Contactor de CC de alto voltaje serie STE2 (Sellado epoxi redondo)

El Contactor de CC de alto voltaje serie STE2 (Sellado epoxi redondo) is a CHAC high-voltage DC contactor for controlled DC switching and isolation. The page keeps the model-specific technical table and original product images so buyers can verify voltage, current, configuration, mounting and applicable standards before ordering. Final suitability depends on the complete circuit, installation method and destination-market rules.

Product family:
Contactor de CC de alto voltaje
Primary function:
controlled DC switching and isolation
Typical context:
battery, charging and high-voltage DC systems
Technical data:
See verified model table below
Configuration:
Confirm the exact model variant
Support:
OEM/ODM review available

Descripción del producto

STE2 Series High-voltage DC contactor (Round Epoxy Sealing) is a high-voltage DC contactor intended for controlled DC switching and isolation. The current product record identifies it for battery, charging and high-voltage DC systems. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.

Verified source summary: Type designation Product model Working voltage Working current Load polarity Coil polarity Auxiliary contact STE2-50 1500 50 Non-polarity Non-polarity / STE2-100 1500 100 Non-polarity Non-polarity / STE2-150 1500 150 Non-polarity Non-polarity / STE2-200 1500 200 Non-polarity Non-polarity 1NO STE2-250 1500 250 Non-polarity Non-polarity 1NO STE2-300 1500 300 Non-polarity Non-polarity 1NO STE2-400 1500 400 Non-polarity

Características clave

  • Product type: high-voltage DC contactor.
  • Primary function: controlled DC switching and isolation.
  • Application context: battery, charging and high-voltage DC systems.
  • Model variants, dimensions and ratings remain in the preserved technical source.
  • Confirm installation method, environmental limits and local compliance before release.

Aplicaciones típicas

Typical use can include battery, charging and high-voltage DC systems when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.

Guía de Solicitudes y Selección

Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.

Punto de selección Contactor de CC de alto voltaje serie STE2 (Sellado epoxi redondo) Lo que el proyecto debe confirmar
Solicitud High-Voltage DC Contactor projects Confirm the actual system and environment
Selection basis controlled DC switching and isolation Use the exact model and technical table
Instalación Follow the model instructions Check mounting, clearances and termination
Cumplimiento Use the listed standard where applicable Verify edition, scope and destination rules
Adjacent product Evaluate the related CHAC family where function differs Do not substitute without engineering review

Function

controlled DC switching and isolation

Match the protection or switching function to the system.

View related guidance →

Configuración

Model-specific options

Confirm current, voltage, poles, terminals or accessories from the table.

View related guidance →

Instalación

Mechanical and electrical fit

Check enclosure, mounting, wiring space and maintenance access.

View related guidance →

Project evidence

Documents and test records

Retain the approved drawing, technical sheet and commissioning record.

View related guidance →

Guía de pedidos

  1. State the exact model and variant.
  2. Provide the system voltage, current, frequency and load or protection function.
  3. Confirm mounting, terminals, accessories, enclosure and environmental conditions.
  4. Share quantity, destination market and required technical documents.

Comprobaciones de Instalación y Coordinación

  • Verify the model’s ratings and connection arrangement against the project drawings.
  • Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
  • Coordinate upstream and downstream protection or control devices where applicable.
  • Use qualified personnel for installation, testing, isolation and maintenance.

Designación del tipo

Modelo de producto Tensión de trabajo Corriente de trabajo Polaridad de carga Polaridad de la bobina Contacto auxiliar
STE2-50 1500 50 Apolaridad Apolaridad /
STE2-100 1500 100 Apolaridad Apolaridad /
STE2-150 1500 150 Apolaridad Apolaridad /
STE2-200 1500 200 Apolaridad Apolaridad 1NO
STE2-250 1500 250 Apolaridad Apolaridad 1NO
STE2-300 1500 300 Apolaridad Apolaridad 1NO
STE2-400 1500 400 Apolaridad Apolaridad 1NO
STE2-500 1500 500 Apolaridad Apolaridad 1NO
STE2-600 1500 600 Apolaridad Apolaridad 1NO
STE2-800 1000 800 Apolaridad Apolaridad 1NO

