CHAC Electric · MCB Manufacturer

Miniature Circuit
Breakers (MCB)

CHAC supplies miniature circuit breakers for panel builders, distributors and electrical brands. Compare series by current, poles, trip curve and breaking capacity, then discuss bulk supply or OEM requirements.

  • Overcurrent protectionOverload and short circuit
  • Pole optionsConfirm by series
  • Breaking capacityMatch the fault level
  • OEM & ODMBranding and packaging
MCB fundamentals

What Is a Mini Circuit Breaker?

A mini circuit breaker, or miniature circuit breaker (MCB), protects a circuit against overload and short-circuit current within its stated ratings.

It does not, by itself, provide residual-current protection. Where earth-leakage protection is required, review the appropriate RCCB and MCB arrangement or an RCBO.

01

Normal load

Current remains within the selected operating characteristics.

02

Overload or short circuit

The device responds according to its time-current characteristic.

03

Circuit interruption

Operation depends on the fault conditions and the device’s applicable ratings.

CHAC mini circuit breakers provide overload and short-circuit protection for residential, commercial and OEM distribution applications. Our miniature circuit breaker range can be selected by rated current, pole configuration, tripping curve and breaking capacity to match different final-circuit requirements.

Compare CHAC MCB series

Compare PXB6-40, CQB2-63 and CQB2H-63

Compare three CHAC series by current, poles, trip curve and short-circuit rating.

Selection factor
Selection focus1P+N circuits6kA Icn requirements10kA Icn requirements
Rated current6–40A6–63A6–63A
Number of poles1P+N1P / 1P+N / 2P / 3P / 3P+N / 4P1P / 2P / 3P / 4P
Trip curvesB / C / DB / C / DB / C / D
Short-circuit rating4.5kA · Icn = Ics6kA · Icn = Ics10kA · Icn
Product standardIEC 60898-1IEC 60898-1IEC 60898-1
Series cataloguePXB6 Series Catalogue ↗CQB2 Series Catalogue ↗CQB2 Series Catalogue ↗

Confirm the operating voltage, pole arrangement and available fault current before selecting a series.

Not Sure Which MCB to Choose?

Share your circuit requirements with CHAC for help choosing an MCB series.

MCB types and selection

How to Specify the Right MCB

Match your circuit requirements to the MCB rating, trip curve and panel layout.

  1. Current Rating

    Match the MCB rating to the design load and cable capacity, allowing for temperature and grouping.

  2. B, C or D Curve

    Check load inrush and the fault current needed to meet the required disconnection time.

  3. Breaking Capacity

    Check the short-circuit rating at your system voltage against the available fault current.

  4. Pole Arrangement

    Choose the protected and switched conductors for your supply system and neutral requirements.

  5. DIN Rail & Panel Fit

    Check dimensions, terminal access and busbar connections for the selected model.

  6. Technical Documents

    Confirm the model, destination market and required drawings, certificates or test reports.

Common MCB Current Ratings

Compare PXB6-63 and CQB2-63 for these current options. Select the current rating for the load and conductor capacity, allowing for temperature and grouping.

6A, 10A and 16A options. Both series list these ratings. Include the pole arrangement and B, C or D trip curve when requesting a quote.

20A, 25A and 32A options. These ratings are also available in both series. For a 32A MCB, check load inrush and the required trip curve as well as the current rating.

40A, 50A and 63A options. Both series extend to 63A. For a 63A MCB order, confirm terminal access, panel space and the applicable breaking rating at the system voltage.

MCB circuit requirements

MCB Options for Your Circuit

Use the load, switching arrangement and fault level to narrow your choice before checking the technical data.

PXB6-40

Phase and neutral switching

For a 1P+N requirement, review PXB6-40 and confirm which conductors need protection and disconnection.

Review PXB6-40 specifications →
Technical resources

MCB Technical Reference Center

Find trip curves, installation dimensions and catalogues for your CHAC MCB series.

Curve
PXB6-40 published tripping curves
PXB6-40 · Tripping curvesOpen original ↗
Inside CHAC Electric

Inside the CHAC MCB Factory

CHAC has manufactured low-voltage electrical products since 1995. Our facilities include assembly equipment, a testing laboratory and quality inspection equipment.

