Disjuntor de Proteção de Motor da Série CQV2
O Disjuntor de Proteção de Motor da Série CQV2 is a CHAC motor protection circuit breaker for overload, phase-failure and short-circuit protection. The page keeps the model-specific technical table and original product images so buyers can verify voltage, current, configuration, mounting and applicable standards before ordering. Final suitability depends on the complete circuit, installation method and destination-market rules.
Visão Geral do Produto
CQV2 Series Motor Protection Circuit Breaker is a motor protection circuit breaker intended for overload, phase-failure and short-circuit protection. The current product record identifies it for three-phase motors, pumps and machine feeders. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.
Verified source summary: Type Designation Tripping Characteristic Curve Test condition: Ambient temperature 20℃ Curve parameters (based on multiples of setting current in): (1) Starting from cold state, 3-pole (2) Starting from cold state, 2-pole (3) Starting from hot state, 3-pole Dimensions (mm) CQV2-ME CQV-AU/AX/AS CQV-AN/AD/AM CQV-AE Circuit Shield Technical Specifications Product Model Rated current(A) Motor output(kW) Setting Range(A)
Principais Características
Aplicações Típicas
Typical use can include three-phase motors, pumps and machine feeders when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.
Guia de Candidaturas e Seleção
Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.
| Ponto de seleção | Disjuntor de Proteção de Motor da Série CQV2 | O que o projeto deve confirmar |
|---|---|---|
| Aplicação | Motor Protector projects | Confirm the actual system and environment |
| Selection basis | overload, phase-failure and short-circuit protection | Use the exact model and technical table |
| Instalação | Follow the model instructions | Check mounting, clearances and termination |
| Compliance | Use the listed standard where applicable | Verify edition, scope and destination rules |
| Adjacent product | Evaluate the related CHAC family where function differs | Do not substitute without engineering review |
Function
overload, phase-failure and short-circuit protection
Match the protection or switching function to the system.
Configuração
Model-specific options
Confirm current, voltage, poles, terminals or accessories from the table.
Instalação
Mechanical and electrical fit
Check enclosure, mounting, wiring space and maintenance access.
Project evidence
Documents and test records
Retain the approved drawing, technical sheet and commissioning record.
Guia de Encomenda
- State the exact model and variant.
- Provide the system voltage, current, frequency and load or protection function.
- Confirm mounting, terminals, accessories, enclosure and environmental conditions.
- Share quantity, destination market and required technical documents.
Verificações de Instalação e Coordenação
- Verify the model’s ratings and connection arrangement against the project drawings.
- Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
- Coordinate upstream and downstream protection or control devices where applicable.
- Use qualified personnel for installation, testing, isolation and maintenance.
Type Designation

Tripping Characteristic Curve

Test condition: Ambient temperature 20℃
Curve parameters (based on multiples of setting current in):
(1) Starting from cold state, 3-pole
(2) Starting from cold state, 2-pole
(3) Starting from hot state, 3-pole
Dimensões (mm)
CQV2-ME

