5×48.5

¿Por qué elegir CHAC?

Con más de 30 años de experiencia en fabricación, más de 1100 empleados, más de 100 millones de postes
Con una capacidad anual y un proceso de producción automatizado 90%, CHAC ofrece una capacidad de producción estable y un estricto
control de calidad para clientes OEM/ODM globales. Nuestro sistema de fabricación interno respalda a largo plazo
Cooperación para marcas eléctricas, importadores y distribuidores.


30+

AÑOS DE EXPERIENCIA

Especializado en fabricación eléctrica de bajo voltaje


1100+

EMPLEADOS

Equipo profesional garantiza calidad y entrega estables


100M+

CAPACIDAD ANUAL DE LOS POLOS

Capacidad de producción a gran escala para satisfacer la demanda mundial


90%

PRODUCCIÓN AUTOMATIZADA

Automatización avanzada para alta eficiencia y consistencia

Línea de ensamblaje automatizada

Línea de ensamblaje automatizada

Laboratorio de pruebas

Laboratorio de pruebas

Inyección y Estampado

Inyección y Estampado

Inspección de calidad

Inspección de calidad

Certificación IEC
Certificación CE
Certificación CB
Certificación RoHS
Certificación ISO 14001

Un estricto sistema de control de calidad garantiza que cada producto cumpla con los estándares mundiales.

¿Qué podemos personalizar?

CHAC admite la personalización del voltaje de la bobina y la configuración de los contactos auxiliares.,
parámetros eléctricos, marca del producto, diseño de envasado y desarrollo de ingeniería según los equipos y requisitos de mercado de los clientes.

Voltaje de la bobina

Voltaje de la bobina

Opciones de voltaje de bobina de CA y CC adaptadas a los requisitos de la aplicación.

Personalización del voltaje de la bobina para opciones de voltaje de bobina de CA y CC
Contactos Auxiliares

Contactos Auxiliares

Combinaciones flexibles de contactos auxiliares para diferentes funciones de control.

Personalización de contactos auxiliares para diferentes funciones de control
Parámetros eléctricos

Parámetros eléctricos

Las clasificaciones actuales, los rangos de protección y los parámetros funcionales se pueden personalizar.

Personalización de parámetros eléctricos para rangos de corriente y protección
Marca de producto

Marca de producto

Logotipos de marca privada, placas de identificación y soporte para la identificación de productos.

Personalización de marca de producto que incluye logotipos de marca privada y placas de identificación
Diseño de empaque

Diseño de empaque

Soluciones de embalaje, cajas personalizadas, etiquetas y manuales.

Diseño de empaque personalizable, incluyendo cajas, etiquetas, manuales y soluciones de empaque.
Desarrollo de Ingeniería

Desarrollo de Ingeniería

Soporte desde la optimización de dibujos hasta el desarrollo de productos y la adaptación de aplicaciones.

Soporte de desarrollo de ingeniería desde la optimización de dibujos hasta el desarrollo de productos

Descargar

PDF

Protector de motor serie CQV2

Descripción general completa de componentes eléctricos de bajo voltaje y referencia para la selección de productos.

Descargar PDF

Arriba

¿Necesita documentos técnicos?

Contáctenos para obtener hojas de datos, certificados, planos, orientación de selección o soporte para proyectos OEM/ODM.

Contáctanos

CQV2 Product FAQ

What protection does the CQV2 provide?

The product record describes overload, phase-failure and short-circuit protection for compatible AC motor circuits. Confirm the exact setting range and motor data.

How is the current setting selected?

Set the protector from the motor nameplate and measured operating conditions, then verify starting current, ambient temperature and conductor coordination.

Can it be used as an isolator?

The current record identifies an isolation function, but the installation must still meet the required isolation, enclosure and local-code conditions.

Which motors are suitable?

The published application is three-phase squirrel-cage asynchronous motors. Confirm motor power, voltage, duty and starting method.

What accessories can be added?

Auxiliary, signal or under-voltage accessories depend on the CQV2 variant. Check the exact accessory code and wiring diagram.

How should nuisance trips be investigated?

Record motor current, phase balance, start time, ambient temperature and terminal condition before changing the setting.

Confirm the Right CQV2 Configuration

Send the exact model, operating conditions, quantity, destination market and required documents. CHAC will review the request against the published product data.

Solicitar un presupuesto