  • Automated assemblyAutomated assembly equipment within CHAC’s manufacturing facilities.
  • Testing laboratoryLaboratory facilities for electrical product testing.
  • Quality inspectionInspection equipment used by CHAC factory staff.
Cooperation for electrical brands

MCB OEM & ODM Solutions for Your Brand

CHAC is a miniature circuit breaker supplier for distributors, panel builders and electrical brands. Choose an existing series for private-label supply, or discuss a new design through a separate ODM review.

CHAC terminal electrical manufacturing facilities

Choose How to Build Your Product Line

  • OEM: build on an existing seriesApply your brand to an agreed CHAC MCB series through product marking and packaging.
  • ODM: review a proposed design changeDiscuss a new design or changed specification with CHAC before development is agreed.
  • Approve before productionReview the sample and artwork, then retain the approved references for repeat orders.
Explore MCB OEM & ODM

Customization scope, minimum order quantity and lead time depend on the agreed project.

Prepare your bulk MCB enquiry

What to Send for an MCB Quotation

Help MCB suppliers quote the same product and supply scope. Include the electrical specification, quantities, branding brief and delivery terms.

CHAC circuit breaker packaging customization examplesProduct packaging and brand presentation
  1. 01

    Model and electrical requirements

    List the model, current, poles, curve, voltage and required short-circuit rating, including Icn, Icu or Ics where specified.

  2. 02

    Quantities and destination market

    Give quantities by configuration, the destination market and any required standards, documents or inspections.

  3. 03

    Branding and packaging brief

    Specify CHAC branding or private label. For OEM orders, include artwork, label language and box or carton requirements.

  4. 04

    Delivery terms and timing

    State the trade term and named port or place, plus your required delivery date. CHAC will confirm timing for the order.

MCB knowledge and purchasing guides

MCB Selection and Purchasing Guides

Read more about protection functions, pole arrangements and panel fit before confirming your specification.

Selection guide

MCB vs RCBO: Which Protection Does the Circuit Need?

Understand when overcurrent protection alone is insufficient and how the protection functions differ.

Read the guide →
Selection guide

Single-Pole and Double-Pole MCB Selection

Review pole arrangements before specifying switching and isolation requirements.

Read the guide →
Selection guide

DIN Rail Circuit Breaker Dimensions and Panel Fit

Check physical dimensions, enclosure space and compatibility instead of relying on the rail format alone.

Read the guide →
MCB buying questions

What Buyers Ask Before Ordering

Answers to common questions about MCB ratings, protection functions and bulk supply.

Do I need a 6kA or a 10kA MCB?

Use the prospective short-circuit current at the installation point and the project protection study to establish the requirement. CQB2-63 has a 6kA rating, while CQB2H-63 has a 10kA Icn rating. Check the voltage, standard and exact configuration before comparing them; rated load current in amperes is a separate value.

How do I choose a B, C or D curve MCB?

Match the curve to load inrush and the fault current available for timely operation. A B curve MCB and a C curve MCB have different instantaneous trip characteristics, so equal current ratings do not make them interchangeable. Several CHAC series list B, C and D options; CQB2-125 lists C and D. Use the selected series’ curve data and the installation requirements.

Is a 1P+N MCB the same as a 2-pole MCB?

Not necessarily. They may differ in which poles provide overcurrent protection and which conductors are switched. PXB6-40 is a 1P+N series; other series offer different pole arrangements. Confirm the supply system, neutral requirement and product diagram before specifying the order.

Can an AC MCB also provide earth-leakage or DC protection?

Do not assume either function. An MCB provides overload and short-circuit protection within its stated ratings. Evaluate an RCCB or RCBO arrangement when residual-current protection is required, and use a specifically rated DC device for a DC circuit. Check the individual product data.

Can CHAC supply MCBs with our logo and packaging?

Yes. CHAC supports OEM product marking and packaging for electrical brands, importers and distributors. New designs or changed electrical specifications require a separate ODM review.

How can I compare miniature circuit breaker prices?

Ask each MCB supplier to quote the same electrical specification, quantity and delivery terms. Check whether branding, packaging, samples and technical documents are included.

Ready to Discuss Your MCB Order?

Share your model, quantities and destination market with CHAC to discuss supply and OEM requirements.

CHAC Electric

Tell Us What You Need

MCB selection, bulk orders or OEM & ODM cooperation.

CHAC Electric

Your MCB Requirements

Share the details you know. Leave undecided items unconfirmed.