مصنع OEM لموصلات التيار المتردد الصناعية من سلسلة CQC6

ال مصنع OEM لموصلات التيار المتردد الصناعية من سلسلة CQC6 is a CHAC AC contactor for remote switching and motor control. The page keeps the model-specific technical table and original product images so buyers can verify voltage, current, configuration, mounting and applicable standards before ordering. Final suitability depends on the complete circuit, installation method and destination-market rules.

Product family:
مُلامِس تكييف
Primary function:
remote switching and motor control
Typical context:
motor starters, HVAC and automation panels
Technical data:
See verified model table below
Configuration:
Confirm the exact model variant
Support:
OEM/ODM review available

Product Overview

CQC6 Series Industrial AC Contactor OEM Manufacturer is a AC contactor intended for remote switching and motor control. The current product record identifies it for motor starters, HVAC and automation panels. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.

Verified source summary: Type designation Dimensions (mm) Model number Amax Bmax Cmax Dmax a/a' b C Ф CQC6-06~25 46 76 83 117 35 50 60 Ф4.5 CQC6-32~38 57 85 96 130 40/43 48 / Ф4.5 CQC6-40~65 76 128 115 149 40/59 100 110 Ф5.5 CQC6-80~95 85 128 124 158 40/67 100 110 Ф5.5 Accessories Description Contact Configuration Technical Specifications Model number CQC6 -6 CQC6 -9 CQC6 -12 CQC6 -18 CQC6 -25 CQC6 -32 CQC6 -38 CQC6 -40 CQC6 -50 CQC6 -65 CQC

Key Features

  • Product type: AC contactor.
  • Primary function: remote switching and motor control.
  • Application context: motor starters, HVAC and automation panels.
  • Model variants, dimensions and ratings remain in the preserved technical source.
  • Confirm installation method, environmental limits and local compliance before release.

Typical Applications

Typical use can include motor starters, HVAC and automation panels when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.

Applications and Selection Guide

Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.

Selection point مصنع OEM لموصلات التيار المتردد الصناعية من سلسلة CQC6 What the project must confirm
تطبيق AC Contactor projects Confirm the actual system and environment
Selection basis remote switching and motor control Use the exact model and technical table
Installation Follow the model instructions Check mounting, clearances and termination
Compliance Use the listed standard where applicable Verify edition, scope and destination rules
Adjacent product Evaluate the related CHAC family where function differs Do not substitute without engineering review

Function

remote switching and motor control

Match the protection or switching function to the system.

View related guidance →

إعدادات

Model-specific options

Confirm current, voltage, poles, terminals or accessories from the table.

View related guidance →

Installation

Mechanical and electrical fit

Check enclosure, mounting, wiring space and maintenance access.

View related guidance →

Project evidence

Documents and test records

Retain the approved drawing, technical sheet and commissioning record.

View related guidance →

Ordering Guide

  1. State the exact model and variant.
  2. Provide the system voltage, current, frequency and load or protection function.
  3. Confirm mounting, terminals, accessories, enclosure and environmental conditions.
  4. Share quantity, destination market and required technical documents.

Installation and Coordination Checks

  • Verify the model’s ratings and connection arrangement against the project drawings.
  • Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
  • Coordinate upstream and downstream protection or control devices where applicable.
  • Use qualified personnel for installation, testing, isolation and maintenance.

تعيين النوع

الأبعاد (مم)

Model number Amax Bmax Cmax Dmax a/a’ b C Ф
CQC6-06~25 46 76 83 117 35 50 60 Ф4.5
CQC6-32~38 57 85 96 130 40/43 48 / Ф4.5
CQC6-40~65 76 128 115 149 40/59 100 110 Ф5.5
CQC6-80~95 85 128 124 158 40/67 100 110 Ф5.5

