CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker

Le CQB7R-125 is specified for overload and short-circuit protection with prepaid-meter control functions. Select it using the published voltage, current, pole and protection data, then confirm conductor coordination, fault conditions, enclosure requirements and local installation rules.

Poles :
2P / 4P
Courant nominal :
40–125A
Tension nominale :
30/400V AC by pole arrangement
Fonction principale :
overload and short-circuit protection with prepaid-meter control functions
Données de sélection :
B/C/D curves and automatic trip/close timing from the technical table
Standard
IEC 60898-1 references

Vue d'ensemble du produit

CQB7R-125 is a prepaid meter circuit breaker for 30/400V AC by pole arrangement applications. It is intended for prepaid-meter panels where the utility or project control scheme supports the function; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.

overload and short-circuit protection with prepaid-meter control functions is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.

Principales caractéristiques

  • Published pole options: 2P / 4P.
  • Published electrical context: 30/400V AC by pole arrangement.
  • Primary function: overload and short-circuit protection with prepaid-meter control functions.
  • Selection reference: B/C/D curves and automatic trip/close timing from the technical table.
  • Applicable standard reference: IEC 60898-1 references.
  • Final selection must use the exact model table, drawings and installation instructions.

Applications typiques

prepaid-meter panels where the utility or project control scheme supports the function. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.

Demandes d’admission et guide de sélection

Use the verified CQB7R-125 records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.

Point de sélection CQB7R-125 reference Ce que le projet doit confirmer
Rated current Use the exact model table Design current, conductor capacity, ambient and grouping
Voltage and frequency 30/400V AC by pole arrangement Supply system and equipment rating
Pôles 2P / 4P Conductors to be switched, protected or isolated
Protection / control overload and short-circuit protection with prepaid-meter control functions Required function and adjacent-device coordination
Fault / residual data B/C/D curves and automatic trip/close timing from the technical table Prospective short-circuit or leakage conditions

Local Protection and Smart Control

Remote monitoring or automatic control does not replace local protection, isolation and commissioning procedures. Verify network, control and fallback behaviour.

Control Architecture
Request Technical Support →

Model-Specific Ratings

Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.

Verified Data
View Technical Support →

Installation and Coordination

Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.

Engineering Check
Discuss a Configuration →

Ordering Information

State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.

Project Inputs
Send Project Details →

Guide d'achat

  1. State the exact model: CQB7R-125.
  2. Provide rated current and voltage from the published technical table.
  3. Confirm poles and the required protection, isolation or control function.
  4. Provide application, expected fault/leakage conditions, destination market and quantity.
  5. List accessory, terminal, documentation and approved marking or packaging requirements.

Installation and Coordination Checks

  • Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
  • Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
  • Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
  • Installation, testing and maintenance must be completed by qualified personnel under applicable rules.

Type designation

Cqb7R 125 Series Prepaid Energy Meter External Circuit Breaker product image

Tripping curves

Cqb7R 125 Series Prepaid Energy Meter External Circuit Breaker product image

Dimensions(mm)

Cqb7R 125 Series Prepaid Energy Meter External Circuit Breaker product image

Technical Specifications

Parameter
Rated voltage (V) 30V~(2P), 400V~(4P)
Rated current (A) 40,50,63,80,100,125
Rated impulse withstand voltage Uimp(V) 6000V
Rated frequency 50Hz/60Hz
Polar number 2P,4P
Rated short-circuit capacity lcn(A) 6kA, 10kA(high breaking score)
Operating short-circuit capacity Ics(A) 6kA,7.5kA (high break type)
Mechanical and electrical life (times) Mechanical life ≥ 10,000, electrical life ≥ 6,000
Instantaneous tripping type B,C,D
Tightening torque (N.m) 3.5
Automatic closing time (tc) t ≤ 3s
Automatic opening time (td) t ≤ 2s
Pollution level Level 2
Protection grade IP20
Installation category Ⅲ
Meet the standards IEC60898-1, GB10963-1
Certification CCC

