PXB6DC-125M DC Miniature Circuit Breaker

The PXB6DC-125M is specified for DC overload and short-circuit protection. Select it using the published voltage, current, pole and protection data, then confirm conductor coordination, fault conditions, enclosure requirements and local installation rules.

Poles:
1P / 2P / 3P / 4P as listed
Rated Current:
63–125A
Rated Voltage:
DC voltage and pole limits vary by model table
Primary Function:
DC overload and short-circuit protection
Selection Data:
Use the exact model's DC interruption data
Standard:
IEC 60947-2 references

Product Overview

PXB6DC-125M is a DC circuit breaker 125A for DC voltage and pole limits vary by model table applications. It is intended for PV, telecom, energy-storage or control circuits when the DC fault study supports the rating; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.

DC overload and short-circuit protection is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.

Key Features

  • Published pole options: 1P / 2P / 3P / 4P as listed.
  • Published electrical context: DC voltage and pole limits vary by model table.
  • Primary function: DC overload and short-circuit protection.
  • Selection reference: Use the exact model's DC interruption data.
  • Applicable standard reference: IEC 60947-2 references.
  • Final selection must use the exact model table, drawings and installation instructions.

Typical Applications

PV, telecom, energy-storage or control circuits when the DC fault study supports the rating. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.

Applications and Selection Guide

Use the verified PXB6DC-125M records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.

Selection point PXB6DC-125M reference What the project must confirm
Rated current Use the exact model table Design current, conductor capacity, ambient and grouping
Voltage and frequency DC voltage and pole limits vary by model table Supply system and equipment rating
Poles 1P / 2P / 3P / 4P as listed Conductors to be switched, protected or isolated
Protection / control DC overload and short-circuit protection Required function and adjacent-device coordination
Fault / residual data Use the exact model's DC interruption data Prospective short-circuit or leakage conditions

AC vs DC Interruption

DC interruption duty is not interchangeable with AC. Confirm the model's DC voltage, pole arrangement, Icu/Ics and wiring instructions.

DC Fault Duty
Review Circuit Protection →

Model-Specific Ratings

Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.

Verified Data
View Technical Support →

Installation and Coordination

Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.

Engineering Check
Discuss a Configuration →

Ordering Information

State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.

Project Inputs
Send Project Details →

Ordering Guide

  1. State the exact model: PXB6DC-125M.
  2. Provide rated current and voltage from the published technical table.
  3. Confirm poles and the required protection, isolation or control function.
  4. Provide application, expected fault/leakage conditions, destination market and quantity.
  5. List accessory, terminal, documentation and approved marking or packaging requirements.

Installation and Coordination Checks

  • Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
  • Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
  • Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
  • Installation, testing and maintenance must be completed by qualified personnel under applicable rules.

Type designation

Dimensions(mm)

Technical Specifications

Parameter
Rated Voltage (V) 1P DC24V/48V/80V/110V/125V
2P DC24V/48V/80V/110V/125V/160V/220V/250V
Rated Current (A) 63, 80, 100, 125
Rated Insulation Voltage (Ui) 500V
Number of Poles 1P, 2P
Rated impulse withstand voltage Uimp(kV) 4
Ultimate Breaking Capacity (Icu) (kA) 10
Service Breaking Capacity (Ics) (kA) 7.5
Mechanical Life (operations) ≥10000
Electrical Life (operations) ≥1500
Pollution Degree 3
Standard GB/T14048.2、IEC60947-2
Certification CCC

Tripping Characteristics (Reference Temperature: 30)

Item Test Current (A) Initial Status Time limit for tripping or non-tripping Expected result Remarks
a 1.05In Cold t ≤ 2h ( In > 63A) Non-tripping Current smoothly rises to specified value within 5s
t ≤ 1h ( In ≤ 63A)
b 1.3In Following item a test t < 2h ( In > 63A) Tripping
t < 1h ( In ≤ 63A)
c 2.55In Cold 1s < t < 60s ( In ≤ 32A)
1s < t < 120s ( In > 32A)
Tripping
d 4In、8In、12In (±20%) Cold t ≤ 0.2s Tripping Circuit switched on by closing an auxiliary switch. Verifies rapid breaking capability.

Note: The term “cold” means that the test is carried out at a reference calibration temperature without load before the test

Why Choose CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.


30+

YEARS EXPERIENCE

Specialized in low-voltage electrical manufacturing


1100+

EMPLOYEES

Professional team ensures stable quality and delivery


100M+

POLES ANNUAL CAPACITY

Large-scale production capacity to meet global demand


90%

AUTOMATED PRODUCTION

Advanced automation for high efficiency and consistency

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

IEC Certification
CE Certification
CB Certification
RoHS Certification
ISO 14001 Certification

Strict quality control system ensures every product meets global standards.

What Can We Customize?

For PXB6DC-125M projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.

Logo & Branding

Custom logo printing, laser marking and nameplate solutions.

Logo & Branding

Packaging
Customization

Customized color boxes, cartons, labels and manuals.

Packaging Customization

Electrical
Customization

Current, voltage, breaking capacity, trip curve and other
special functions.

Electrical Customization

Product
Appearance

Housing color, handle color and appearance customization.

Product Appearance

Certification
Support

Products comply with international standards and market
requirements.

Certification Support

Engineering
Development

Drawing evaluation, prototype testing and mass production.

Engineering Development

Download

PDF

PXB6 Series Miniature Circuit Breaker

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Contact Us

PXB6DC-125M Product FAQ

What is the PXB6DC-125M used for?

The PXB6DC-125M is specified for DC overload and short-circuit protection in DC voltage and pole limits vary by model table applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.

How does the PXB6DC-125M work?

Its operating principle follows the documented function: DC overload and short-circuit protection. Use the exact model documentation for thresholds, timing, trip behaviour, terminals and test procedures.

How do I choose the PXB6DC-125M rating and poles?

Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 1P / 2P / 3P / 4P as listed; confirm neutral, polarity, conductors and isolation requirements.

What safety limitation applies to the PXB6DC-125M?

Do not treat the PXB6DC-125M as a universal substitute for another device. Confirm Use the exact model's DC interruption data, the system voltage, fault or leakage conditions and any separate upstream protection before selection.

Can the PXB6DC-125M be used in another circuit type?

Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.

How should the PXB6DC-125M be installed and tested?

Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.

Confirm the Right PXB6DC-125M Configuration

Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.

Request a Quote