CQC6-Serie Industrielle AC-Schütze - OEM-Hersteller
Der CQC6-Serie Industrielle AC-Schütze - OEM-Hersteller Das ist ein CHAC-AC-Kontaktor für Fernschaltung und Motorsteuerung. Die Seite enthält die modellspezifische technische Tabelle und Originalbilder des Produkts, damit Käufer die Spannung, den Strom, die Konfiguration, die Montage und die anwendbaren Normen vor der Bestellung überprüfen können. Die endgültige Eignung hängt von dem kompletten Schaltkreis, der Installationsmethode und den Bestimmungen des Bestimmungsmarktes ab.
Produktübersicht
CQC6 Series Industrial AC Contactor OEM Manufacturer is a AC contactor intended for remote switching and motor control. The current product record identifies it for motor starters, HVAC and automation panels. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.
Verified source summary: Type designation Dimensions (mm) Model number Amax Bmax Cmax Dmax a/a' b C Ф CQC6-06~25 46 76 83 117 35 50 60 Ф4.5 CQC6-32~38 57 85 96 130 40/43 48 / Ф4.5 CQC6-40~65 76 128 115 149 40/59 100 110 Ф5.5 CQC6-80~95 85 128 124 158 40/67 100 110 Ф5.5 Accessories Description Contact Configuration Technical Specifications Model number CQC6 -6 CQC6 -9 CQC6 -12 CQC6 -18 CQC6 -25 CQC6 -32 CQC6 -38 CQC6 -40 CQC6 -50 CQC6 -65 CQC
Hauptmerkmale
Typische Anwendungen
Typical use can include motor starters, HVAC and automation panels when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.
Antragsformular und Auswahlhinweis
Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.
| Auswahlpunkt | CQC6-Serie Industrielle AC-Schütze - OEM-Hersteller | Was das Projekt bestätigen muss |
|---|---|---|
| Anwendung | AC Contactor projects | Confirm the actual system and environment |
| Auswahlgrundlage | Fernschaltung und Motorsteuerung | Use the exact model and technical table |
| Installation | Follow the model instructions | Check mounting, clearances and termination |
| Compliance | Use the listed standard where applicable | Verify edition, scope and destination rules |
| Adjacent product | Evaluate the related CHAC family where function differs | Do not substitute without engineering review |
Funktion
Fernschaltung und Motorsteuerung
Match the protection or switching function to the system.
Konfiguration
Model-specific options
Confirm current, voltage, poles, terminals or accessories from the table.
Installation
Mechanical and electrical fit
Check enclosure, mounting, wiring space and maintenance access.
Project evidence
Documents and test records
Retain the approved drawing, technical sheet and commissioning record.
Anleitung zum Bestellen
- State the exact model and variant.
- Provide the system voltage, current, frequency and load or protection function.
- Confirm mounting, terminals, accessories, enclosure and environmental conditions.
- Share quantity, destination market and required technical documents.
Installations- und Koordinationskontrollen
- Verify the model’s ratings and connection arrangement against the project drawings.
- Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
- Coordinate upstream and downstream protection or control devices where applicable.
- Use qualified personnel for installation, testing, isolation and maintenance.
Typbezeichnung

Dimensions (mm)



| Model number | Amax | Bmax | Cmax | Dmax | a/a’ | b | C | Ф |
| CQC6-06~25 | 46 | 76 | 83 | 117 | 35 | 50 | 60 | Ф4.5 |
| CQC6-32~38 | 57 | 85 | 96 | 130 | 40/43 | 48 | / | Ф4.5 |
| CQC6-40~65 | 76 | 128 | 115 | 149 | 40/59 | 100 | 110 | Ф5.5 |
| CQC6-80~95 | 85 | 128 | 124 | 158 | 40/67 | 100 | 110 | Ф5.5 |
Accessories Description
Contact Configuration

