PXB6-63 Pemutus Sirkuit Miniatur

Itu PXB6-63 miniature circuit breaker provides overload and short-circuit protection within the published 6A–63A range. Its verified product data lists 6kA Icu = Ics, 1P / 2P / 3P / 4P and B / C / D. Final selection must match the conductor, load, prospective fault current, installation system and applicable local rules.

Polandia:
1P / 2P / 3P / 4P
Nilai arus:
6A–63A
Rating Listrik:
Voltan isolasi bertegangan 500 V (Ui)
Frekvens:
50/60Hz
Pengecekan Data:
6kA Icu = Ics
Jenis Perjalanan / Residual:
B / C / D
Standar:
IEC 60898-1; GB/T 10963.1
Pemasangan:
Referensi terminal-pusat 45 mm

Gambaran Produk

PXB6-63 is a 6kA Icu = Ics miniature circuit breaker covering 6A–63A. It is available with 1P / 2P / 3P / 4P and B / C / D trip options as stated in the product data. It provides overload and short-circuit protection and positive isolation.

The updated model data references IEC 60898-1; GB/T 10963.1 and lists CE, CB and CCC certification, together with DEKRA certification. Standards, certification scope and technical documents must be confirmed for the ordered configuration and destination market.

Fitur Utama

  • High interruption rating capability.
  • Overload and short-circuit protection.
  • Positive isolation.
  • Suitable for circuit protection in industrial, commercial and high-rise buildings and residential properties.
  • Published current range: 6A–63A.
  • Pole configuration: 1P / 2P / 3P / 4P.
  • Trip / protection option: B / C / D.
  • Short-circuit data: 6kA Icu = Ics.
  • Electrical reference: 500V rated insulation voltage (Ui), 50/60Hz.
  • Endurance data: 20,000 mechanical and 10,000 electrical operations.
  • Additional verified data: 4kV Uimp; IP20; conductor reference up to 16mm².

Aplikasi Biasa

It is intended for AC distribution circuits where the selected current rating, curve, pole arrangement and breaking capacity match the conductor and system study. Typical project contexts include residential, commercial, high-rise and industrial final distribution; suitability depends on the actual circuit rather than the application label alone.

Permohonan dan Panduan Pemilihan

Use the product-specific values below as a shortlist, then validate the complete circuit design. Product ratings do not replace a fault-current study, conductor calculation, coordination review or applicable installation rules.

Titik pemilihan PXB6-63 option Hal yang harus dipastikan oleh proyek tersebut
Rated current 6A–63A Coordinate with design current, conductor ampacity, ambient temperature and grouping
Trip curve B / C / D Choose for load inrush and required fault-clearing performance, not by current alone
Kapasitas pemecahan 6kA Icu = Ics Confirm against the prospective short-circuit current at the installation point
Susunan tiang 1P / 2P / 3P / 4P Match supply system and local switching or isolation rules
Installation interface Referensi terminal-pusat 45 mm Check enclosure, rail/base, terminal and conductor compatibility

Breaking Capacity

6kA Icu = Ics is the published product value. Confirm the prospective short-circuit current at the installation point.

Fault LevelPemilihan Proyek

Trip and Load Behaviour

B / C / D is the available trip/protection option. Match it to load inrush and required disconnection performance.

Load InrushPemilihan Proyek

Pole Configuration

Available arrangement: 1P / 2P / 3P / 4P. Confirm which conductors must be switched and protected under local rules.

Circuit LayoutPemilihan Proyek

MCB or RCBO

An MCB does not replace residual-current protection where an RCD or RCBO is required.

Protection ScopePemilihan Proyek

Panduan Pemesanan

  1. Specify the exact model: PXB6-63.
  2. State the required current rating within 6A–63A.
  3. Confirm pole arrangement: 1P / 2P / 3P / 4P.
  4. Confirm trip or protection option: B / C / D.
  5. Provide system voltage, expected fault level, destination market, quantity and any document requirements.

Ordering Specification

Please specify the following when ordering:

  1. Product model: PXB6-63.
  2. Number of poles: 1P, 2P, 3P or 4P.
  3. Rated current and tripping curve, for example C/16A:
    • Tripping curve (type): B, C or D.
    • Rated current (In): 6, 10, 16, 20, 25, 32, 40, 50 or 63 A.
  4. Quantity, for example 120 pcs.

Ordering example: PXB6-63 1P C/16A, 120 pcs. This is an example order, not a minimum order quantity.

