ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector

O ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector is a CHAC surge protection device for transient overvoltage protection. The page keeps the model-specific technical table and original product images so buyers can verify voltage, current, configuration, mounting and applicable standards before ordering. Final suitability depends on the complete circuit, installation method and destination-market rules.

Product family:
SPD
Primary function:
transient overvoltage protection
Typical context:
PV, building distribution and control panels
Technical data:
See verified model table below
Configuration:
Confirm the exact model variant
Support:
OEM/ODM review available

Visão Geral do Produto

ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector is a surge protection device intended for transient overvoltage protection. The current product record identifies it for PV, building distribution and control panels. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.

Verified source summary: Dimensions(mm) Technical Specifications Parameter Rated voltage (max. continuous AC voltage) 275V or 385V Lightning impulse current (10/350) [limp] 7 kA Nominal discharge current (8/20) [In] 20 kA Maximum discharge current [Imax] 50 kA Voltage protection level [Up] ≤ 1.5 kV Follow current extinguishing capability at Uc 32A fuse will not be triggered at 2kA…255V Response time [t] ≤ 100 ns Max. backupfuse (L) 200A gL

Principais Características

  • Product type: surge protection device.
  • Primary function: transient overvoltage protection.
  • Application context: PV, building distribution and control panels.
  • Model variants, dimensions and ratings remain in the preserved technical source.
  • Confirm installation method, environmental limits and local compliance before release.

Aplicações Típicas

Typical use can include PV, building distribution and control panels when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.

Guia de Candidaturas e Seleção

Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.

Ponto de seleção ExS-T1T2-AC Series Single-Pole Pluggable Surge Protector O que o projeto deve confirmar
Aplicação SPD projects Confirm the actual system and environment
Selection basis transient overvoltage protection Use the exact model and technical table
Instalação Follow the model instructions Check mounting, clearances and termination
Compliance Use the listed standard where applicable Verify edition, scope and destination rules
Adjacent product Evaluate the related CHAC family where function differs Do not substitute without engineering review

Function

transient overvoltage protection

Match the protection or switching function to the system.

View related guidance →

Configuração

Model-specific options

Confirm current, voltage, poles, terminals or accessories from the table.

View related guidance →

Instalação

Mechanical and electrical fit

Check enclosure, mounting, wiring space and maintenance access.

View related guidance →

Project evidence

Documents and test records

Retain the approved drawing, technical sheet and commissioning record.

View related guidance →

Guia de Encomenda

  1. State the exact model and variant.
  2. Provide the system voltage, current, frequency and load or protection function.
  3. Confirm mounting, terminals, accessories, enclosure and environmental conditions.
  4. Share quantity, destination market and required technical documents.

Verificações de Instalação e Coordenação

  • Verify the model’s ratings and connection arrangement against the project drawings.
  • Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
  • Coordinate upstream and downstream protection or control devices where applicable.
  • Use qualified personnel for installation, testing, isolation and maintenance.

Dimensões (mm)

Especificações Técnicas

Parâmetro  
Rated voltage (max. continuous AC voltage) 275V or 385V
Lightning impulse current (10/350) [limp] 7 kA
Nominal discharge current (8/20) [In] 20 kA
Maximum discharge current [Imax] 50 kA
Voltage protection level [Up] ≤ 1.5 kV
Follow current extinguishing capability at Uc 32A fuse will not be triggered at 2kA…255V
Response time [t] ≤ 100 ns
Max. backupfuse (L) 200A gL/gG
Max. backupfuse (L-L’) 125A gL/gG
TOV voltage 355V/5sec
Operating temperature range (parallel wiring) -40℃ to +80℃
Operating temperature range (through wiring) -40℃ to +60℃
Terminal cross-sectional area 35 mm2 solid / 50 mm2 flexible
Mounting on 35mm DIN rail
Enclosure material Purple (module)/light gray (base) thermoplastic, UL94-V0
Dimensão 2 modules
Type of remote signalling contact Switching contact
Switching capacity AC 250V/0.5A
Switching capacity DC 250V / 0.1A; 125V / 0.2A; 75V / 0.5A
Cross-sectional area for remote signalling contact Max. 1.5 mm2 solid/flexible
Normas IEC 61643-11; GB 18802.1; YD/T 1235.1
Certificação CE, RoHS, ISO 9001, CQC,TUV

Porquê escolher a CHAC

Com mais de 30 anos de experiência em fabrico, mais de 1100 funcionários, mais de 100 milhões de postes
Com uma capacidade anual e um processo de produção automatizado 90%, a CHAC garante uma capacidade de produção estável e rigorosos
Controlo de qualidade para clientes OEM/ODM globais. O nosso sistema de fabrico interno suporta a longo prazo
cooperação para marcas elétricas, importadores e distribuidores.


