Термореле серии CQR2
The Термореле серии CQR2 is a CHAC thermal overload relay for adjustable motor overload protection. The page keeps the model-specific technical table and original product images so buyers can verify voltage, current, configuration, mounting and applicable standards before ordering. Final suitability depends on the complete circuit, installation method and destination-market rules.
Обзор продукции
CQR2 Series Thermal overload relay is a thermal overload relay intended for adjustable motor overload protection. The current product record identifies it for motor starters, fans and pump control. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.
Verified source summary: Type designation Selection Guide Instructions for Use CQR2 Series Thermal Overload Relay Panel Symbols and Functional Button Description Trip Test (Performed BEFORE energizing the main circuit): Open the cover. Press the test button with a screwdriver. The NC contacts will open and the NO contacts will close. The status change can be observed through the indicator window (yellow mark visible indicates tripped state;
Основные особенности
Типичные применения
Typical use can include motor starters, fans and pump control when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.
Приложение и руководство по отбору
Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.
| Точка отбора | Термореле серии CQR2 | Что должно подтвердить проект |
|---|---|---|
| Приложение | Thermal Relay projects | Confirm the actual system and environment |
| Selection basis | adjustable motor overload protection | Use the exact model and technical table |
| Installation | Follow the model instructions | Check mounting, clearances and termination |
| Соблюдение требований | Use the listed standard where applicable | Verify edition, scope and destination rules |
| Adjacent product | Evaluate the related CHAC family where function differs | Do not substitute without engineering review |
Функция
adjustable motor overload protection
Match the protection or switching function to the system.
Конфигурация
Model-specific options
Confirm current, voltage, poles, terminals or accessories from the table.
Installation
Mechanical and electrical fit
Check enclosure, mounting, wiring space and maintenance access.
Project evidence
Documents and test records
Retain the approved drawing, technical sheet and commissioning record.
Руководство по оформлению заказа
- State the exact model and variant.
- Provide the system voltage, current, frequency and load or protection function.
- Confirm mounting, terminals, accessories, enclosure and environmental conditions.
- Share quantity, destination market and required technical documents.
Проверки установки и координации
- Verify the model’s ratings and connection arrangement against the project drawings.
- Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
- Coordinate upstream and downstream protection or control devices where applicable.
- Use qualified personnel for installation, testing, isolation and maintenance.
Тип обозначения

Selection Guide

Instructions for Use
CQR2 Series Thermal Overload Relay Panel Symbols and Functional Button Description

Trip Test (Performed BEFORE energizing the main circuit):
Open the cover. Press the test button with a screwdriver. The NC contacts will open and the NO contacts will close. The status change can be observed through the indicator window (yellow mark visible indicates tripped state; mark hidden indicates reset state – see illustration above).
Reset Mode Setting (Performed BEFORE energizing the main circuit):
The relay leaves the factory set to manual reset mode. To select automatic reset mode, press and hold the reset button while turning it clockwise 90°. It is not advisable to change the reset mode while the circuit is energized and running.
Setting Current Adjustment (Performed BEFORE energizing the main circuit):
The relay leaves the factory set to the minimum setting current. To select a different setting current value, open the cover and turn the current setting dial with a screwdriver. Align the arrow on the dial with the current value corresponding to the full-load rated current of the motor being protected.
Emergency Stop:
Press the Stop Button. Pressing the stop button only opens the NC contacts; it does not affect the NO contacts. Releasing the stop button resets the NC contacts.
Dimensions (mm)
CQR2-25