Especificaciones técnicas

Modelo de producto STE2-50 STE2-100
Formulario de contacto 1H 1H
Contacto auxiliar / NO
Polaridad de contacto Apolaridad Apolaridad
Resistencia de contacto ≤1mΩ(at 50A) ≤1 mΩ (a 100 A)
Tensión de funcionamiento ≤75%Un ≤75%Un
Corriente máxima de ruptura 50A 100A
Resistencia eléctrica 12~1500V 12~1500V
Corriente máxima de ruptura 500A(320V DC) 1000A(320V DC)
Resistencia eléctrica ≥1×10³ times(50A/750VDC)
≥400 times(20A/1000VDC)
≥150 times(10A/1500VDC)
≥2×10³ times(100A/750VDC)
≥1×10³ times(100A/1000VDC)
≥600 times(15A/1500VDC)
Transporte de corriente 50A: Continuo para
100A:10min 200A:50s
100A: Continuo para
150A:10min 300A:50s
Tensión soportada dieléctrica Entre contactos abiertos 3500VAC 3500VAC
Entre bobinas de contacto 3500VAC 3500VAC
Resistencia Mecánica 2×10⁵ veces 2×10⁵ veces
Voltaje de la bobina 12V, 24V 12V,24V,48V
Consumo de energía de la bobina 12V:5.5W 24V:6W 12V:5.5W 24V:6.0W
Método de extracción de carga Hilo interno Hilo interno
Método de salida de la bobina cable conductor cable conductor
Peso About 115g About 160g
Vibrar 80Hz~2000Hz 49m/s² 80Hz~2000Hz 49m/s²
Humedad 5%~95%RH 5%~95%RH
Rango de humedad -45℃~+85℃ -45℃~+85℃
Dimensiones externas (mm) 51.6×35.6×43.2 53.8×35.6×58.5

Nota:

1. Los parámetros anteriores son todos valores iniciales, medidos a una temperatura ambiente de 23 ℃.

2.Unless otherwise specified,the electrical durability tests are conducted on resistive loads with a on/off ratio of 0.6s:5s.

Modelo de producto STE2-150 STE2-200 STE2-250
Formulario de contacto 1H 1H 1H
Contacto auxiliar NO NO NO
Polaridad de contacto Apolaridad Apolaridad Apolaridad
Resistencia de contacto ≤1mΩ(at 150A) ≤1mΩ(at 200A) ≤1mΩ(at 250A)
Tensión de funcionamiento ≤75%Un ≤75%Un ≤75%Un
Corriente máxima de ruptura 150A 200A 250 A
Resistencia eléctrica 12~1500V 12~1500V 12~1500V
Corriente máxima de ruptura 1000A(320VDC) 2000A(320VDC) 2000A(320VDC)
Resistencia eléctrica ≥2×10³ times(100A/750VDC)
≥1×10³ times(150A/1000VDC)
≥600 times(30A/1500VDC)
≥2×10³ times(200A/750VDC)
≥1×10³ times(200A/1000VDC)
≥1×10³ times(50A/1500VDC)
≥2×10³ times(250A/750VDC)
≥1×10³ times(250A/1000VDC)
≥1×10³ times(50A/1500VDC)
Transporte de corriente 150A: Continuo por
180A:10min 300A:50s
200A: Continuo para
300A:10min 400A:180s
250A: Continuo para
300A:10min 400A:180s
Tensión soportada dieléctrica Entre contactos abiertos 3500VAC 3500VAC 3500VAC
Entre bobinas de contacto 3500VAC 3500VAC 3500VAC
Resistencia Mecánica 2×10⁵ veces 2×10⁵ veces 2×10⁵ veces
Voltaje de la bobina 12V,24V,36V,48V 12V,24V,36V,48V 12V,24V,36V,48V
Consumo de energía de la bobina 12V,24V,48V:5.76W 36V:2.5W 6W 6W
Método de extracción de carga Rosca externa Rosca externa Rosca externa
Método de salida de la bobina cable conductor cable conductor cable conductor
Peso About 430g About 430g About 430g
Vibrar 80Hz~2000Hz 49m/s² 80Hz~2000Hz 49m/s² 80Hz~2000Hz 49m/s²
Humedad 5%~95%RH 5%~95%RH 5%~95%RH
Rango de humedad -45℃~+85℃ -45℃~+85℃ -45℃~+85℃
Dimensiones externas (mm) 53.8×35.2×59.5 80.5×63.6×73.8 80.5×63.6×73.8

Nota:

1. Los parámetros anteriores son todos valores iniciales, medidos a una temperatura ambiente de 23 ℃.

2.Unless otherwise specified,the electrical durability tests are conducted on resistive loads with a on/off ratio of 0.6s:5s.

