Fabricante OEM de Contactores AC Industriais Série CQC6

O Fabricante OEM de Contactores AC Industriais Série CQC6 is a CHAC AC contactor for remote switching and motor control. The page keeps the model-specific technical table and original product images so buyers can verify voltage, current, configuration, mounting and applicable standards before ordering. Final suitability depends on the complete circuit, installation method and destination-market rules.

Product family:
Contactor AC
Primary function:
remote switching and motor control
Typical context:
motor starters, HVAC and automation panels
Technical data:
See verified model table below
Configuration:
Confirm the exact model variant
Support:
OEM/ODM review available

Visão Geral do Produto

CQC6 Series Industrial AC Contactor OEM Manufacturer is a AC contactor intended for remote switching and motor control. The current product record identifies it for motor starters, HVAC and automation panels. Use the exact model variant and preserved technical source as the basis for procurement rather than assuming that every family member has the same rating.

Verified source summary: Type designation Dimensions (mm) Model number Amax Bmax Cmax Dmax a/a' b C Ф CQC6-06~25 46 76 83 117 35 50 60 Ф4.5 CQC6-32~38 57 85 96 130 40/43 48 / Ф4.5 CQC6-40~65 76 128 115 149 40/59 100 110 Ф5.5 CQC6-80~95 85 128 124 158 40/67 100 110 Ф5.5 Accessories Description Contact Configuration Technical Specifications Model number CQC6 -6 CQC6 -9 CQC6 -12 CQC6 -18 CQC6 -25 CQC6 -32 CQC6 -38 CQC6 -40 CQC6 -50 CQC6 -65 CQC

Principais Características

  • Product type: AC contactor.
  • Primary function: remote switching and motor control.
  • Application context: motor starters, HVAC and automation panels.
  • Model variants, dimensions and ratings remain in the preserved technical source.
  • Confirm installation method, environmental limits and local compliance before release.

Aplicações Típicas

Typical use can include motor starters, HVAC and automation panels when the project confirms system voltage, current, fault or surge exposure, conductor and enclosure requirements, and the selected variant’s installation instructions. This page does not replace the project design or the authority having jurisdiction.

Guia de Candidaturas e Seleção

Use the following decision points with the preserved model data. Product-family descriptions explain intent, but the exact technical table controls the ordered variant.

Ponto de seleção Fabricante OEM de Contactores AC Industriais Série CQC6 O que o projeto deve confirmar
Aplicação AC Contactor projects Confirm the actual system and environment
Selection basis remote switching and motor control Use the exact model and technical table
Instalação Follow the model instructions Check mounting, clearances and termination
Compliance Use the listed standard where applicable Verify edition, scope and destination rules
Adjacent product Evaluate the related CHAC family where function differs Do not substitute without engineering review

Function

remote switching and motor control

Match the protection or switching function to the system.

View related guidance →

Configuração

Model-specific options

Confirm current, voltage, poles, terminals or accessories from the table.

View related guidance →

Instalação

Mechanical and electrical fit

Check enclosure, mounting, wiring space and maintenance access.

View related guidance →

Project evidence

Documents and test records

Retain the approved drawing, technical sheet and commissioning record.

View related guidance →

Guia de Encomenda

  1. State the exact model and variant.
  2. Provide the system voltage, current, frequency and load or protection function.
  3. Confirm mounting, terminals, accessories, enclosure and environmental conditions.
  4. Share quantity, destination market and required technical documents.

Verificações de Instalação e Coordenação

  • Verify the model’s ratings and connection arrangement against the project drawings.
  • Check conductor, busbar, enclosure, clearances and tightening requirements using the product documentation.
  • Coordinate upstream and downstream protection or control devices where applicable.
  • Use qualified personnel for installation, testing, isolation and maintenance.

Designação do tipo

Dimensões (mm)

Número do modelo Amax Bmax Cmax Dmax a/a’ b C Ф
CQC6-06~25 46 76 83 117 35 50 60 Ф4.5
CQC6-32~38 57 85 96 130 40/43 48 / Ф4.5
CQC6-40~65 76 128 115 149 40/59 100 110 Ф5.5
CQC6-80~95 85 128 124 158 40/67 100 110 Ф5.5

