قاطع الدائرة المصغر PXB6-63

ال PXB6-63 miniature circuit breaker provides overload and short-circuit protection within the published 6A–63A range. Its verified product data lists 6kA Icu = Ics, 1P / 2P / 3P / 4P and B / C / D. Final selection must match the conductor, load, prospective fault current, installation system and applicable local rules.

بولنديون
لاعب 1 / لاعبان / 3 لاعبين / 4 لاعبين
التيار المقنن
6A–63A
Electrical Rating:
500V rated insulation voltage (Ui)
Frequency:
50/60 هرتز
Breaking Data:
6kA Icu = Ics
Trip / Residual Type:
B / C / D
قياسي
Version A: IEC 60898-1; Version B: IEC 60947-2; GB/T 10963.1
Mounting:
45mm terminal-centre reference

Product Overview

PXB6-63 is a 6kA Icu = Ics miniature circuit breaker covering 6A–63A. It is available with 1P / 2P / 3P / 4P and B / C / D trip options as stated in the product data.

The model data references Version A: IEC 60898-1; Version B: IEC 60947-2; GB/T 10963.1 and lists CCC certification. Standards, certification scope and technical documents must be confirmed for the ordered configuration and destination market.

Key Features

  • Published current range: 6A–63A.
  • Pole configuration: 1P / 2P / 3P / 4P.
  • Trip / protection option: B / C / D.
  • Short-circuit data: 6kA Icu = Ics.
  • Electrical reference: 500V rated insulation voltage (Ui), 50/60Hz.
  • Service-life data: ≥10,000 mechanical and ≥4,000 electrical operations.
  • Additional verified data: 4kV Uimp; IP20; conductor reference up to 16mm².

Typical Applications

It is intended for AC distribution circuits where the selected current rating, curve, pole arrangement and breaking capacity match the conductor and system study. Typical project contexts include residential, commercial and light-industrial final distribution; suitability depends on the actual circuit rather than the application label alone.

Applications and Selection Guide

Use the product-specific values below as a shortlist, then validate the complete circuit design. Product ratings do not replace a fault-current study, conductor calculation, coordination review or applicable installation rules.

Selection point PXB6-63 option What the project must confirm
Rated current 6A–63A Coordinate with design current, conductor ampacity, ambient temperature and grouping
Trip curve B / C / D Choose for load inrush and required fault-clearing performance, not by current alone
Breaking capacity 6kA Icu = Ics Confirm against the prospective short-circuit current at the installation point
ترتيب الأقطاب لاعب 1 / لاعبان / 3 لاعبين / 4 لاعبين Match supply system and local switching or isolation rules
Installation interface 45mm terminal-centre reference Check enclosure, rail/base, terminal and conductor compatibility

Breaking Capacity

6kA Icu = Ics is the published product value. Confirm the prospective short-circuit current at the installation point.

Fault LevelProject Selection

Trip and Load Behaviour

B / C / D is the available trip/protection option. Match it to load inrush and required disconnection performance.

Load InrushProject Selection

Pole Configuration

Available arrangement: 1P / 2P / 3P / 4P. Confirm which conductors must be switched and protected under local rules.

Circuit LayoutProject Selection

MCB or RCBO

An MCB does not replace residual-current protection where an RCD or RCBO is required.

Protection ScopeProject Selection

Ordering Guide

  1. Specify the exact model: PXB6-63.
  2. State the required current rating within 6A–63A.
  3. Confirm pole arrangement: 1P / 2P / 3P / 4P.
  4. Confirm trip or protection option: B / C / D.
  5. Provide system voltage, expected fault level, destination market, quantity and any document requirements.

Installation and Coordination Checks

  • Verify conductor material and cross-section against the circuit calculation and the published terminal range.
  • Confirm the prospective short-circuit current does not exceed the applicable breaking rating.
  • Check upstream/downstream coordination, enclosure temperature, grouping, altitude and required clearances.
  • Installation, isolation, testing and maintenance must be carried out by qualified personnel under applicable rules.

تعيين النوع

Tripping curves

الأبعاد (مم)

المواصفات الفنية

معامل
Rated Insulation Voltage (Ui) 500V
Rated Impulse Withstand Voltage (Uimp) 4000V
Rated Current (In) 6, 10, 16, 20, 25, 32, 40, 50, 63
Rated Frequency 50Hz / 60Hz
Number of Poles 1P, 2P, 3P, 4P
Rated Short-Circuit Breaking Capacity (Icu = Ics) 6000A
Mechanical Life ≥10000
Electrical Life ≥4000
Tripping Curves B, C, D
Terminal Center Distance 45mm
Protection Class IP20
قياسي Version A: IEC60898-1, GB/T10963.1;
Version B: IEC60947-2
شهادة CCC

Tripping Characteristics (Reference Temperature: 30°C)

Item Tripping Curve Test Current (A) Initial Status Time limit for tripping or non-tripping Expected result Remarks
a B, C, D 1.13In Cold t ≤ 1h Non-tripping Current smoothly rises to specified value within 5s
b B, C, D 1.45In Following item a test t < 1h Tripping
c B, C, D 2.55In Cold 1s < t < 60s (In ≤ 32A)
1s < t < 120s (In > 32A)
Tripping
d B 3In Cold t ≤ 0.1s Non-tripping Switch on the power supply by closing the auxiliary switch
C 5In
D 10In
e B 5In Cold t < 0.1s Tripping Switch on the power supply by closing the auxiliary switch
C 10In
D 20In

Note: The term “cold” means that the test is carried out at a reference calibration temperature without load before the test.

