Disjuntor DC em Miniatura PXB6DC-125M
O PXB6DC-125M is specified for DC overload and short-circuit protection. Select it using the published voltage, current, pole and protection data, then confirm conductor coordination, fault conditions, enclosure requirements and local installation rules.
Visão Geral do Produto
PXB6DC-125M is a DC circuit breaker 125A for DC voltage and pole limits vary by model table applications. It is intended for PV, telecom, energy-storage or control circuits when the DC fault study supports the rating; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.
DC overload and short-circuit protection is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.
Principais Características
Aplicações Típicas
PV, telecom, energy-storage or control circuits when the DC fault study supports the rating. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.
Guia de Candidaturas e Seleção
Use the verified PXB6DC-125M records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.
| Ponto de seleção | PXB6DC-125M reference | O que o projeto deve confirmar |
|---|---|---|
| Corrente nominal | Use the exact model table | Design current, conductor capacity, ambient and grouping |
| Tensão e frequência | DC voltage and pole limits vary by model table | Sistema de alimentação e classificação de equipamento |
| Polacos | 1P / 2P / 3P / 4P as listed | Conductors to be switched, protected or isolated |
| Protection / control | DC overload and short-circuit protection | Required function and adjacent-device coordination |
| Fault / residual data | Use the exact model's DC interruption data | Prospective short-circuit or leakage conditions |
AC vs DC Interruption
DC interruption duty is not interchangeable with AC. Confirm the model's DC voltage, pole arrangement, Icu/Ics and wiring instructions.
DC Fault Duty
Review Circuit Protection →
Model-Specific Ratings
Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.
Verified Data
View Technical Support →
Installation and Coordination
Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.
Engineering Check
Discuss a Configuration →
Ordering Information
State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.
Project Inputs
Send Project Details →
Guia de Encomenda
- State the exact model: PXB6DC-125M.
- Provide rated current and voltage from the published technical table.
- Confirm poles and the required protection, isolation or control function.
- Provide application, expected fault/leakage conditions, destination market and quantity.
- List accessory, terminal, documentation and approved marking or packaging requirements.
Verificações de Instalação e Coordenação
- Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
- Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
- Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
- Installation, testing and maintenance must be completed by qualified personnel under applicable rules.
Designação do tipo

Dimensões (mm)

Especificações Técnicas
| Parâmetro | |
| Rated Voltage (V) | 1P DC24V/48V/80V/110V/125V 2P DC24V/48V/80V/110V/125V/160V/220V/250V |
| Rated Current (A) | 63, 80, 100, 125 |
| Tensão de Isolação Nominal (Ui) | 500V |
| Número de Polos | 1P, 2P |
| Tensão nominal de impulso suportada Uimp (kV) | 4 |
| Ultimate Breaking Capacity (Icu) (kA) | 10 |
| Service Breaking Capacity (Ics) (kA) | 7.5 |
| Mechanical Life (operations) | ≥10000 |
| Electrical Life (operations) | ≥1500 |
| Pollution Degree | 3 |
| Padrão | GB/T14048.2、IEC60947-2 |
| Certificação | CCC |
Tripping Characteristics (Reference Temperature: 30℃)
| Artigo | Test Current (A) | Estado Inicial | Prazo para tropeçar ou não tropeçar | Resultado esperado | Observações |
| a | 1.05In | Frio | t ≤ 2h ( In > 63A) | Não disparável | Current smoothly rises to specified value within 5s |
| t ≤ 1h ( In ≤ 63A) | |||||
| b | 1.3In | Following item a test | t < 2h ( In > 63A) | Viagem | |
| t < 1h ( In ≤ 63A) | |||||
| c | 2,55 pol | Frio | 1s < t < 60s ( In ≤ 32A) 1s < t < 120s ( In > 32A) |
Viagem | |
| d | 4In、8In、12In (±20%) | Frio | t ≤ 0.2s | Viagem | Circuit switched on by closing an auxiliary switch. Verifies rapid breaking capability. |
Note: The term “cold” means that the test is carried out at a reference calibration temperature without load before the test
Porquê escolher a CHAC
Com mais de 30 anos de experiência em fabrico, mais de 1100 funcionários, mais de 100 milhões de postes
Com uma capacidade anual e um processo de produção automatizado 90%, a CHAC garante uma capacidade de produção estável e rigorosos
Controlo de qualidade para clientes OEM/ODM globais. O nosso sistema de fabrico interno suporta a longo prazo
cooperação para marcas elétricas, importadores e distribuidores.

30+
ANOS DE EXPERIÊNCIA
Especializado em fabrico de baixa tensão elétrica

1100+
FUNCIONÁRIOS
Equipa profissional garante qualidade e entrega estáveis

100M+
CAPACIDADE ANUAL DE POSTOS
Capacidade de produção em larga escala para satisfazer a procura global

90%
PRODUÇÃO AUTOMATIZADA
Automação avançada para alta eficiência e consistência

Linha de Montagem Automatizada

Laboratório de Ensaios

Injeção e Estampagem

Inspeção de Qualidade





Um rigoroso sistema de controlo de qualidade garante que cada produto cumpre as normas globais.
O que podemos personalizar?
For PXB6DC-125M projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.
Logótipo e Identidade Visual
Impressão de logótipos personalizados, marcação a laser e soluções de placas de identificação.

Embalagem
Personalização
Caixas, embalagens, etiquetas e manuais personalizados com cores.

Elétrico
Personalização
Corrente, tensão, poder de corte, curva de disparo e outros
funções especiais.

Produto
Aparência
Cor da caixa, cor da pega e personalização da aparência.

Certificação
Apoio
Os produtos cumprem os padrões internacionais e de mercado
requisitos.

Engenharia
Desenvolvimento
Avaliação do desenho, teste do protótipo e produção em massa.

Transferir
Disjuntor em Miniatura Série PXB6
Visão geral completa de componentes elétricos de baixa tensão e referência para seleção de produtos.
Precisa de Documentos Técnicos?
Contacte-nos para folhas de dados, certificados, desenhos, orientação de seleção ou suporte a projetos OEM/ODM.
PXB6DC-125M Product FAQ
What is the PXB6DC-125M used for?
The PXB6DC-125M is specified for DC overload and short-circuit protection in DC voltage and pole limits vary by model table applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.
How does the PXB6DC-125M work?
Its operating principle follows the documented function: DC overload and short-circuit protection. Use the exact model documentation for thresholds, timing, trip behaviour, terminals and test procedures.
How do I choose the PXB6DC-125M rating and poles?
Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 1P / 2P / 3P / 4P as listed; confirm neutral, polarity, conductors and isolation requirements.
What safety limitation applies to the PXB6DC-125M?
Do not treat the PXB6DC-125M as a universal substitute for another device. Confirm Use the exact model's DC interruption data, the system voltage, fault or leakage conditions and any separate upstream protection before selection.
Can the PXB6DC-125M be used in another circuit type?
Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.
How should the PXB6DC-125M be installed and tested?
Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.
Confirm the Right PXB6DC-125M Configuration
Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.