Accessories Description

Contact Configuration

المواصفات الفنية

Model number CQC6
-6
CQC6
-9
CQC6
-12
CQC6
-18
CQC6
-25
CQC6
-32
CQC6
-38
CQC6
-40
CQC6
-50
CQC6
-65
CQC6
-80
CQC6
-95
Rated insulation voltage (Ui) 690V
جهد التحمل نبضي المقنن 8kV
التردد المقدر 50Hz, 50/60Hz
Number of poles (P) 3
Rated Operational Current (A)- AC-3 220V/230V 6 9 12 18 25 32 38 40 50 65 80 95
380V/400V 6 9 12 18 25 32 38 40 50 65 80 95
660V/690V 4.8 6.6 8.9 12 18 20.2 20.2 34 39 42 49 49
Conventional Free-Air Thermal Current (A) (AC-1, θ ≤ 60℃) 20 25 25 32 40 50 50 60 80 80 110 110
Short-Time Withstand Current (A) 10s 80 105 105 145 145 260 310 320 400 520 640 800
1min 45 61 61 84 84 138 150 165 208 260 320 400
10min 20 30 30 40 40 60 60 72 84 110 135 135
Controlled 3-Phase Squirrel Cage Motor Power (kW) – AC-3 220V/230V 1.5 2 3.5 4 6 7.5 9 11 15 18.5 22 25
380V/400V 2.2 4 5.5 7.5 11 15 18.5 18.5 22 30 37 45
660V/690V 3 5.5 7.5 10 15 18.5 18.5 30 33 37 45 45
Short-circuit protection by gG fuses (U ≤ 690V) for Type 2 coordination, without integral thermal overload relay 20 25 25 32 40 50 50 60 80 80 110 110
Electrical Endurance (104 operations) 120 100 80
Rated Making Capacity (AC-3) 10 × Ie, in accordance with IEC 60947-4-1 and GB/T 14048.4.
Rated Breaking Capacity (AC-3) 8 × Ie, in accordance with IEC 60947-4-1 and GB/T 14048.4.
Characteristics of AC controlcircuits
Operating Frequency (operations/h) 1200 600
Mechanical Life (104 operations, 3600 ops/h) 1200 1000 800 600
AC Coil Power (50/60Hz) Pick-up (VA) 70 110 200 200
Sealed (VA) 8 11 20 20
Operate Time (ms) Close 12-22 12-22 20-35 20-35
Open 4-19 4-19 6-15 6-15
Operate Voltage Range (50/60Hz) Pick-up Voltage: 80%Us ~ 110%Us; Drop-out Voltage: 20%Us ~ 75%Us
Rated Control Supply Voltage Us AC 24/36/48/110/220/230/380/400/415/440V, 50/60Hz
Applicable accessories Auxiliary contact block
Coil surge absorber
Main circuit conductor
Mechanical interlock
Mechano-electrical interlock
DIN rail mounting
Certifications obtained CCC CE CB

Main Circuit Conductor (Busbar)

منتج
نموذج
Upper Conductor Lower Conductor Conductor Applicable Models
Amax Bmax Cmax Amax Bmax Cmax Dmax
F1-H1 88 24 28 88 17 28 2.5mm2 CQC6-06/18
F1-H2 103 29 33 103 20 35 6mm2 CQC6-25/38
F1-H3 134 43 55 134 30 50 10mm2 CQC6-40/65
F1-H4 150 52 51 150 37 50 ١٦ مم2 CQC5-80/95

Electrical/Mechanical Interlock

Product Name Content طراز المنتج Applicable Models Wiring Diagram (ME)
Electrical Interlock Electrical Interlock Kit F2-LS3 CQC6-06~38
Electrical Interlock Kit F2-LS4 CQC6-40-95
Mechanical Interlock Mechanical Interlock Kit F2-LS1 CQC6-06~38
Mechanical Interlock Kit F2-LS2 CQC6-40~95

Component size diagram (mm)

RC Snubber (Coil Surge Suppression)

طراز المنتج Content Applicable Models الأبعاد (مم)
F3-LY2EA AC 24…48V CQC6-06~38
F3-LY2GA AC 50…127V
F3-LY2UA AC 110…240V
F3-LY2NA AC 380…415V CQC6-40~95
F3-LY2FC AC 24…48V
F3-LY2GC AC 50…127V
F3-LY2UC AC 110…240V
F3-LY2NC AC 380…415V

ملامسات مساعدة

Product Name طراز المنتج Content Applicable Models الأبعاد (مم)
Top-Mounted Auxiliary
(2 Contacts)
F4-11 1NO + 1NC CQC6-06~95
F4-20 2NO
F4-02 2NC
Top-Mounted Auxiliary
(4 Contacts)
F4-22 2NO + 2NC
F4-40 4NO
F4-04 4NC
F4-13 1NO + 3NC
F4-31 3NO + 1NC
المعاملات الكهربائية
Conventional Thermal Current Ith 10A
Rated Insulation Voltage Ui 690V
Rated Impulse Withstand Voltage Uimp 6kV
Minimum Switchable Load 6V 100mA
Utilization Category Rated Operational Voltage (V) Rated Operational Current (A)
AC-15 380 0.95
220 1.6
DC-13 220 0.15

On-Delay Timer (Timer Head)

طراز المنتج Content Applicable Models
F5-T0 0.1…3s CQC6-06-95
F5-T2 0.1…30s
F5-T4 10…180s
F5-S2 1…30s
F5-D0 0.1…3s
F5-D2 0.1…30s
F5-D4 10…180s

Side-Mounted Auxiliary

طراز المنتج Content Applicable Models
F8-11 1NO + 1NC CQC6-06-95
F8-20 2NO
F8-02 2NC

لماذا تختار CHAC

مع خبرة تصنيع تزيد عن 30 عامًا، وأكثر من 1100 موظف، وأكثر من 100 مليون عمود
بفضل طاقتها الإنتاجية السنوية ونظام الإنتاج الآلي 90%، توفر شركة CHAC طاقة إنتاجية مستقرة ومعايير صارمة
مراقبة الجودة لعملاء OEM/ODM العالميين. يدعم نظام التصنيع الداخلي الخاص بنا على المدى الطويل
تعاون مع العلامات التجارية الكهربائية والمستوردين والموزعين.