Pengujian Instalasi dan Koordinasi

  • Verify conductor material and cross-section against the circuit calculation and the published terminal range.
  • Confirm the prospective short-circuit current does not exceed the applicable breaking rating.
  • Check upstream/downstream coordination, enclosure temperature, grouping, altitude and required clearances.
  • Installation, isolation, testing and maintenance must be carried out by qualified personnel under applicable rules.

Penamaan tipe

PXB6-63 miniature circuit breaker type designation

Tripping curves

PXB6-63 B C and D tripping curves

Dimensi (mm)

PXB6-63 1P 2P 3P and 4P installation dimensions in millimetres

Spesifikasi Teknis

Parameter Spesifikasi
Rated Insulation Voltage (Ui) 500V
Rated Impulse Withstand Voltage (Uimp) 4000V
Rated Current (In) 6, 10, 16, 20, 25, 32, 40, 50, 63
Rated Frequency 50Hz / 60Hz
Number of Poles 1P, 2P, 3P, 4P
Rated Short-Circuit Breaking Capacity (Icu = Ics) 6000A
Mechanical Endurance 20000
Electrical Endurance 10000
Tripping Curves B, C, D
Terminal Center Distance 45mm
Protection Class IP20
Standard IEC 60898-1; GB/T 10963.1
Sertifikasi CE · CB · CCC | DEKRA Certified

Tripping Characteristics (Reference Temperature: 30°C)

Item Tripping Curve Test Current (A) Initial Status Time limit for tripping or non-tripping Expected result Remarks
a B, C, D 1.13In Cold t ≤ 1h Non-tripping Current smoothly rises to specified value within 5s
b B, C, D 1.45In Following item a test t < 1h Tripping
c B, C, D 2.55In Cold 1s < t < 60s (In ≤ 32A)
1s < t < 120s (In > 32A)
Tripping
d B 3In Cold t ≤ 0.1s Non-tripping Switch on the power supply by closing the auxiliary switch
C 5In
D 10In
e B 5In Cold t < 0.1s Tripping Switch on the power supply by closing the auxiliary switch
C 10In
D 20In

Note: The term “cold” means that the test is carried out at a reference calibration temperature without load before the test.

Persyaratan konduktor dan bagian penampang

Sisi pelipis tembaga (mm2) Rated current In(A)
1 In≤6
1.5 6<In≤13
2.5 13<In≤20
4 20<In≤25
6 25<In≤32
10 32<In≤50
16 50<In≤63

Mengapa Memilih CHAC

Dengan pengalaman manufaktur lebih dari 30 tahun, 1100+ karyawan, dan 100M+ tiang
kapasitas tahunan dan produksi otomatis 90% unit, CHAC memberikan kapasitas produksi yang stabil dan ketat
Pengendalian kualitas untuk pelanggan OEM/ODM global. Sistem manufaktur internal kami mendukung jangka panjang
Kerjasama untuk merek-merek listrik, importir dan distributor.

Gambar produk pemutus sirkuit udara seri Cqw2
30+

BERKALI-KALI BERKEMBANG

Mengkhususkan diri dalam manufaktur listrik tegangan rendah

Gambar produk pemutus sirkuit udara seri Cqw2
1100+

KARYAWAN

Tim profesional memastikan kualitas dan pengiriman yang stabil

Gambar produk pemutus sirkuit udara seri Cqw2
100 juta+

Kapasitas Bulanan POKER

Kapasitas produksi berskala besar untuk memenuhi permintaan global

Gambar produk pemutus sirkuit udara seri Cqw2
90%

PENGELOLAAN PRODUKSI AUTOMATIS

Otomasi canggih untuk efisiensi dan konsistensi yang tinggi

PXB6-63 Miniature Circuit Breaker product image

Barisan Perakitan Otomatis

PXB6-63 Miniature Circuit Breaker product image

Laboratorium Pengujian

PXB6-63 Miniature Circuit Breaker product image

Injeksi & Stamping

PXB6-63 Miniature Circuit Breaker product image

Pemeriksaan Kualitas

PXB6-63 Miniature Circuit Breaker product image
PXB6-63 Miniature Circuit Breaker product image
PXB6-63 Miniature Circuit Breaker product image
PXB6-63 Miniature Circuit Breaker product image
PXB6-63 Miniature Circuit Breaker product image

Sistem kontrol kualitas yang ketat memastikan setiap produk memenuhi standar global.

Apa yang Dapat Kami Sesuaikan?

For PXB6-63 projects, CHAC can review private-label marking, packaging, appearance, available electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, MOQ and project feasibility.

Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Logo & Branding

Pilihan penandaan merek pribadi dan plakat nama tunduk pada pemeriksaan karya seni dan persetujuan sampel.

