MCB, RCCB & RCBO Supply for Electrical Brands

OEM/ODM Customization Solutions for Terminal Electrical Products

CHAC manufactures MCBs, RCCBs and RCBOs for electrical brands, importers and distributors. Start with the models and quantities your market needs, then discuss product markings, packaging and supporting documents. For a new design, send your application requirements or drawings for an ODM feasibility review.

Branding and Configuration for Your Circuit Breaker Range

Discuss the options below for your chosen circuit breaker series. Available configurations and any development work are agreed model by model.

LOGO

Product Markings

Plan the logo position and product identification while keeping required ratings, model details and symbols readable.

Logo & Branding

Packaging and Instructions

Specify box artwork, carton labels and instruction language for the models in your range.

Packaging Customization

Protection Ratings

Choose the current, poles and protection characteristics for the device you need. Available combinations depend on the selected series.

Electrical Specifications Customization

Housing and Handle Options

Discuss available appearance options for the chosen series. Changes affecting fit or operation require engineering review.

Product Appearance

Documents for Your Market

Name the destination market and required reports or certificates. CHAC can review the available documents for the exact model; any effect of private-label markings on document coverage also needs confirmation.

Certification Support

Design Changes

Identify the housing, mechanism or function you need to change. Development scope, tooling and testing are assessed through the ODM route below.

Engineering Development
OEM & ODM services

Circuit Breaker OEM Branding and ODM Development

Choose the route that fits your order: brand an existing series, or request an engineering review when the product design needs to change.

Circuit breaker components on CHAC Electric's automated assembly line
OEM / PRIVATE LABEL

Brand an Existing Circuit Breaker Series

An existing model is the starting point when you need your own product identity without a new breaker design. Select the configuration, then approve a sample and artwork as the reference for production.

Send your model list, destination market, quantities and brand artwork.
CHAC Electric team reviewing improvement proposals and technical information
ODM / DEVELOPMENT REVIEW

Review Changes to the Breaker Design

Choose a development review when an existing series does not meet your design requirements. CHAC assesses the proposed changes before you agree on tooling, testing, costs and sample approval. Feasibility is established before development begins.

Send the application, drawings or sample reference, and the changes you need.

How Your Circuit Breaker Order Moves Into Production

Set the order scope first, approve the product and artwork, then agree on production checks and delivery. The quotation should state which approvals or payments start the agreed lead time.

01
Define the Order

List the models, market, protection ratings and quantities.

02
Agree on Scope

Confirm branding, development work and responsibilities.

03
Review the Design

Check configurations, drawings and any tooling changes.

04
Approve the Sample

Approve the product, markings, documents and packaging.

05
Confirm Production Requirements

Record approved versions, batch checks and the agreed delivery milestone.

06
Produce and Deliver

Confirm the order mix, packing list and shipping terms.

PRODUCT
04

Build Your Terminal Electrical Product Range

Choose the protection devices your customers need, then add accessories or isolation products where required. Check the ratings and dimensions for each series; sharing a DIN rail does not establish compatibility.

Build Your Breaker Brand with CHAC

Share your models, quantities and branding ideas with CHAC Electric to discuss the product configuration, customization scope and quotation for your range.

Get Your OEM & ODM Plan
Procurement requirements

Circuit Breaker Specifications for Your Enquiry

MCBs, RCCBs and RCBOs perform different protection tasks. Use the checklist for the device you need, and include the application, destination standard and quantity with your enquiry.

MCB Ratings and Tripping Curve

Overload and short-circuit protection

Specify voltage, rated current, poles, tripping curve and breaking capacity. Match the curve to the load characteristics and check the breaking capacity against the fault level at the installation point.

View MCB specifications →

RCCB Type and Sensitivity

Residual-current protection

Specify rated current, poles, residual-current type and rated residual operating current. Include the separate overcurrent protective device so the proposed combination can be reviewed. An RCCB does not provide overload or short-circuit protection by itself.

View RCCB specifications →

RCBO Protection and Panel Fit

Combined residual-current and overcurrent protection

Give RCBO suppliers the rated current, tripping curve, breaking capacity, residual-current type and sensitivity you need. Check the pole arrangement, neutral connection, terminals and module width against your panel drawing.

View RCBO specifications →
Ordering & repeat supply

From Your First Order to Repeat Supply

Turn your product list into a clear order: define quantities, separate product and service costs, and keep approved versions for delivery and repeat supply.

CHAC Electric assembly facilities

Plan Quantities for Your First Breaker Order

As your MCB supplier, CHAC can review a model-by-model quantity list with your branding and packaging needs. Include the current rating and pole arrangement for each item, and separate the first order from expected repeat demand. The applicable minimum quantities, mixed-order options and delivery dates need confirmation for the proposed product mix before you place the order.

Send a model-by-model quantity list, destination market, packaging needs and required delivery milestone.

