CQB7ZNM-80 WIFI Circuit Breaker Smart Circuit Breaker

The CQB7ZNM-80 is specified for overload, short-circuit, leakage and voltage monitoring functions. Select it using the published voltage, current, pole and protection data, then confirm conductor coordination, fault conditions, enclosure requirements and local installation rules.

Poles:
1P+N
Rated Current:
32–80A
Rated Voltage:
230/240V AC
Primary Function:
overload, short-circuit, leakage and voltage monitoring functions
Selection Data:
C curve; AC residual-current type listed
Standard:
IEC 61009-1 and IEC 60898-1 references

Product Overview

CQB7ZNM-80 is a WiFi smart circuit breaker for 230/240V AC applications. It is intended for connected residential or light-commercial circuits where local protection remains independent of the app; this describes an evaluation context, not a universal approval. Confirm the complete circuit design before specifying the product.

overload, short-circuit, leakage and voltage monitoring functions is distinct from adjacent protection functions. Do not infer AC/DC suitability, residual-current protection, automatic control or isolation performance from the product family name alone.

Key Features

  • Published pole options: 1P+N.
  • Published electrical context: 230/240V AC.
  • Primary function: overload, short-circuit, leakage and voltage monitoring functions.
  • Selection reference: C curve; AC residual-current type listed.
  • Applicable standard reference: IEC 61009-1 and IEC 60898-1 references.
  • Final selection must use the exact model table, drawings and installation instructions.

Typical Applications

connected residential or light-commercial circuits where local protection remains independent of the app. Verify system voltage, expected fault current or leakage, wiring arrangement, environment, coordination and applicable rules for the ordered configuration.

Applications and Selection Guide

Use the verified CQB7ZNM-80 records below to create a shortlist. Product labels do not replace the project calculation, coordination review or exact installation instructions.

Selection point CQB7ZNM-80 reference What the project must confirm
Rated current Use the exact model table Design current, conductor capacity, ambient and grouping
Voltage and frequency 230/240V AC Supply system and equipment rating
Poles 1P+N Conductors to be switched, protected or isolated
Protection / control overload, short-circuit, leakage and voltage monitoring functions Required function and adjacent-device coordination
Fault / residual data C curve; AC residual-current type listed Prospective short-circuit or leakage conditions

Local Protection and Smart Control

Remote monitoring or automatic control does not replace local protection, isolation and commissioning procedures. Verify network, control and fallback behaviour.

Control Architecture
Request Technical Support →

Model-Specific Ratings

Use the exact technical table for rated voltage, current, poles, terminals, life and environmental limits.

Verified Data
View Technical Support →

Installation and Coordination

Check the complete circuit, conductor sizing, fault or leakage conditions, enclosure and local rules before energising.

Engineering Check
Discuss a Configuration →

Ordering Information

State model, rating, poles, system, quantity, destination market and document requirements so the configuration can be reviewed.

Project Inputs
Send Project Details →

Ordering Guide

  1. State the exact model: CQB7ZNM-80.
  2. Provide rated current and voltage from the published technical table.
  3. Confirm poles and the required protection, isolation or control function.
  4. Provide application, expected fault/leakage conditions, destination market and quantity.
  5. List accessory, terminal, documentation and approved marking or packaging requirements.

Installation and Coordination Checks

  • Use the exact model drawing and instructions; do not infer wiring or accessory compatibility from another product.
  • Verify conductor size, terminal torque, enclosure conditions, temperature, grouping and clearances.
  • Coordinate upstream and downstream devices and confirm the required fault, leakage or voltage response.
  • Installation, testing and maintenance must be completed by qualified personnel under applicable rules.