30+

سنوات الخبرة

متخصص في تصنيع المعدات الكهربائية منخفضة الجهد


1100+

الموظفين

فريق محترف يضمن جودة ثابتة والتسليم


١٠٠ مليون+

السعة السنوية للأعمدة

قدرة إنتاجية واسعة النطاق لتلبية الطلب العالمي


90%

الإنتاج الآلي

الأتمتة المتقدمة لتحقيق كفاءة واتساق عاليين

خط التجميع الآلي

خط التجميع الآلي

مختبر اختبار

مختبر اختبار

حقن وختم

حقن وختم

فحص الجودة

فحص الجودة

شهادة IEC
شهادة CE
شهادة CB
شهادة RoHS
شهادة الآيزو 14001

نظام صارم لمراقبة الجودة يضمن أن كل منتج يلبي المعايير العالمية.

ما الذي يمكننا تخصيصه؟

تدعم تشاك تخصيص جهد الملف وتكوين نقاط التلامس المساعدة،,
المعلمات الكهربائية، والعلامة التجارية للمنتج، وتصميم التعبئة والتغليف، والتطوير الهندسي وفقاً لمعدات العملاء ومتطلبات السوق.

جهد الملف

جهد الملف

خيارات جهد ملف التيار المتردد وتيار مستمر مصممة لتناسب متطلبات التطبيق.

تخصيص جهد الملف لخيارات جهد الملف للتيار المتردد والمستمر
ملامسات مساعدة

ملامسات مساعدة

مجموعات اتصالات مساعدة مرنة لوظائف تحكم مختلفة.

تخصيص الملامسات المساعدة لوظائف التحكم المختلفة
المعاملات الكهربائية

المعاملات الكهربائية

يمكن تخصيص التصنيفات الحالية، ونطاقات الحماية، والمعلمات الوظيفية.

تخصيص المعلمات الكهربائية لتصنيفات التيار ونطاقات الحماية
علامة تجارية للمنتج

علامة تجارية للمنتج

شعارات الملصقات الخاصة، ولوحات الأسماء، ودعم تعريف المنتج.

تخصيص العلامة التجارية للمنتج بما في ذلك شعارات الملصقات الخاصة ولوحات الأسماء
تصميم عبوات

تصميم عبوات

علب مخصصة، وملصقات، وأدلة، وحلول تغليف.

تصميم تغليف مخصص يشمل علب، ملصقات، كتيبات، وحلول تغليف
التطوير الهندسي

التطوير الهندسي

الدعم من تحسين الرسم إلى تطوير المنتج وتطابق التطبيقات.

دعم التطوير الهندسي من تحسين الرسومات إلى تطوير المنتج

تنزيل

ملف PDF

مُوصّل CQC6 AC

نظرة عامة كاملة على مكونات كهربائية منخفضة الجهد ومرجع لاختيار المنتج.

تحميل ملف PDF

سوب

هل تحتاج إلى وثائق فنية؟

اتصل بنا للحصول على أوراق البيانات، والشهادات، والرسومات، وإرشادات الاختيار، أو دعم مشاريع OEM/ODM.

اتصل بنا

CQC6 Product FAQ

What loads can the CQC6 contactor switch?

Use the published utilization category, operational current and voltage for the selected variant. Resistive, motor and capacitive loads require different checks.

How do I select an AC contactor size?

Start with load current, utilization category, starts per hour, coil voltage, poles and short-circuit coordination. Current alone is not enough.

Can a thermal relay be paired with it?

Where the product record supports the combination, a thermal relay can form a motor starter. Confirm mechanical fit, current range and control wiring.

Which coil voltage should I specify?

Match the control supply shown on the project drawing with the coil option for the exact model. Never assume the coil voltage from the main circuit.

What accessories are available?

Auxiliary contacts, timers, interlocks or other accessories depend on the series and variant. Confirm the compatible accessory list before ordering.

How should a contactor be commissioned?

Verify terminal torque, coil voltage, contact sequence, insulation and operating current, then record the test results.

Confirm the Right CQC6 Configuration

Send the exact model, operating conditions, quantity, destination market and required documents. CHAC will review the request against the published product data.

Request a Quote