Technische Spezifikationen
| Model number | CQC6 -6 |
CQC6 -9 |
CQC6 -12 |
CQC6 -18 |
CQC6 -25 |
CQC6 -32 |
CQC6 -38 |
CQC6 -40 |
CQC6 -50 |
CQC6 -65 |
CQC6 -80 |
CQC6 -95 |
|
| Rated insulation voltage (Ui) | 690V | ||||||||||||
| Rated impulse withstand voltage (Uimp) | 8kV | ||||||||||||
| Rated frequency | 50Hz, 50/60Hz | ||||||||||||
| Number of poles (P) | 3 | ||||||||||||
| Rated Operational Current (A)- AC-3 | 220V/230V | 6 | 9 | 12 | 18 | 25 | 32 | 38 | 40 | 50 | 65 | 80 | 95 |
| 380V/400V | 6 | 9 | 12 | 18 | 25 | 32 | 38 | 40 | 50 | 65 | 80 | 95 | |
| 660V/690V | 4.8 | 6.6 | 8.9 | 12 | 18 | 20.2 | 20.2 | 34 | 39 | 42 | 49 | 49 | |
| Conventional Free-Air Thermal Current (A) (AC-1, θ ≤ 60℃) | 20 | 25 | 25 | 32 | 40 | 50 | 50 | 60 | 80 | 80 | 110 | 110 | |
| Short-Time Withstand Current (A) | 10s | 80 | 105 | 105 | 145 | 145 | 260 | 310 | 320 | 400 | 520 | 640 | 800 |
| 1min | 45 | 61 | 61 | 84 | 84 | 138 | 150 | 165 | 208 | 260 | 320 | 400 | |
| 10min | 20 | 30 | 30 | 40 | 40 | 60 | 60 | 72 | 84 | 110 | 135 | 135 | |
| Controlled 3-Phase Squirrel Cage Motor Power (kW) – AC-3 | 220V/230V | 1.5 | 2 | 3.5 | 4 | 6 | 7.5 | 9 | 11 | 15 | 18.5 | 22 | 25 |
| 380V/400V | 2.2 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 18.5 | 22 | 30 | 37 | 45 | |
| 660V/690V | 3 | 5.5 | 7.5 | 10 | 15 | 18.5 | 18.5 | 30 | 33 | 37 | 45 | 45 | |
| Short-circuit protection by gG fuses (U ≤ 690V) for Type 2 coordination, without integral thermal overload relay | 20 | 25 | 25 | 32 | 40 | 50 | 50 | 60 | 80 | 80 | 110 | 110 | |
| Electrical Endurance (104 operations) | 120 | 100 | 80 | ||||||||||
| Rated Making Capacity (AC-3) | 10 × Ie, in accordance with IEC 60947-4-1 and GB/T 14048.4. | ||||||||||||
| Rated Breaking Capacity (AC-3) | 8 × Ie, in accordance with IEC 60947-4-1 and GB/T 14048.4. | ||||||||||||
| Characteristics of AC controlcircuits | |||||||||||||
| Operating Frequency (operations/h) | 1200 | 600 | |||||||||||
| Mechanical Life (104 operations, 3600 ops/h) | 1200 | 1000 | 800 | 600 | |||||||||
| AC Coil Power (50/60Hz) | Pick-up (VA) | 70 | 110 | 200 | 200 | ||||||||
| Sealed (VA) | 8 | 11 | 20 | 20 | |||||||||
| Operate Time (ms) | Close | 12-22 | 12-22 | 20-35 | 20-35 | ||||||||
| Open | 4-19 | 4-19 | 6-15 | 6-15 | |||||||||
| Operate Voltage Range (50/60Hz) | Pick-up Voltage: 80%Us ~ 110%Us; Drop-out Voltage: 20%Us ~ 75%Us | ||||||||||||
| Rated Control Supply Voltage Us | AC 24/36/48/110/220/230/380/400/415/440V, 50/60Hz | ||||||||||||
| Applicable accessories | Auxiliary contact block | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| Coil surge absorber | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| Main circuit conductor | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| Mechanical interlock | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| Mechano-electrical interlock | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| DIN rail mounting | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| Certifications obtained | CCC CE CB | ||||||||||||
Main Circuit Conductor (Busbar)
| Produkt Model |
Upper Conductor | Lower Conductor | Leitungsleiter | Applicable Models | ||||
| Amax | Bmax | Cmax | Amax | Bmax | Cmax | Dmax | ||
| F1-H1 | 88 | 24 | 28 | 88 | 17 | 28 | 2.5mm2 | CQC6-06/18 |
| F1-H2 | 103 | 29 | 33 | 103 | 20 | 35 | 6mm2 | CQC6-25/38 |
| F1-H3 | 134 | 43 | 55 | 134 | 30 | 50 | 10mm2 | CQC6-40/65 |
| F1-H4 | 150 | 52 | 51 | 150 | 37 | 50 | 16mm2 | CQC5-80/95 |

Electrical/Mechanical Interlock
| Product Name | Content | Product Model | Applicable Models | Wiring Diagram (ME) |
| Electrical Interlock | Electrical Interlock Kit | F2-LS3 | CQC6-06~38 | ![]() |
| Electrical Interlock Kit | F2-LS4 | CQC6-40-95 | ||
| Mechanical Interlock | Mechanical Interlock Kit | F2-LS1 | CQC6-06~38 | |
| Mechanical Interlock Kit | F2-LS2 | CQC6-40~95 |
Component size diagram (mm)