Modelo de producto STE2-300 STE2-400
Formulario de contacto 1H 1H
Contacto auxiliar NO NO
Polaridad de contacto Apolaridad Apolaridad
Resistencia de contacto ≤1mΩ(at 300A) ≤1mΩ(at 400A)
Tensión de funcionamiento ≤75%Un ≤75%Un
Corriente máxima de ruptura 300A 400A
Resistencia eléctrica 12~1500V 12~1500V
Corriente máxima de ruptura 2000A(320V DC) 2500A(320V DC)
Resistencia eléctrica ≥2×10³ times(300A/750VDC)
≥1×10³ times(300A/1000VDC)
≥1×10³ times(80A/1500VDC)
≥3×10³ times(400A/750VDC)
≥1×10³ veces (400A/1000VDC)
≥1×10³ times(200A/1500VDC)
Transporte de corriente 300A: Continuo durante
350A:10min 400A:180s
400A: Continuo durante
500A:10min 600A:180s
Tensión soportada dieléctrica Entre contactos abiertos 3500VAC 3500VAC
Entre bobinas de contacto 3500VAC 3500VAC
Resistencia Mecánica 2×10⁵ veces 2×10⁵ veces
Voltaje de la bobina 12V,24V,36V,48V 12V,24V,36V
Consumo de energía de la bobina 6W 3W
Método de extracción de carga Rosca externa Rosca externa
Método de salida de la bobina cable conductor cable conductor
Peso About 430g About 990g
Vibrar 80Hz~2000Hz 49m/s² 80Hz~2000Hz 49m/s²
Humedad 5%~95%RH 5%~95%RH
Rango de humedad -45℃~+85℃ -45℃~+85℃
Dimensiones externas (mm) 80.5×63.6×73.8 66.6×78.1×104.5

Nota:

1. Los parámetros anteriores son todos valores iniciales, medidos a una temperatura ambiente de 23 ℃.

2.Unless otherwise specified,the electrical durability tests are conducted on resistive loads with a on/off ratio of 0.6s:5s.

Modelo de producto STE2-500 STE2-600 STE2-800
Formulario de contacto 1H 1H 1H
Contacto auxiliar NO NO NO
Polaridad de contacto Apolaridad Apolaridad Apolaridad
Resistencia de contacto ≤1mΩ(at 500A) ≤1mΩ(at 600A) ≤1mΩ(at 800A)
Tensión de funcionamiento ≤75%Un ≤75%Un ≤75%Un
Corriente máxima de ruptura 500A 600A 800A
Resistencia eléctrica 12~1500V 12~1500V 12~1500V
Corriente máxima de ruptura 2500A(320VDC) 2500A(320V DC) 2500A(320V DC)
Resistencia eléctrica ≥2×10³ times(500A/750VDC)
≥1×10³ times(500A/1000VDC)
≥1×10³ times(250A/1500VDC)
≥2×10³ times(600A/750VDC)
≥1×10³ times(600A/1000VDC)
≥1×10³ times(300A/1500VDC)
≥600 times(800A/750VDC)
≥1×10³ times(450A/1000VDC)
≥200 times(350A/1500VDC)
Transporte de corriente 500A:Continuous for
550A:10min 600A:180s
600A: Continuo por
650A:10min 700A:180s
800A:Continuous for
900A:10min 1000A:120s
Tensión soportada dieléctrica Entre contactos abiertos 3500VAC 3500VAC 3500VAC
Entre bobinas de contacto 3500VAC 3500VAC 3500VAC
Resistencia Mecánica 2×10⁵ veces 2×10⁵ veces 2×10⁵ veces
Voltaje de la bobina 12V,24V,36V 12V,24V,36V 12V,24V,36V
Consumo de energía de la bobina 3W 3W 3W
Método de extracción de carga Rosca externa Rosca externa Rosca externa
Método de salida de la bobina cable conductor cable conductor cable conductor
Peso About 990g About 990g About 990g
Vibrar 80Hz~2000Hz 49m/s² 80Hz~2000Hz 49m/s² 80Hz~2000Hz 49m/s²
Humedad 5%~95%RH 5%~95%RH 5%~95%RH
Rango de humedad -45℃~+85℃ -45℃~+85℃ -45℃~+85℃
Dimensiones externas (mm) 66.6×78.1×104.5 66.6×78.1×104.5 66.6×78.1×104.5

Nota:

1. Los parámetros anteriores son todos valores iniciales, medidos a una temperatura ambiente de 23 ℃.

2.Unless otherwise specified,the electrical durability tests are conducted on resistive loads with a on/off ratio of 0.6s:5s.