Testing facilities shown by CHAC Electric

What Your RCBO Quotation Includes

CHAC prepares your RCBO quotation around the agreed configuration, quantities and branding requirements. CHAC’s OEM/ODM customization quotation includes the costs of product compliance testing and reliability verification within the agreed project scope. Any sample, packaging, tooling or additional document charges are itemized separately. When comparing RCBO manufacturers, use the same product specifications and testing scope. Confirm the EXW or FOB terms, named place or port, payment terms and delivery schedule before placing your order.

Your quotation records the product and testing scope, included costs, additional charges and delivery terms.

CHAC Electric staff member operating inspection equipment

Keep Deliveries and Repeat Orders Traceable

As an RCCB manufacturer, CHAC uses the full model reference and agreed configuration to review your repeat-order requirements. Send the previous order number, approved drawings and artwork revision, with any changes clearly marked. Include the residual-current type, sensitivity, rated current and poles. For shortages, damage or suspected defects, provide the order reference, product or carton identification, quantities and photos so the issue can be reviewed before any return shipment is agreed.

Retain the approved versions, packing list and order references for receiving checks, feedback and repeat orders.

Manufacturing Support for Your Electrical Brand

Your Brand. Our Manufacturing. Since 1995.

CHAC has manufactured low-voltage electrical products since 1995. As an MCB manufacturer, CHAC supports your order review with model-specific specifications and dimensions. The approved sample, inspection requirements and packaging revision provide the production reference. Capacity and delivery are confirmed for the series and quantities in your order.

30+

Years of Manufacturing

Low-voltage electrical manufacturing since 1995.

1100+

Employees Across CHAC

Company-wide team supporting manufacturing and engineering.

100M+

Breaker Poles per Year

Company-wide breaker pole capacity; confirm output for your chosen series.

90%

Production Automation

Company-wide automation figure; process coverage varies by product line.

Figures shown are company-wide. Ask us about capacity and automation for the product line you need.

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

Terminal Electrical Line

Terminal Electrical Line

 Distribution Box Line

Distribution Box Line

MCCB Line

MCCB Line

Industrial Control Line

Industrial Control Line

Procurement FAQ

Circuit Breaker Procurement Questions

Resolve the key selection questions, then discuss minimum quantities, samples, delivery dates and packing for your order.

CHAC Electric company building
Should I choose a 6 kA or 10 kA MCB?

Select breaking capacity against the prospective short-circuit current at the installation point. Send CHAC the system voltage, required fault rating and applicable standard to check the available models. Have the project designer confirm the requirement; the current rating alone is not enough, and 6 kA and 10 kA are not equivalent.

Can I keep my busbar when changing MCB brands?

Only after checking it against the replacement model. Review tooth type, spacing, terminal position and connection method, then check the proposed assembly before approval. Send CHAC the busbar and panel drawings; mounting on the same DIN rail does not establish busbar compatibility.

What should I check before placing a bulk MCB order?

Check the sample’s ratings, poles, curve, dimensions, terminals and markings against the agreed specification. Confirm that required reports cover the exact model and configuration. Keep the approved sample reference, drawing revision and packaging artwork with the purchase order.

How are minimum quantities and mixed breaker orders agreed?

Send CHAC the quantity for each model, current rating and pole configuration, together with any branded packaging requirements. Request the minimum quantity for each configuration and packaging version, and ask whether the proposed mix can be combined in one order. Keep the agreed quantities in the quotation; a total for the whole range does not identify the quantity of each item.

How do we arrange samples and agree on the production lead time?

Identify the model, ratings, markings and packaging you want the sample to represent, then request sample availability, charges and dispatch timing from CHAC. For the production order, agree on which approvals or payments start the schedule and whether the quoted date means production completion or carrier handover. Record the milestone in writing and treat estimated transit time separately.

Can the quote include carton sizes, weights and pallet details?

Ask CHAC for units per carton, carton dimensions, net and gross weights, and any pallet arrangement for the proposed order. Packaging and model mix can affect these figures. Use the final packing list to confirm freight and storage requirements before dispatch.

Procurement resources

MCB & RCD Buying Guides

Compare suppliers, protection functions and pole arrangements before you finalize your product list.

Supplier comparison

Choosing an MCB Manufacturer

Compare ten suppliers and the model documents, samples and supply terms to request before approving a quotation.

Protection selection

MCB vs RCBO: What Should You Order?

Understand the protection differences and how the choice affects circuit layout, residual-current requirements and cost.

Order configuration

Single-Pole vs Double-Pole MCBs

Check the supply, isolation and neutral-switching requirements before specifying the pole arrangement in your order.

Tell Us About Your OEM & ODM Project

Tell CHAC which breakers you need, where you sell them and how you want them branded. Include quantities and any design changes so the discussion can cover suitable models, OEM or ODM scope, sample requirements and quotation terms. If you have not selected a model, describe the application instead.

CHAC Product Combination

What to Include in Your Enquiry

Model or application · Required ratings · Quantity per configuration · Destination market · Branding or design changes · Delivery needs

See the specification checklist →

Discuss Your Circuit Breaker Project

Contact Form Demo