Interruptor Automático de Protección de Motores Serie CQV2
El Interruptor Automático de Protección de Motores Serie CQV2 is a CHAC motor protection circuit breaker for overload, phase-failure and short-circuit protection. The page keeps the model-specific technical table and original product images so buyers can verify voltage, current, configuration, mounting and applicable standards before ordering. Final suitability depends on the complete circuit, installation method and destination-market rules.
Descripción del producto
CQV2 Series Motor Protection Circuit Breaker is a motor protection circuit breaker intended for overload, phase-failure and short-circuit protection. The current product record identifies it for three-phase motors, pumps and machine feeders. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.
Verified source summary: Type Designation Tripping Characteristic Curve Test condition: Ambient temperature 20℃ Curve parameters (based on multiples of setting current in): (1) Starting from cold state, 3-pole (2) Starting from cold state, 2-pole (3) Starting from hot state, 3-pole Dimensions (mm) CQV2-ME CQV-AU/AX/AS CQV-AN/AD/AM CQV-AE Circuit Shield Technical Specifications Product Model Rated current(A) Motor output(kW) Setting Range(A)
Características clave
Aplicaciones típicas
Typical use can include three-phase motors, pumps and machine feeders when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.
Guía de Solicitudes y Selección
Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.
| Punto de selección | Interruptor Automático de Protección de Motores Serie CQV2 | Lo que el proyecto debe confirmar |
|---|---|---|
| Solicitud | Motor Protector projects | Confirm the actual system and environment |
| Selection basis | overload, phase-failure and short-circuit protection | Use the exact model and technical table |
| Instalación | Follow the model instructions | Check mounting, clearances and termination |
| Cumplimiento | Use the listed standard where applicable | Verify edition, scope and destination rules |
| Adjacent product | Evaluate the related CHAC family where function differs | Do not substitute without engineering review |
Function
overload, phase-failure and short-circuit protection
Match the protection or switching function to the system.
Configuración
Model-specific options
Confirm current, voltage, poles, terminals or accessories from the table.
Instalación
Mechanical and electrical fit
Check enclosure, mounting, wiring space and maintenance access.
Project evidence
Documents and test records
Retain the approved drawing, technical sheet and commissioning record.
Guía de pedidos
- State the exact model and variant.
- Provide the system voltage, current, frequency and load or protection function.
- Confirm mounting, terminals, accessories, enclosure and environmental conditions.
- Share quantity, destination market and required technical documents.
Comprobaciones de Instalación y Coordinación
- Verify the model’s ratings and connection arrangement against the project drawings.
- Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
- Coordinate upstream and downstream protection or control devices where applicable.
- Use qualified personnel for installation, testing, isolation and maintenance.
Type Designation

Tripping Characteristic Curve

Test condition: Ambient temperature 20℃
Curve parameters (based on multiples of setting current in):
(1) Starting from cold state, 3-pole
(2) Starting from cold state, 2-pole
(3) Starting from hot state, 3-pole
Dimensiones (mm)
CQV2-ME