CQR2-38

CQR2-95

Технические характеристики
| Product Model | CQR2-25 | CQR2-38 | CQR2-95 | ||
| Current rating | 25 | 38 | 95 | ||
| Rated insulation voltage V | 690 | 690 | 690 | ||
| Rated impulse withstand voltage V | 6000 | 6000 | 6000 | ||
| Enclosure protection grade | IP20(Front side) | IP20(Front side) | IP20(Front side) | ||
| Phase loss protection | ● | ● | ● | ||
| Manual and automatic reset | ● | ● | ● | ||
| Temperature compensation | ● | ● | ● | ||
| Tripping indication | ● | ● | ● | ||
| Test button | ● | ● | ● | ||
| Stop button | ● | ● | ● | ||
| Installation method | Insertable | Insertable | Insertable | ||
| Auxiliary contact | 1NO+1NC | 1NO+1NC | 1NO+1NC | ||
| AC-15220V rated current A | 2.73 | 2.73 | 2.73 | ||
| AC-15380V rated current A | 1.58 | 1.58 | 1.58 | ||
| DC-13220V rated current A | 0.2 | 0.2 | 0.2 | ||
| Cross-sectional area of conductor(mm²) | Main circuit | Single-core or stranded wire | 1 ~ 4 | 6~10 | 6~35 |
| Wire connection screw | M4 | M4 | M10 | ||
| Auxiliary circuit | Single-core or stranded wire | 1 ~ 2.5 | 1~2.5 | 1-2.5 | |
| Wire connection screw | M3.5 | M3.5 | M3.5 | ||
Tripping Characteristics
| Товар | No. | Setting Current Multiple | Operating Time | Purpose / Test Condition | |
| Overload Protection | 1 | 1.05 | No operation within 2 hours | Starting from Cold State | |
| 2 | 1.2 | Operation within 2 hours | Starting from Hot State (after Item 1) | ||
| 3 | 1.5 | Operation within 2 minutes | Starting after reaching thermal equilibrium at setting current | ||
| 4 | 7.2 | 2S<TP≤10S | Starting from Cold State | ||
| Phase Failure Protection | 5 | Any Two Phases | One Phase | No operation within 2 hours | Starting from Cold State |
| 1 | 0.9 | ||||
| 6 | 1.15 | 0 | Operation within 2 hours | Starting from Hot State (after Item 5) | |
Adjustable Trip Setting Range
| Product Model | Current adjustment range RC(A) | Plug-in contactors | Short-circuit protection fuse (A) | |
| aM | gG | |||
| CQR2-25 | 0.1~0.16 | CQC6(SM/KMNC1)-09 CQC6(SM/KMNC1)-12 CQC6(SM/KMNC1)-18 CQC6(SM/KMNC1)-25 |
0.25 | 2 |
| 0.16~0.25 | 0.5 | 2 | ||
| 0.25~0.40 | 1 | 2 | ||
| 0.40~0.63 | 1 | 2 | ||
| 0.63~1 | 2 | 4 | ||
| 1~1.6 | 2 | 4 | ||
| 1.6~2.5 | 4 | 6 | ||
| 2.5~4 | 6 | 10 | ||
| 4~6 | 8 | 16 | ||
| 5.5-8 | 12 | 20 | ||
| 7~10 | 12 | 20 | ||
| 9~13 | 16 | 25 | ||
| 12~18 | 20 | 35 | ||
| 17-25 | 25 | 50 | ||
| CQR2-38 | 23-32 | CQC6(SM/KMNC1)-32 | 40 | 63 |
| 30~38 | 40 | 80 | ||
| CQR2-95 | 17~25 | CQC6(SM/KMNC1)-40 CQC6(SM/KMNC1)-50 CQC6(SM/KMNC1)-65 CQC6(SM/KMNC1)-80 CQC6(SM/KMNC1)-95 |
25 | 50 |
| 23~32 | 40 | 63 | ||
| 30~40 | 40 | 100 | ||
| 37~50 | 63 | 100 | ||
| 48~65 | 63 | 100 | ||
| 55~70 | 80 | 125 | ||
| 63~85 | 80 | 125 | ||
| 80~95 | 100 | 160 | ||
Accessories Description
| Приложение | Model number | Приложение |
| MB-1 | Combined with M12 to form an independent mounting product | |
![]() |
MB-2 | Combined with M25 to form an independent mounting product |
![]() |
MB-3 | Combined with M38 to form an independent mounting product |
![]() |
MB-4 | Combined with M95 to form an independent mounting product |
Почему стоит выбрать CHAC
С более чем 30-летним опытом производства, 1100 сотрудниками и 100 млн полюсов
Ежегодный производственный потенциал и 90% автоматизированных производственных линий обеспечивают стабильный производственный потенциал и строгий контроль качества.
контроль качества для глобальных клиентов из категории OEM/ODM. Наша собственная система производства обеспечивает долгосрочную стабильность
сотрудничество с производителями электротоваров, импортерами и дистрибьюторами.
30+
МЫСЛИ О ВРЕМЕНИ
Специализируется на производстве электрооборудования низкого напряжения
1100+
Сотрудники
Профессиональная команда обеспечивает стабильное качество и своевременную поставку
100 миллионов+
ГОДИЧЕСКИЙ КОМПАКТ ПОЛОВ
Большой производственный потенциал для удовлетворения мирового спроса
90%
Автоматизированное производство
Передовая автоматизация для высокой эффективности и стабильности

Автоматизированная производственная линия

Лаборатория тестирования

Инъекция и литье

Проверка качества





Строгое система контроля качества гарантирует, что каждый продукт соответствует мировым стандартам.
Что мы можем настроить?
CHAC supports customization of coil voltage, auxiliary contact configuration,
electrical parameters, product branding,packaging design and engineering development according to customers’ equipment and market requirements.
Напряжение на катушке
Варианты напряжения для роторных и постоянных магнитных роторов, адаптированные под требования конкретного применения.

Дополнительные контакты
Гибкие комбинации вспомогательных контактов для различных функций управления.

Электрические параметры
Текущие характеристики, диапазоны защиты и функциональные параметры могут быть настроены по желанию заказчика.

Брендность продукции
Поддержка использования фирменных логотипов, табличек с названием и идентификации продукции.

Дизайн упаковки
Наборы из картонных коробок, этикетки, инструкции и решения по упаковке.

Разработка инженерных решений
Поддержка от оптимизации чертежей до разработки продукции и подбора приложений.

Скачать
Термореле CQR2 серии
Полный обзор продукции электрооборудования низкого напряжения и справочник по выбору продукции.
Нужен технический документ?
Для получения информационных листовок, сертификатов, чертежей, рекомендаций по выбору или поддержки проектов OEM/ODM обращайтесь к нам.
CQR2 Product FAQ
What does the CQR2 protect?
It provides adjustable thermal overload protection for compatible AC motor starters. It is not a replacement for short-circuit protection.
How do I choose the relay range?
Select a range that contains the motor's rated current, then set it from the nameplate and installation conditions.
What is manual versus automatic reset?
Manual reset requires an intentional reset after a trip. Automatic reset can restart the control sequence when permitted by the machine risk assessment.
Does it detect phase failure?
The product record includes phase-failure protection. Confirm the exact variant, motor connection and test procedure.
Can it connect to a CQC6 contactor?
The page identifies CQC6 integration as an application. Confirm the mechanical interface and current range for the selected combination.
What should be recorded after testing?
Record the set current, trip test result, reset mode, auxiliary-contact operation and responsible technician.
Confirm the Right CQR2 Configuration