متطلبات الموصل والمقطع العرضي

مقطع عرضي للنحاس (مم2) التيار المقنن In(A)
1 In≤6
1.5 6<In≤13
2.5 13<In≤20
4 20<In≤25
6 25<In≤32
10 32<In≤50
16 50<In≤63

لماذا تختار CHAC

مع خبرة تصنيع تزيد عن 30 عامًا، وأكثر من 1100 موظف، وأكثر من 100 مليون عمود
بفضل طاقتها الإنتاجية السنوية ونظام الإنتاج الآلي 90%، توفر شركة CHAC طاقة إنتاجية مستقرة ومعايير صارمة
مراقبة الجودة لعملاء OEM/ODM العالميين. يدعم نظام التصنيع الداخلي الخاص بنا على المدى الطويل
تعاون مع العلامات التجارية الكهربائية والمستوردين والموزعين.


30+

سنوات الخبرة

متخصص في تصنيع المعدات الكهربائية منخفضة الجهد


1100+

الموظفين

فريق محترف يضمن جودة ثابتة والتسليم


١٠٠ مليون+

السعة السنوية للأعمدة

قدرة إنتاجية واسعة النطاق لتلبية الطلب العالمي


90%

الإنتاج الآلي

الأتمتة المتقدمة لتحقيق كفاءة واتساق عاليين

خط التجميع الآلي

خط التجميع الآلي

مختبر اختبار

مختبر اختبار

حقن وختم

حقن وختم

فحص الجودة

فحص الجودة

شهادة IEC
شهادة CE
شهادة CB
شهادة RoHS
شهادة الآيزو 14001

نظام صارم لمراقبة الجودة يضمن أن كل منتج يلبي المعايير العالمية.

ما الذي يمكننا تخصيصه؟

For PXB6-63 projects, CHAC can review private-label marking, packaging, appearance, available electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, MOQ and project feasibility.

الشعار والعلامة التجارية

Private-label marking and nameplate options are subject to artwork review and sample approval.

الشعار والعلامة التجارية

تعبئة وتغليف
تخصيص

Cartons, labels and manuals can be prepared for the approved order specification and destination market.

تخصيص التعبئة والتغليف

كهربائي
تخصيص

Select from the published 6A–63A, 1P / 2P / 3P / 4P and B / C / D options; non-standard requests require technical evaluation.

تخصيص كهربائي

منتج
مظهر

Appearance options can be reviewed subject to tooling, MOQ, marking requirements and technical feasibility.

مظهر المنتج

شهادة
دعم

Datasheets, drawings and verified certificate information are supplied for the applicable approved configuration.

دعم الشهادات

الهندسة
تطوير

Project support may include drawing review, sample evaluation, testing and production planning, subject to technical approval.

التطوير الهندسي

تنزيل

ملف PDF

قاطع الدائرة المصغر سلسلة PXB6

نظرة عامة كاملة على مكونات كهربائية منخفضة الجهد ومرجع لاختيار المنتج.

تحميل ملف PDF

سوب

هل تحتاج إلى وثائق فنية؟

اتصل بنا للحصول على أوراق البيانات، والشهادات، والرسومات، وإرشادات الاختيار، أو دعم مشاريع OEM/ODM.

اتصل بنا

PXB6-63 Product FAQ

What does the 6kA rating on the PXB6-63 MCB mean?

It is the published short-circuit breaking capacity, stated as 6kA Icu = Ics for the relevant product data. It does not describe normal circuit loading.

What is the difference between a 6A MCB and a 6kA MCB rating?

6A is a rated-current value for normal load and conductor protection; 6kA is 6,000A of short-circuit interrupting capacity under stated conditions. They describe different functions.

How many amperes is 6kA?

6kA equals 6,000A. This is a fault-current value, while PXB6-63 continuous rated-current options are published separately as 6A–63A.

What is the main difference between 6kA and 10kA breakers?

The main difference is the stated short-circuit breaking capacity. Select the required level from the prospective fault current, product standard and coordination study.

Would a higher kA breaker always be better than PXB6-63?

Not by itself. A higher verified duty may be required for a higher fault level, but curve, rated current, poles, voltage, standard, dimensions and coordination must also match.

Does kA determine the maximum normal load of a breaker?

No. kA relates to short-circuit interruption. Normal load is governed by the ampere rating, conductor design, installation conditions and applicable rules.

Confirm the Right PXB6-63 Configuration

Send your current rating, pole arrangement, trip option, system voltage, prospective fault level, destination market and quantity. CHAC will review the request against the published product range.

Request a Quote