CQM6L Leakage-Integrated MCCB OEM/ODM Manufacturer

The CQM6L Leakage-Integrated Molded Case Circuit Breaker adds residual current protection to overload and short-circuit safeguarding for currents 10A to 1250A. Adjustable leakage sensitivity (30-1000mA with time delay) detects ground faults quickly. 3/4 poles, capacities up to 75kA, compliant with IEC/EN 60947 and GB/T 14048 standards. Accessories for comprehensive monitoring, flexible operations, 800V insulation. Designed for high-risk or humid environments like bathrooms or outdoors, it features tested life for enhanced safety and reliability.

Product Features

■ Integrated Safety: Combines the overcurrent protection of a standard MCCB with earth leakage (RCCB) functionality in a single device for enhanced safety.

■ Seamless Compatibility: Shares the same compact dimensions and accessory platform as the standard CQM6 series, allowing for easy upgrades.

■ Selective Tripping: Offers configurable options for the N-pole (protected/unprotected, combinable) to meet specific system grounding requirements.

■ High Reliability: Maintains the proven environmental resilience and mechanical durability of the CQM6 product line.

Compliance

■ Meets international and regional standards including

IEC/EN 60947-1( General Rules)        GB/T 14048.1

IEC/EN 60947-2(Circuit-Breakers)       GB/T 14048.2

IEC/EN 60947-3( Switchgear )          GB/T 14048.3

IEC/EN 60947-4( Contactors & Motor-Starters)       GB/T 14048.4

Accessory List

Selection Guide

Product code ① Shell frame grade ② Breaking capacity ③ Operating method ④ The number of poles ⑤
CQM6L 160 C P 4
Molded
case circuit
breaker
C S M H P:Motorized operation
Z:Turning handle
W.Direct operation
3-pole
4-pole
160 160 25/18 35/25 / /
250 250 25/18 35/25 / /
630 630 / 35/25 50/35 75/75
800 800 / 35/25 50/35 75/75
1250 1250 / 35/25 50/35 75/75
Decoupler method and internal accessories ⑥ Rated current A ⑦ Function ⑧ Optional code for four-pole products ⑨ Special code ⑩
300 160A 2 A I
The first digit indicates the type of detent
2:Instantaneous detent only
3:Duplicate detent Note:The last two digits are the accessory designator(see accessory table).
160 10,16,20,32,40,50,63,80,100,125,140,160 1:For power distribution
2:For motor protection
A:N-pole is unprotected and cannot be combined
B:N-pole is unprotected and can be combined
C:N-pole is protected and can be combined
D:N-pole is protected and cannot be combined
I: Overload alarm non trip function
250 100,125,140,160,180,200,225,250
630 250,315,350,400,500,630
800 500,630,700,800
Product code ⑪ Breaking capacity ⑫
L1 Y1
Fixed delay type Quick three-step adjustable Fixed delay type Quick three-step adjustable
L1:30 L6:200 L11:30,50,100 Y1:0.1S Y4:0.4S Y7:0.7S Y10:1.0S Y13:0.45,1,2
L2:50 L7:300 L12:30,100,200
L3:75 L8:500 L13:30,100,500 Y2:0.2S Y5:0.5S Y8:0.8S Y11:1.1S Y14:1,2,3
L4:100 L9:500 L14:100,300,500
L5:150 L10:1000 L15:100,300,500 Y3:0.3S Y6:0.6S Y9:0.9S Y12:1.2S
L16:100,300,1000
Accessory Voltage ⑬ Motorized operating voltage ⑭ Installation ⑮ Whether to install a terminal block ⑯
Q1 D1 Q 2
Undervoltage detent
Q1:AC220V
Q2:AC240V
Q3:AC380V
Q4:AC415V
Shunt release
F1:AC220V
F2:AC380V
F3:DC110V
F4:DC24V
Auxiliary alarm
J1:AC125V
J2:AC250V
J3:DC125V
J4:DC24V
DC1 Electrical Operation
D1:AC220V
D2:AC230V
D3:AC380V
D4:AC400V
DC3 Electrical Operation
D5:AC230V
D6:AC110V
D7:DC220
D8:DC110
D9:AC110~240V
D10:DC100~220V
Q:Front of plate
H:Rear of plate
C:Inserted
1:No installation
2:Installation
Note:When motorized operation is selected,please refer to the external accessories for the two voltages applicable for motorized operation.