RC Snubber (Coil Surge Suppression)
| Product Model | Content | Applicable Models | Dimensions (mm) | |
| F3-LY2EA | AC 24…48V | CQC6-06~38 | ![]() |
![]() |
| F3-LY2GA | AC 50…127V | |||
| F3-LY2UA | AC 110…240V | |||
| F3-LY2NA | AC 380…415V | CQC6-40~95 | ||
| F3-LY2FC | AC 24…48V | |||
| F3-LY2GC | AC 50…127V | |||
| F3-LY2UC | AC 110…240V | ![]() |
||
| F3-LY2NC | AC 380…415V | |||
Hilfskontakte
| Product Name | Product Model | Content | Applicable Models | Dimensions (mm) | ||
| Top-Mounted Auxiliary (2 Contacts) |
F4-11 | 1NO + 1NC | CQC6-06~95 | ① | ![]() |
![]() |
| F4-20 | 2NO | |||||
| F4-02 | 2NC | |||||
| Top-Mounted Auxiliary (4 Contacts) |
F4-22 | 2NO + 2NC | ② | |||
| F4-40 | 4NO | |||||
| F4-04 | 4NC | |||||
| F4-13 | 1NO + 3NC | |||||
| F4-31 | 3NO + 1NC | |||||
| Elektrotechnische Parameter | |
| Conventional Thermal Current Ith | 10A |
| Rated Insulation Voltage Ui | 690V |
| Rated Impulse Withstand Voltage Uimp | 6kV |
| Minimum Switchable Load | 6V 100mA |
| Utilization Category | Rated Operational Voltage (V) | Rated Operational Current (A) |
| AC-15 | 380 | 0.95 |
| 220 | 1.6 | |
| DC-13 | 220 | 0.15 |
On-Delay Timer (Timer Head)
| Product Model | Content | Applicable Models |
| F5-T0 | 0.1…3s | CQC6-06-95 |
| F5-T2 | 0.1…30s | |
| F5-T4 | 10…180s | |
| F5-S2 | 1…30s | |
| F5-D0 | 0.1…3s | |
| F5-D2 | 0.1…30s | |
| F5-D4 | 10…180s |
Side-Mounted Auxiliary
| Product Model | Content | Applicable Models |
| F8-11 | 1NO + 1NC | CQC6-06-95 |
| F8-20 | 2NO | |
| F8-02 | 2NC |
Warum CHAC wählen?
Mit mehr als 30 Jahren Erfahrung in der Fertigung, 1100 Mitarbeitern und 100 Millionen Polen
Mit einer jährlichen Kapazität von 90% automatisierten Produktionslinien bietet CHAC eine stabile Produktionskapazität und strenge Qualitätskontrollen.
Qualitätskontrolle für globale OEM-/ODM-Kunden. Unser internes Fertigungssystem ermöglicht eine langfristige Zusammenarbeit.
Kooperation für Elektrohersteller, Importeure und Händler.

30+
JAHRE ERFAHRUNG
Specialisiert auf die Herstellung von Niederspannungselektronik

1100+
ARBEITER
Das professionelle Team gewährleistet eine stabile Qualität und Lieferfähigkeit.

100 Millionen+
JAHRESTERNE VON POLES
Großserienfertigung zur Deckung der weltweiten Nachfrage

90%
AUTOMATISCHE PRODUZIERUNG
Erweiterte Automatisierung für hohe Effizienz und Konsistenz

Automatisierte Montagelinie

Testlabor

Injektion und Stempeln

Qualitätskontrolle





Ein strenges Qualitätskontrollsystem gewährleistet, dass jedes Produkt den globalen Standards entspricht.
Was können wir anpassen?
CHAC supports customization of coil voltage, auxiliary contact configuration,
electrical parameters, product branding,packaging design and engineering development according to customers’ equipment and market requirements.
Spannung der Spule
Optionen für die Spannung der AC- und DC-Spulen, abgestimmt auf die Anforderungen der Anwendung.

Hilfskontakte
Flexibler Zusatzkontaktaufbau für verschiedene Steuerfunktionen.

Elektrotechnische Parameter
Die aktuellen Bewertungen, Schutzbereiche und Funktionsparameter können individuell angepasst werden.

Produktbranding
Unterstützung für private Etikettenlogos, Namensschilder und Produktidentifizierung.

Verpackungsdesign
Kundenspezifische Kartons, Etiketten, Handbücher und Verpackungslösungen.

Technisches Entwicklungsprogramm
Support von der Zeichnungserstellung über die Produktentwicklung bis hin zur passenden Anwendung.

Herunterladen
CQC6-Serie AC-Kontaktoren
Komplettes Produktüberblick für Niederspannungselektronikkomponenten und Referenz zur Produktauswahl.
Brauchen Sie technische Dokumente?
Kontaktieren Sie uns für Datenblätter, Zertifikate, Zeichnungen, Auswahlberatung oder Unterstützung bei OEM-/ODM-Projekten.
CQC6 Product FAQ
What loads can the CQC6 contactor switch?
Use the published utilization category, operational current and voltage for the selected variant. Resistive, motor and capacitive loads require different checks.
How do I select an AC contactor size?
Start with load current, utilization category, starts per hour, coil voltage, poles and short-circuit coordination. Current alone is not enough.
Can a thermal relay be paired with it?
Where the product record supports the combination, a thermal relay can form a motor starter. Confirm mechanical fit, current range and control wiring.
Which coil voltage should I specify?
Match the control supply shown on the project drawing with the coil option for the exact model. Never assume the coil voltage from the main circuit.
What accessories are available?
Auxiliary contacts, timers, interlocks or other accessories depend on the series and variant. Confirm the compatible accessory list before ordering.
How should a contactor be commissioned?
Verify terminal torque, coil voltage, contact sequence, insulation and operating current, then record the test results.
Confirm the Right CQC6 Configuration
Send the exact model, operating conditions, quantity, destination market and required documents. CHAC will review the request against the published product data.