¿Por qué elegir CHAC?

Con más de 30 años de experiencia en fabricación, más de 1100 empleados, más de 100 millones de postes
Con una capacidad anual y un proceso de producción automatizado 90%, CHAC ofrece una capacidad de producción estable y un estricto
control de calidad para clientes OEM/ODM globales. Nuestro sistema de fabricación interno respalda a largo plazo
Cooperación para marcas eléctricas, importadores y distribuidores.


30+

AÑOS DE EXPERIENCIA

Especializado en fabricación eléctrica de bajo voltaje


1100+

EMPLEADOS

Equipo profesional garantiza calidad y entrega estables


100M+

CAPACIDAD ANUAL DE LOS POLOS

Capacidad de producción a gran escala para satisfacer la demanda mundial


90%

PRODUCCIÓN AUTOMATIZADA

Automatización avanzada para alta eficiencia y consistencia

Línea de ensamblaje automatizada

Línea de ensamblaje automatizada

Laboratorio de pruebas

Laboratorio de pruebas

Inyección y Estampado

Inyección y Estampado

Inspección de calidad

Inspección de calidad

Certificación IEC
Certificación CE
Certificación CB
Certificación RoHS
Certificación ISO 14001

Un estricto sistema de control de calidad garantiza que cada producto cumpla con los estándares mundiales.

¿Qué podemos personalizar?

CHAC admite la personalización del voltaje de la bobina y la configuración de los contactos auxiliares.,
parámetros eléctricos, marca del producto, diseño de envasado y desarrollo de ingeniería según los equipos y requisitos de mercado de los clientes.

Voltaje de la bobina

Voltaje de la bobina

Opciones de voltaje de bobina de CA y CC adaptadas a los requisitos de la aplicación.

Personalización del voltaje de la bobina para opciones de voltaje de bobina de CA y CC
Contactos Auxiliares

Contactos Auxiliares

Combinaciones flexibles de contactos auxiliares para diferentes funciones de control.

Personalización de contactos auxiliares para diferentes funciones de control
Parámetros eléctricos

Parámetros eléctricos

Las clasificaciones actuales, los rangos de protección y los parámetros funcionales se pueden personalizar.

Personalización de parámetros eléctricos para rangos de corriente y protección
Marca de producto

Marca de producto

Logotipos de marca privada, placas de identificación y soporte para la identificación de productos.

Personalización de marca de producto que incluye logotipos de marca privada y placas de identificación
Diseño de empaque

Diseño de empaque

Soluciones de embalaje, cajas personalizadas, etiquetas y manuales.

Diseño de empaque personalizable, incluyendo cajas, etiquetas, manuales y soluciones de empaque.
Desarrollo de Ingeniería

Desarrollo de Ingeniería

Soporte desde la optimización de dibujos hasta el desarrollo de productos y la adaptación de aplicaciones.

Soporte de desarrollo de ingeniería desde la optimización de dibujos hasta el desarrollo de productos

Descargar

PDF

Contactor de CC de alto voltaje serie STE

Descripción general completa de componentes eléctricos de bajo voltaje y referencia para la selección de productos.

 

Arriba

¿Necesita documentos técnicos?

Contáctenos para obtener hojas de datos, certificados, planos, orientación de selección o soporte para proyectos OEM/ODM.

Contáctanos

STE2 Product FAQ

What is the STE2 used for?

It is a high-voltage DC switching device for the system and variant shown in the technical table. Confirm the working voltage, current, polarity and load category.

Why does DC contactor polarity matter?

Some variants specify load or coil polarity because DC arc management and magnetic blowout depend on the internal design. Follow the marked polarity.

How do I select the voltage and current?

Use the actual steady, inrush and breaking current, system voltage, duty cycle and fault-clearing strategy. The family range is not a blanket rating for every variant.

What does ceramic or epoxy sealing change?

The sealing construction is part of the product design and environmental suitability. Compare the exact datasheet for temperature, insulation and endurance.

Can it switch a battery or charger circuit?

It may be suitable when the variant's DC voltage, current, breaking duty and insulation data match the application. Confirm the complete design.

What should be tested before energizing?

Check coil operation, contact resistance, insulation, polarity, pre-charge or discharge sequence and the emergency isolation procedure.

Confirm the Right STE2 Configuration

Send the exact model, operating conditions, quantity, destination market and required documents. CHAC will review the request against the published product data.

Solicitar un presupuesto