CQV-AU/AX/AS CQV-AN/AD/AM CQV-AE

Circuit Shield

Especificaciones técnicas
| Modelo de producto | Rated current(A) | Motor output(kW) | Setting Range(A) | Order Number | Packing parameters | |
| CQV2-ME32 | Thermal overload releases
|
Instantaneous overcurrent releases
|
QTY:50PCS N.W:13.5KG G.W:15KG MEAS:48X27X19CM |
|||
| 0.16 | 0.04 | 0.1-0.16 | 1.9 | CQV2-ME01 | ||
| 0.25 | 0.07 | 0.16-0.25 | 3 | CQV2-ME02 | ||
| 0.4 | 0.09/0.12 | 0.25-0.4 | 4.8 | CQV2-ME03 | ||
| 0.63 | 0.12/0.18 | 0.4-0.63 | 7.2 | CQV2-ME04 | ||
| 1 | 0.25 | 0.63-1 | 12 | CQV2-ME05 | ||
| 1.6 | 0.37/0.55 | 1-1.6 | 19 | CQV2-ME06 | ||
| 2.5 | 0.75 | 1.6-2.5 | 30 | CQV2-ME07 | ||
| 4 | 1.1/1.5 | 2.5-4 | 51 | CQV2-ME08 | ||
| 6.3 | 2.2 | 4-6.3 | 78 | CQV2-ME10 | ||
| 10 | 3/4 | 6-10 | 138 | CQV2-ME14 | ||
| 14 | 4/6.5 | 9-14 | 170 | CQV2-ME16 | ||
| 18 | 7/8 | 13-18 | 220 | CQV2-ME20 | ||
| 23 | 8/10 | 17-23 | 320 | CQV2-ME21 | ||
| 25 | 9/12 | 20-25 | 350 | CQV2-ME22 | ||
| 32 | 15 | 24-32 | 420 | CQV2-ME32 | ||
| CQV2-ME80 | 40 | 18.5 | 25-40 | 480 | CQV2-ME40 | QTY:30PCS N.W:23KG G.W:23.5KG MEAS:42X36X27.7CM |
| 63 | 28 | 40-63 | 720 | CQV2-ME63 | ||
| 80 | 32 | 56-80 | 960 | CQV2-ME80 | ||
Descripción de accesorios
CQV-AE: Instantaneous Auxiliary Contact.
CQV-AN/AD/AM: Combination of Signal Contacts for trouble and short-circuit signals.
| Modelo de producto | Accessory Name | Part Code | Contact Configuration | Mounting Position |
| CQV-AE | Instantaneous Auxiliary Contact | AE1 | 1NO or 1NC | Front |
| CQV-AE | Instantaneous Auxiliary Contact | AE11 | 1NO or 1NC | Front |
| CQV-AE | Instantaneous Auxiliary Contact | AE20 | 2NO | Front |
| CQV-AN (-AD-AM) | Trouble Signal Contact | AD1001 | 1NC (Fault) | Left |
| CQV-AN (-AD-AM) | Trouble Signal Contact | AD1010 | 1NO (Fault) | Left |
| CQV-AN (-AD-AM) | Instantaneous Auxiliary Contact | AM11 | 1NO + 1NC | Left |
CQV-AU/AX/AS: Under-voltage Disjoining Accessory.
| Modelo de producto | Release Type | Part Code | Voltaje | Operating Range |
| CQV2-AU (-AX-AS) | Undervoltage Release | AU225 | 220-240V AC | Operate: 0.85-1.1Ue; Trip: 0.35-0.7Ue |
| CQV2-AU (-AX-AS) | Undervoltage Release | AU385 | 380-415V AC | Operate: 0.85-1.1Ue; Trip: 0.35-0.7Ue |
| CQV2-AU (-AX-AS) | Shunt Release | AS115 | 220-240V AC | Operate: 0.85-1.1Ue; Trip: 0.2-0.75Ue |
| CQV2-AU (-AX-AS) | Shunt Release | AS225 | 220-240V AC | Operate: 0.85-1.1Ue; Trip: 0.2-0.75Ue |
| CQV2-AU (-AX-AS) | Shunt Release | AS385 | 220-240V AC | Operate: 0.85-1.1Ue; Trip: 0.2-0.75Ue |
CQV2-MC02: Circuit Shield
| Modelo de producto | Solicitud | Protection Type | Protection Rating | Packing Dimensions (cm) |
| CQV2-MC02 | For CQV2 breakers with/without accessories (max 1/side) | Surface-mount. double-insulated, sealed cover | IP55 | 51×31.5×48.5 |
¿Por qué elegir CHAC?
Con más de 30 años de experiencia en fabricación, más de 1100 empleados, más de 100 millones de postes
Con una capacidad anual y un proceso de producción automatizado 90%, CHAC ofrece una capacidad de producción estable y un estricto
control de calidad para clientes OEM/ODM globales. Nuestro sistema de fabricación interno respalda a largo plazo
Cooperación para marcas eléctricas, importadores y distribuidores.
30+
AÑOS DE EXPERIENCIA
Especializado en fabricación eléctrica de bajo voltaje
1100+
EMPLEADOS
Equipo profesional garantiza calidad y entrega estables
100M+
CAPACIDAD ANUAL DE LOS POLOS
Capacidad de producción a gran escala para satisfacer la demanda mundial
90%
PRODUCCIÓN AUTOMATIZADA
Automatización avanzada para alta eficiencia y consistencia

Línea de ensamblaje automatizada

Laboratorio de pruebas

Inyección y Estampado

Inspección de calidad





Un estricto sistema de control de calidad garantiza que cada producto cumpla con los estándares mundiales.
¿Qué podemos personalizar?
CHAC admite la personalización del voltaje de la bobina y la configuración de los contactos auxiliares.,
parámetros eléctricos, marca del producto, diseño de envasado y desarrollo de ingeniería según los equipos y requisitos de mercado de los clientes.
Voltaje de la bobina
Opciones de voltaje de bobina de CA y CC adaptadas a los requisitos de la aplicación.

Contactos Auxiliares
Combinaciones flexibles de contactos auxiliares para diferentes funciones de control.

Parámetros eléctricos
Las clasificaciones actuales, los rangos de protección y los parámetros funcionales se pueden personalizar.

Marca de producto
Logotipos de marca privada, placas de identificación y soporte para la identificación de productos.

Diseño de empaque
Soluciones de embalaje, cajas personalizadas, etiquetas y manuales.

Desarrollo de Ingeniería
Soporte desde la optimización de dibujos hasta el desarrollo de productos y la adaptación de aplicaciones.

Descargar
Protector de motor serie CQV2
Descripción general completa de componentes eléctricos de bajo voltaje y referencia para la selección de productos.
¿Necesita documentos técnicos?
Contáctenos para obtener hojas de datos, certificados, planos, orientación de selección o soporte para proyectos OEM/ODM.
CQV2 Product FAQ
What protection does the CQV2 provide?
The product record describes overload, phase-failure and short-circuit protection for compatible AC motor circuits. Confirm the exact setting range and motor data.
How is the current setting selected?
Set the protector from the motor nameplate and measured operating conditions, then verify starting current, ambient temperature and conductor coordination.
Can it be used as an isolator?
The current record identifies an isolation function, but the installation must still meet the required isolation, enclosure and local-code conditions.
Which motors are suitable?
The published application is three-phase squirrel-cage asynchronous motors. Confirm motor power, voltage, duty and starting method.
What accessories can be added?
Auxiliary, signal or under-voltage accessories depend on the CQV2 variant. Check the exact accessory code and wiring diagram.
How should nuisance trips be investigated?
Record motor current, phase balance, start time, ambient temperature and terminal condition before changing the setting.
Confirm the Right CQV2 Configuration
Send the exact model, operating conditions, quantity, destination market and required documents. CHAC will review the request against the published product data.