30+

ANOS DE EXPERIÊNCIA

Especializado em fabrico de baixa tensão elétrica


1100+

FUNCIONÁRIOS

Equipa profissional garante qualidade e entrega estáveis


100M+

CAPACIDADE ANUAL DE POSTOS

Capacidade de produção em larga escala para satisfazer a procura global


90%

PRODUÇÃO AUTOMATIZADA

Automação avançada para alta eficiência e consistência

Linha de Montagem Automatizada

Linha de Montagem Automatizada

Laboratório de Ensaios

Laboratório de Ensaios

Injeção e Estampagem

Injeção e Estampagem

Inspeção de Qualidade

Inspeção de Qualidade

Certificação IEC
Certificação CE
Certificação CB
Certificação RoHS
Certificação ISO 14001

Um rigoroso sistema de controlo de qualidade garante que cada produto cumpre as normas globais.

O que podemos personalizar?

Apoiamos a personalização em termos de imagem de marca, embalagem, aparência do produto,
especificações elétricas, requisitos de certificação e desenvolvimento de engenharia. Quer os clientes
se necessita de produtos de marca própria, parâmetros específicos de mercado ou desenvolvimento de novos produtos, a CHAC pode fornecer
soluções flexíveis com base nos requisitos do projeto.

Logótipo e Identidade Visual

Impressão de logótipos personalizados, marcação a laser e soluções de placas de identificação.

Logótipo e Identidade Visual

Embalagem
Personalização

Caixas, embalagens, etiquetas e manuais personalizados com cores.

Personalização de Embalagens

Elétrico
Personalização

Corrente, tensão, poder de corte, curva de disparo e outros
funções especiais.

Personalização Elétrica

Produto
Aparência

Cor da caixa, cor da pega e personalização da aparência.

Aparência do Produto

Certificação
Apoio

Os produtos cumprem os padrões internacionais e de mercado
requisitos.

Suporte de Certificação

Engenharia
Desenvolvimento

Avaliação do desenho, teste do protótipo e produção em massa.

Desenvolvimento de engenharia

Transferir

PDF

Disjuntor em Miniatura Série CQB3

Visão geral completa de componentes elétricos de baixa tensão e referência para seleção de produtos.

Transferir PDF

SUP

Precisa de Documentos Técnicos?

Contacte-nos para folhas de dados, certificados, desenhos, orientação de seleção ou suporte a projetos OEM/ODM.

Contacte-nos

ExS-T1T2-AC Product FAQ

What does the ExS-T1T2-AC SPD protect?

It is intended to limit transient overvoltage in the system stated by the product record. Confirm the AC or DC system, protection zone, discharge rating and backup protection for the selected variant.

How do I choose an SPD discharge rating?

Use the project's lightning and transient exposure, system arrangement and the device's published In, Imax or Iimp values. Do not select by nominal voltage alone.

Does an SPD replace a circuit breaker?

No. An SPD diverts transient energy, while a breaker or fuse provides overcurrent protection. The two devices must be coordinated.

What should be checked before installation?

Check voltage, wiring mode, earthing, backup fuse, lead length, enclosure and the manufacturer's connection diagram.

When should the module be replaced?

Use the status indicator and the product instructions. Investigate the cause of a fault indication before fitting a replacement module.

What documents can CHAC provide?

Request the applicable datasheet, wiring diagram, dimensions and verified compliance documents for the ordered configuration.

Confirm the Right ExS-T1T2-AC Configuration

Send the exact model, operating conditions, quantity, destination market and required documents. CHAC will review the request against the published product data.

Pedir um orçamento