Type designation

Tripping curves

Dimensions(mm)

Technical Specifications

Parameter
Number of poles 1P+N
Communication mode Wi-Fi
Degree of protection (IP) IP20
Application for mobile devices Smart Life/Tuya Smart
Rated. current In 32A/ 40A/63A/ 80A
Types of RCD AC type
Tripping characteristic C
Frequency 50 Hz
Rated. voltage 1P+N:230/240V
Complies with standard IEC 61009-1、IEC 60898-1
Rated short circuit breaking capacity Icn 6 kA
Mechanical service life 10000 Times
Electrical service life 6000 Times
Dimension 1P+N (L*H*W:90*72*53 mm)

Tripping characteristics (Reference temp.30)

Item Test current In(A) Initial Status Time limit for tripping or non-tripping Expected result Remarks
a 1.13In Cold t ≤ 1h(In ≤ 63A)
t ≤ 2h(In > 63A)
Non-tripping
b 1.45In Following item a test t < 1h(In ≤ 63A)
t < 2h(In > 63A)
Tripping Current smoothly rises to specified value within 5s
c 2.55In Cold 1s < t < 120s Tripping
d 5In Cold t ≤ 0.1s Non-tripping Switch on the power supply by closing the auxiliary switch
e 10In Cold t < 0.1s Tripping Switch on the power supply by closing the auxiliary switch

Note: The term “cold” means that the test is carried out at a refeerence calibration temperature without load before the test.

Why Choose CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.


30+

YEARS EXPERIENCE

Specialized in low-voltage electrical manufacturing


1100+

EMPLOYEES

Professional team ensures stable quality and delivery


100M+

POLES ANNUAL CAPACITY

Large-scale production capacity to meet global demand


90%

AUTOMATED PRODUCTION

Advanced automation for high efficiency and consistency

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

IEC Certification
CE Certification
CB Certification
RoHS Certification
ISO 14001 Certification

Strict quality control system ensures every product meets global standards.

What Can We Customize?

For CQB7ZNM-80 projects, CHAC can review private-label marking, packaging, approved appearance options and the published electrical configurations. Requests outside the published range require engineering evaluation, testing and feasibility review.

Logo & Branding

Custom logo printing, laser marking and nameplate solutions.

Logo & Branding

Packaging
Customization

Customized color boxes, cartons, labels and manuals.

Packaging Customization

Electrical
Customization

Current, voltage, breaking capacity, trip curve and other
special functions.

Electrical Customization

Product
Appearance

Housing color, handle color and appearance customization.

Product Appearance

Certification
Support

Products comply with international standards and market
requirements.

Certification Support

Engineering
Development

Drawing evaluation, prototype testing and mass production.

Engineering Development

Download

PDF

Smart Circuit-Breaker

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Contact Us

CQB7ZNM-80 Product FAQ

What is the CQB7ZNM-80 used for?

The CQB7ZNM-80 is specified for overload, short-circuit, leakage and voltage monitoring functions in 230/240V AC applications, within the ratings and configurations listed in its technical table. Final suitability depends on the complete circuit design.

What can the CQB7ZNM-80 smart function control?

The published page describes WiFi monitoring and remote control through Smart Life/Tuya. Confirm network availability, permissions, local override, outage behaviour and the independent operation of the protective function.

How do I choose the CQB7ZNM-80 rating and poles?

Start with the design current and system arrangement, then choose only a published option. The page lists pole options as 1P+N; confirm neutral, polarity, conductors and isolation requirements.

What safety limitation applies to the CQB7ZNM-80?

Do not treat the CQB7ZNM-80 as a universal substitute for another device. Confirm C curve; AC residual-current type listed, the system voltage, fault or leakage conditions and any separate upstream protection before selection.

Can the CQB7ZNM-80 be used in another circuit type?

Only when the exact ordered configuration is rated for that circuit. AC and DC duties, residual-current devices, isolators, smart controls and voltage protectors are not interchangeable by appearance or current rating.

How should the CQB7ZNM-80 be installed and tested?

Use the exact product drawing, terminal identification and instructions. A qualified person should verify isolation, conductors, torque, settings, coordination and functional tests before energising the circuit.

Confirm the Right CQB7ZNM-80 Configuration

Send the model, rating, poles, system voltage, application, quantity and document requirements. CHAC will review the request against the published data.

Request a Quote