CQV-AU/AX/AS CQV-AN/AD/AM CQV-AE

Circuit Shield

Especificações Técnicas
| Modelo de produto | Rated current(A) | Motor output(kW) | Setting Range(A) | Order Number | Packing parameters | |
| CQV2-ME32 | Thermal overload releases
|
Instantaneous overcurrent releases
|
QTY:50PCS N.W:13.5KG G.W:15KG MEAS:48X27X19CM |
|||
| 0.16 | 0.04 | 0.1-0.16 | 1.9 | CQV2-ME01 | ||
| 0.25 | 0.07 | 0.16-0.25 | 3 | CQV2-ME02 | ||
| 0.4 | 0.09/0.12 | 0.25-0.4 | 4.8 | CQV2-ME03 | ||
| 0.63 | 0.12/0.18 | 0.4-0.63 | 7.2 | CQV2-ME04 | ||
| 1 | 0.25 | 0.63-1 | 12 | CQV2-ME05 | ||
| 1.6 | 0.37/0.55 | 1-1.6 | 19 | CQV2-ME06 | ||
| 2.5 | 0.75 | 1.6-2.5 | 30 | CQV2-ME07 | ||
| 4 | 1.1/1.5 | 2.5-4 | 51 | CQV2-ME08 | ||
| 6.3 | 2.2 | 4-6.3 | 78 | CQV2-ME10 | ||
| 10 | 3/4 | 6-10 | 138 | CQV2-ME14 | ||
| 14 | 4/6.5 | 9-14 | 170 | CQV2-ME16 | ||
| 18 | 7/8 | 13-18 | 220 | CQV2-ME20 | ||
| 23 | 8/10 | 17-23 | 320 | CQV2-ME21 | ||
| 25 | 9/12 | 20-25 | 350 | CQV2-ME22 | ||
| 32 | 15 | 24-32 | 420 | CQV2-ME32 | ||
| CQV2-ME80 | 40 | 18.5 | 25-40 | 480 | CQV2-ME40 | QTY:30PCS N.W:23KG G.W:23.5KG MEAS:42X36X27.7CM |
| 63 | 28 | 40-63 | 720 | CQV2-ME63 | ||
| 80 | 32 | 56-80 | 960 | CQV2-ME80 | ||
Descrição dos Acessórios
CQV-AE: Instantaneous Auxiliary Contact.
CQV-AN/AD/AM: Combination of Signal Contacts for trouble and short-circuit signals.
| Modelo de produto | Accessory Name | Part Code | Contact Configuration | Mounting Position |
| CQV-AE | Instantaneous Auxiliary Contact | AE1 | 1NO or 1NC | Front |
| CQV-AE | Instantaneous Auxiliary Contact | AE11 | 1NO or 1NC | Front |
| CQV-AE | Instantaneous Auxiliary Contact | AE20 | 2NO | Front |
| CQV-AN (-AD-AM) | Trouble Signal Contact | AD1001 | 1NC (Fault) | Left |
| CQV-AN (-AD-AM) | Trouble Signal Contact | AD1010 | 1NO (Fault) | Left |
| CQV-AN (-AD-AM) | Instantaneous Auxiliary Contact | AM11 | 1NO + 1NC | Left |
CQV-AU/AX/AS: Under-voltage Disjoining Accessory.
| Modelo de produto | Release Type | Part Code | Tensão | Operating Range |
| CQV2-AU (-AX-AS) | Undervoltage Release | AU225 | 220-240V AC | Operate: 0.85-1.1Ue; Trip: 0.35-0.7Ue |
| CQV2-AU (-AX-AS) | Undervoltage Release | AU385 | 380-415V AC | Operate: 0.85-1.1Ue; Trip: 0.35-0.7Ue |
| CQV2-AU (-AX-AS) | Shunt Release | AS115 | 220-240V AC | Operate: 0.85-1.1Ue; Trip: 0.2-0.75Ue |
| CQV2-AU (-AX-AS) | Shunt Release | AS225 | 220-240V AC | Operate: 0.85-1.1Ue; Trip: 0.2-0.75Ue |
| CQV2-AU (-AX-AS) | Shunt Release | AS385 | 220-240V AC | Operate: 0.85-1.1Ue; Trip: 0.2-0.75Ue |
CQV2-MC02: Circuit Shield
| Modelo de produto | Aplicação | Protection Type | Protection Rating | Packing Dimensions (cm) |
| CQV2-MC02 | For CQV2 breakers with/without accessories (max 1/side) | Surface-mount. double-insulated, sealed cover | IP55 | 51×31.5×48.5 |
Porquê escolher a CHAC
Com mais de 30 anos de experiência em fabrico, mais de 1100 funcionários, mais de 100 milhões de postes
Com uma capacidade anual e um processo de produção automatizado 90%, a CHAC garante uma capacidade de produção estável e rigorosos
Controlo de qualidade para clientes OEM/ODM globais. O nosso sistema de fabrico interno suporta a longo prazo
cooperação para marcas elétricas, importadores e distribuidores.
30+
ANOS DE EXPERIÊNCIA
Especializado em fabrico de baixa tensão elétrica
1100+
FUNCIONÁRIOS
Equipa profissional garante qualidade e entrega estáveis
100M+
CAPACIDADE ANUAL DE POSTOS
Capacidade de produção em larga escala para satisfazer a procura global
90%
PRODUÇÃO AUTOMATIZADA
Automação avançada para alta eficiência e consistência

Linha de Montagem Automatizada

Laboratório de Ensaios

Injeção e Estampagem

Inspeção de Qualidade





Um rigoroso sistema de controlo de qualidade garante que cada produto cumpre as normas globais.
O que podemos personalizar?
A CHAC suporta a personalização da tensão da bobina e da configuração dos contactos auxiliares,
parâmetros elétricos, branding do produto, design de embalagem e desenvolvimento de engenharia de acordo com os equipamentos dos clientes e os requisitos do mercado.
Tensão da bobina
Opções de tensão de bobina AC e DC adaptadas aos requisitos da aplicação.

Contactos Auxiliares
Combinações flexíveis de contactos auxiliares para diferentes funções de controlo.

Parâmetros Elétricos
As classificações atuais, os intervalos de proteção e os parâmetros funcionais podem ser personalizados.

Branding de Produto
Logótipos de marca própria, placas de identificação e suporte para identificação de produtos.

Design de Embalagem
Caixas personalizadas, etiquetas, manuais e soluções de embalagem.

Desenvolvimento de engenharia
Suporte desde a otimização de desenhos ao desenvolvimento de produtos e à compatibilidade de aplicações.

Transferir
Protetor de Motor Série CQV2
Visão geral completa de componentes elétricos de baixa tensão e referência para seleção de produtos.
Precisa de Documentos Técnicos?
Contacte-nos para folhas de dados, certificados, desenhos, orientação de seleção ou suporte a projetos OEM/ODM.
CQV2 Product FAQ
What protection does the CQV2 provide?
The product record describes overload, phase-failure and short-circuit protection for compatible AC motor circuits. Confirm the exact setting range and motor data.
How is the current setting selected?
Set the protector from the motor nameplate and measured operating conditions, then verify starting current, ambient temperature and conductor coordination.
Can it be used as an isolator?
The current record identifies an isolation function, but the installation must still meet the required isolation, enclosure and local-code conditions.
Which motors are suitable?
The published application is three-phase squirrel-cage asynchronous motors. Confirm motor power, voltage, duty and starting method.
What accessories can be added?
Auxiliary, signal or under-voltage accessories depend on the CQV2 variant. Check the exact accessory code and wiring diagram.
How should nuisance trips be investigated?
Record motor current, phase balance, start time, ambient temperature and terminal condition before changing the setting.
Confirm the Right CQV2 Configuration
Send the exact model, operating conditions, quantity, destination market and required documents. CHAC will review the request against the published product data.