Tripping characteristics (Reference temperature 30℃)

Item Tripping Curve Test current In(A) Initial Status Time limit for tripping or non-tripping Expected result Remarks
a B, C, D 1.13In Cold t ≤ 1h Non-tripping Current smoothly rises to specified value within 5s
b B, C, D 1.45In Following item a test t < 1h Tripping
c B, C, D 2.55In Cold 1s < t < 60s (In ≤ 32A)
1s < t < 120s (In > 32A)
Tripping
d B 3In Cold t ≤ 0.1s Non-tripping Switch on the power supply by closing the auxiliary switch
C 5In
D 10In
e B 5In Cold t < 0.1s Tripping Switch on the power supply by closing the auxiliary switch
C 10In
D 20In

Note: The term “cold” means that the test is carried out at a refererce calibration temperature without load before the test

Conductor requirements and cross section

Copper cross-section(mm2) Rated current In(A)
10 32<In≤50
16 50<In≤63
25 63<In≤80
35 80<In≤100
50 100<In≤125

Pourquoi choisir CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.

Cqw2 Series Air Circuit Breaker product image
30+

ANNÉE D'EXPÉRIENCE

Spécialisée dans la fabrication d'appareils électriques à faible tension

Cqw2 Series Air Circuit Breaker product image
1100+

EMPLOYÉS

Une équipe professionnelle garantit une qualité et une livraison stables

Cqw2 Series Air Circuit Breaker product image
100 millions d'euros

Capacité annuelle des poteaux

Capacité de production à grande échelle pour répondre à la demande mondiale

Cqw2 Series Air Circuit Breaker product image
90%

PRODUCTION AUTOMATIQUE

Une automatisation avancée pour une efficacité et une cohérence élevées

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image

Ligne de montage automatisée

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image

Laboratoire d'essai

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image

Injection et estampage

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image

Inspection de qualité

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image
CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image
CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image
CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image
CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image

Strict quality control system ensures every product meets global standards.

Qu'est-ce que nous pouvons personnaliser ?

For CQB7R-125 projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.

Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Logo et identité visuelle

Solutions d'impression de logos personnalisés, marquage laser et plaques d'identification.

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Emballage
Personnalisation

Boîtes, cartons, étiquettes et manuels de couleurs personnalisés.

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Électrique
Personnalisation

Current, voltage, breaking capacity, trip curve and other
special functions.

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Produit
Apparence

Personnalisation de la couleur de l’habillage, de la poignée et de l’apparence.

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Certification
Support

Products comply with international standards and market
requirements.

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker product image

Ingénierie
Développement

Évaluation des dessins, test des prototypes et production en série.

CQB7R-125 Series Prepaid Energy Meter External Circuit Breaker product image

Télécharger

PDF

Disjoncteur miniature de la série PXB9

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Contactez-nous

CQB7R-125 Product FAQ

What is the CQB7R-125 used for?

The CQB7R-125 is specified for overload and short-circuit protection with prepaid-meter control functions in 30/400V AC by pole arrangement applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.

How does the CQB7R-125 support prepaid-meter control?

The page lists external prepaid-meter use with automatic tripping and closing. Confirm the meter interface, control sequence, timing and utility or project requirements before installation.

How do I choose the CQB7R-125 rating and poles?

Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 2P / 4P; confirm neutral, polarity, conductors and isolation requirements.

What safety limitation applies to the CQB7R-125?

Do not treat the CQB7R-125 as a universal substitute for another device. Confirm B/C/D curves and automatic trip/close timing from the technical table, the system voltage, fault or leakage conditions and any separate upstream protection before selection.

Can the CQB7R-125 be used in another circuit type?

Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.

How should the CQB7R-125 be installed and tested?

Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.

Confirm the Right CQB7R-125 Configuration

Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.

Demander un devis