Main Technical Parameters

Model number CQM6L-160 CQM6L-250
Rated current of frame level Inm(A) 160 250
Number of poles 4 4
Rated current In(A),at 40℃,50℃,55℃ 10, 16, 20, 32, 40, 50, 63, 80,100, 125, 160 125,140,160,180,200,225,250
Rated operating voltage Ue(V),AC 50/60Hz 400/415 400/415
Rated insulation voltage Ui (V) 800 800
Rated impulse withstand voltage Uimp(KV) 8 8
Breaking capacity designation C S C S
Short-circuit breaking capacity Icu/Ics(kA) AC400/415V 25/18 35/25 25/18 35/25
Selectivity category A A A A
Number of operating cycles(cycle) ON 6000 6000
OFF 10000 10000
Trip mechanisms and protection types Magnetic trip Power distribution protection
Motor protection
Thermal-magnetic trip Power distribution protection
Motor protection
Accessory Auxiliary contacts
Alarm contacts
Shunt disconnect
Undervoltage detent
Manual operating mechanism
Motorized operating mechanism
Backplane wiring
Inserted
Coupling plate
Partition between phases
Derivative products Dedicated for prepayment electric meters
Overload alarm without trip
Overall dimensions (mm) (a-b-c-ca) 4 P 120-155-70-94 140-165-70-96

Note:● for optional accessories;”-“for no optional accessories.

Model number CQM6L-630 CQM6L-800
Rated current of frame level Inm(A) 630 800
Number of poles 3, 4 4
Rated current In(A),at 40℃,50℃,55℃ 250, 315, 350, 400, 500, 630 500,630,700,800
Rated operating voltage Ue(V),AC 50/60Hz 400/415 400/415
Rated insulation voltage Ui (V) 800 800
Rated impulse withstand voltage Uimp(KV) 8 8
Breaking capacity designation S M H S M H
Short-circuit breaking capacity Icu/Ics(kA) AC400/415V 35/25 50/35 75/75 35/25 50/35 75/75
Selectivity category A A A A A A
Number of operating cycles(cycle) ON 3000 3000
OFF 8000 8000
Trip mechanisms and
protection types
Magnetic trip Power distribution protection
Motor protection
Thermal-magnetic trip Power distribution protection
Motor protection
Accessory Auxiliary contacts
Alarm contacts
Shunt disconnect
Undervoltage detent
Manual operating mechanism
Motorized operating mechanism
Backplane wiring
Inserted
Coupling plate
Partition between phases
Derivative products Dedicated for prepayment electric meters
Overload alarm without trip
Overall dimensions
(mm) (a-b-c-ca)
4 P 185-257-105-155 280-275-105-155

Note:● for optional accessories;”-“for no optional accessories.

Operating Characteristics

1.The inverse time operating characteristics of power distribution circuit breakers when all poles are energized simultaneously at anambient airtemperature of +40℃(with no humidity compensation)are shown in the following table:

Test current designation Setting current multiple Conventional time Initial state
In≤63 In>63
Conventional non-tripping current 1.05 ≥1h ≥2h Cool state
Conventional tripping current 1.3 <1h<2h Hot state

2.The inverse time action characteristics of circuit breakers for motor protection without humidity compensation when all poles areenergizedsimultaneously at an ambient air temperature of +40℃ are shown in the following table:

Test current designation Setting current multiple Conventional time Initial state
In≤800
Conventional non-tripping current 1.0 ≥2h Cool state
Conventional tripping current 1.2 <2h Hot state

3.Action characteristics under short-circuit condition:The short-circuit curent setting value of the instantaneous tripper of the circuit breaker forpower distribution is 10In

The short-circuit current setting value of the instaneous tripper of the circuit breaker for motorprotection is 12ln

The accuracy of the short-circuit curent setting value of the instantaneous tripper is 20% of the short-circuit currentsetting value.