PXB6-63 Miniature Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Kemasan
Kustomisasi

Kotak karton, label, dan manual dapat disiapkan sesuai spesifikasi pesanan yang telah disetujui dan pasar tujuan.

PXB6-63 Miniature Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Elektrik
Kustomisasi

Select from the published 6A–63A, 1P / 2P / 3P / 4P and B / C / D options; non-standard requests require technical evaluation.

PXB6-63 Miniature Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Produk
Penampilan

Pilihan tampilan dapat ditinjau kembali berdasarkan ketersediaan alat, minimum order pembelian (MOQ), persyaratan penandaan, dan kelayakan teknis.

PXB6-63 Miniature Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Sertifikasi
Dukungan

Datasheets, drawings and verified certificate information are supplied for the applicable approved configuration.

PXB6-63 Miniature Circuit Breaker product image
Pxb6Hdc 125M Dc Miniature Circuit Breaker gambar produk

Teknologi
Pembangunan

Penunjang proyek dapat mencakup review desain, evaluasi sampel, pengujian, dan perencanaan produksi, dengan ketentuan persetujuan teknis.

PXB6-63 Miniature Circuit Breaker product image

Unduh

PDF

PXB6 Series Miniature Circuit Breaker

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Butuh Dokumen Teknis?

Hubungi kami untuk mendapatkan data spesifikasi, sertifikat, gambar, panduan pemilihan, atau dukungan proyek OEM/ODM.

Hubungi Kami

PXB6-63 Product FAQ

What does the 6kA rating on the PXB6-63 MCB mean?

It is the published short-circuit breaking capacity, stated as 6kA Icu = Ics for the relevant product data. It does not describe normal circuit loading.

What is the difference between a 6A MCB and a 6kA MCB rating?

6A is a rated-current value for normal load and conductor protection; 6kA is 6,000A of short-circuit interrupting capacity under stated conditions. They describe different functions.

How many amperes is 6kA?

6kA equals 6,000A. This is a fault-current value, while PXB6-63 continuous rated-current options are published separately as 6A–63A.

What is the main difference between 6kA and 10kA breakers?

The main difference is the stated short-circuit breaking capacity. Select the required level from the prospective fault current, product standard and coordination study.

Would a higher kA breaker always be better than PXB6-63?

Not by itself. A higher verified duty may be required for a higher fault level, but curve, rated current, poles, voltage, standard, dimensions and coordination must also match.

Does kA determine the maximum normal load of a breaker?

No. kA relates to short-circuit interruption. Normal load is governed by the ampere rating, conductor design, installation conditions and applicable rules.

How does the PXB6-63 miniature circuit breaker work?

PXB6-63 automatically opens the circuit when an overload or short circuit triggers its protective mechanism. Its thermal response allows a time delay for overloads, while its magnetic response operates at higher fault currents according to the selected B, C or D curve. Use the published time-current characteristics to check the required disconnection time for your circuit.

How do I choose the rated current for a PXB6-63 MCB?

PXB6-63 is available in 6, 10, 16, 20, 25, 32, 40, 50 and 63 A ratings. Choose a rating that suits the design load and protects the cable within its calculated current-carrying capacity. Account for installation method, ambient temperature, grouping, load inrush and local electrical rules. The 63 A frame designation does not mean every circuit should use a 63 A breaker.

What do B, C and D tripping curves mean for PXB6-63?

The curves distinguish the magnetic tripping bands: B is 3–5 times rated current, C is 5–10 times and D is 10–20 times. These are current multiples, not operating-time values. PXB6-63 offers all three curves. Select a curve that accommodates the actual load inrush while meeting fault-disconnection requirements; do not move to C or D simply to stop unexplained tripping.

How do I choose between 1P, 2P, 3P and 4P PXB6-63 breakers?

PXB6-63 is available in 1P, 2P, 3P and 4P configurations. Choose according to the supply arrangement and which conductors must be switched and protected together. A single-phase circuit may require one-pole or two-pole switching, while three-phase circuits may require three-pole or four-pole switching. Confirm neutral treatment, the product connection diagram and local installation rules rather than selecting by pole count alone.

Can an RCCB replace the PXB6-63 MCB?

An RCCB does not replace PXB6-63 overload and short-circuit protection. An RCCB detects residual current, whereas PXB6-63 is an MCB and does not provide residual-current protection. Where both functions are required, the circuit needs a suitably coordinated MCB and RCCB, or an appropriate RCBO combining the two functions. Select residual-current type and sensitivity according to the application and local rules.

Confirm the Right PXB6-63 Configuration

Send your current rating, pole arrangement, trip option, system voltage, prospective fault level, destination market and quantity. CHAC will review the request against the published product range.

Minta Penawaran Harga