CQM6L-125 Operating Characteristic Curve

CQM6L-250 Operating Characteristic Curve

CQM6L-630 Operating Characteristic Curve

CQM6L-800 Operating Characteristic Curve

CQM6L-1250 Operating Characteristic Curve

Outline and Installation Dimensions(mm)

Molded case
circuit breaker
Overall dimension Installation
dimensions
Bolt
A A1 A2 A3 B B1 B2 B3 B5 B6 H H1 H2 H3 H4 H5 H6 A4 B4
3P 4P 3P 4P 3P 4P 3P 4P
CQM6L-160 120 90 155 134 103 50 50 94 72 4 70 61 41 24 30 132 M8
CQM6L-250 140 105 165 144 103 50 100 96 72 4 70 61 46 24 35 126 M8
CQM6L-630 185 132 196 168 257 230 179 90 110 42 155 107 5 105 97 64 35 44 194 M10
CQM6L-800 280 210 250 210 275 243 192 90 110 87 155 107 5 104 97 65 24 70 242.5 M12

Why Choose CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.


30+

YEARS EXPERIENCE

Specialized in low-voltage electrical manufacturing


1100+

EMPLOYEES

Professional team ensures stable quality and delivery


100M+

POLES ANNUAL CAPACITY

Large-scale production capacity to meet global demand


90%

AUTOMATED PRODUCTION

Advanced automation for high efficiency and consistency

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

IEC Certification
CE Certification
CB Certification
RoHS Certification
ISO 14001 Certification

Strict quality control system ensures every product meets global standards.

What Can We Customize?

Flexible customization services are available for enclosure dimensions, component configuration,
branding and project requirements.

Enclosure Design

Enclosure
Design

Customized enclosure sizes, structures and installation details.

Enclosure Design

Internal Configuration

Internal
Configuration

Flexible internal layout and component arrangement options.

Internal Configuration

Branding and Logo

Branding &
Logo

Private label logos, nameplates and brand identification.

Branding and Logo

Packaging Design

Packaging
Design

Custom cartons, labels, manuals and packaging solutions.

Packaging Design

Electrical Configuration

Electrical
Configuration

Tailored electrical setup based on application requirements.

Electrical Configuration

Certification Support

Certification
Support

Support for target-market standards and compliance requirements.

Certification Support

Download

PDF

CQM6 Series Moulded Case Circuit Breaker

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Contact Us

Frequently Asked Questions

Q1. Do you support product customization based on our design requirements?

A1:Absolutely. We specialize in OEM and ODM cooperation in the low-voltage electrical field and have provided customized services for many internationally renowned companies. We offer full-process support, including R&D design, parameter adjustments, and special material selection, ensuring the product fully meets your requirements.

Q2: What is your production capacity and Minimum Order Quantity (MOQ)?

A2: We operate a highly automated production base with an annual output of over 100 million poles for miniature circuit breakers. Our MOQ policy is flexible. We can provide competitive trial orders for small batches and dedicated production capacity guarantee plans.

Q3: What assurances are there for product quality and certifications?

A3: Our main products are certified with CCC, CE, CB, and more, and are sold in over 30 countries and regions worldwide. The company has established a dedicated Quality Operations Center that works with the business and production departments to implement full-process quality control, ensuring products meet international standards.

Q4: Do you have the capability for product R&D and turning concepts into reality?

A4: We have a complete R&D team and digital workshops, backed by extensive customization experience serving numerous international clients. From concept proposal and sample development to mass production, we provide end-to-end technical support to help bring your ideas to life.