Descrição dos Acessórios

Contact Configuration

Especificações Técnicas

Número do modelo CQC6
-6
CQC6
-9
CQC6
-12
CQC6
-18
CQC6
-25
CQC6
-32
CQC6
-38
CQC6
-40
CQC6
-50
CQC6
-65
CQC6
-80
CQC6
-95
Rated insulation voltage (Ui) 690V
Tensão estipulada de resistência a impulsos (Uimp) 8kV
Frequência nominal 50Hz, 50/60Hz
Number of poles (P) 3
Rated Operational Current (A)- AC-3 220V/230V 6 9 12 18 25 32 38 40 50 65 80 95
380V/400V 6 9 12 18 25 32 38 40 50 65 80 95
660V/690V 4.8 6.6 8.9 12 18 20.2 20.2 34 39 42 49 49
Conventional Free-Air Thermal Current (A) (AC-1, θ ≤ 60℃) 20 25 25 32 40 50 50 60 80 80 110 110
Short-Time Withstand Current (A) 10s 80 105 105 145 145 260 310 320 400 520 640 800
1min 45 61 61 84 84 138 150 165 208 260 320 400
10min 20 30 30 40 40 60 60 72 84 110 135 135
Controlled 3-Phase Squirrel Cage Motor Power (kW) – AC-3 220V/230V 1.5 2 3.5 4 6 7.5 9 11 15 18.5 22 25
380V/400V 2.2 4 5.5 7.5 11 15 18.5 18.5 22 30 37 45
660V/690V 3 5.5 7.5 10 15 18.5 18.5 30 33 37 45 45
Short-circuit protection by gG fuses (U ≤ 690V) for Type 2 coordination, without integral thermal overload relay 20 25 25 32 40 50 50 60 80 80 110 110
Electrical Endurance (104 operations) 120 100 80
Rated Making Capacity (AC-3) 10 × Ie, in accordance with IEC 60947-4-1 and GB/T 14048.4.
Rated Breaking Capacity (AC-3) 8 × Ie, in accordance with IEC 60947-4-1 and GB/T 14048.4.
Characteristics of AC controlcircuits
Operating Frequency (operations/h) 1200 600
Mechanical Life (104 operations, 3600 ops/h) 1200 1000 800 600
AC Coil Power (50/60Hz) Pick-up (VA) 70 110 200 200
Sealed (VA) 8 11 20 20
Operate Time (ms) Close 12-22 12-22 20-35 20-35
Open 4-19 4-19 6-15 6-15
Operate Voltage Range (50/60Hz) Pick-up Voltage: 80%Us ~ 110%Us; Drop-out Voltage: 20%Us ~ 75%Us
Rated Control Supply Voltage Us AC 24/36/48/110/220/230/380/400/415/440V, 50/60Hz
Applicable accessories Auxiliary contact block
Coil surge absorber
Main circuit conductor
Mechanical interlock
Mechano-electrical interlock
DIN rail mounting
Certifications obtained CCC CE CB

Main Circuit Conductor (Busbar)

Produto
Modelo
Upper Conductor Lower Conductor Conductor Applicable Models
Amax Bmax Cmax Amax Bmax Cmax Dmax
F1-H1 88 24 28 88 17 28 2.5mm2 CQC6-06/18
F1-H2 103 29 33 103 20 35 6mm2 CQC6-25/38
F1-H3 134 43 55 134 30 50 10mm2 CQC6-40/65
F1-H4 150 52 51 150 37 50 16 mm2 CQC5-80/95

Electrical/Mechanical Interlock

Product Name Content Modelo de produto Applicable Models Wiring Diagram (ME)
Electrical Interlock Electrical Interlock Kit F2-LS3 CQC6-06~38
Electrical Interlock Kit F2-LS4 CQC6-40-95
Mechanical Interlock Mechanical Interlock Kit F2-LS1 CQC6-06~38
Mechanical Interlock Kit F2-LS2 CQC6-40~95

Component size diagram (mm)

RC Snubber (Coil Surge Suppression)

Modelo de produto Content Applicable Models Dimensões (mm)
F3-LY2EA AC 24…48V CQC6-06~38
F3-LY2GA AC 50…127V
F3-LY2UA AC 110…240V
F3-LY2NA AC 380…415V CQC6-40~95
F3-LY2FC AC 24…48V
F3-LY2GC AC 50…127V
F3-LY2UC AC 110…240V
F3-LY2NC AC 380…415V

Contactos Auxiliares

Product Name Modelo de produto Content Applicable Models Dimensões (mm)
Top-Mounted Auxiliary
(2 Contacts)
F4-11 1NO + 1NC CQC6-06~95
F4-20 2NO
F4-02 2NC
Top-Mounted Auxiliary
(4 Contacts)
F4-22 2NO + 2NC
F4-40 4NO
F4-04 4NC
F4-13 1NO + 3NC
F4-31 3NO + 1NC
Parâmetros Elétricos
Conventional Thermal Current Ith 10A
Rated Insulation Voltage Ui 690V
Rated Impulse Withstand Voltage Uimp 6kV
Minimum Switchable Load 6V 100mA
Utilization Category Rated Operational Voltage (V) Rated Operational Current (A)
AC-15 380 0.95
220 1.6
DC-13 220 0.15

On-Delay Timer (Timer Head)

Modelo de produto Content Applicable Models
F5-T0 0.1…3s CQC6-06-95
F5-T2 0.1…30s
F5-T4 10…180s
F5-S2 1…30s
F5-D0 0.1…3s
F5-D2 0.1…30s
F5-D4 10…180s

Side-Mounted Auxiliary

Modelo de produto Content Applicable Models
F8-11 1NO + 1NC CQC6-06-95
F8-20 2NO
F8-02 2NC

Porquê escolher a CHAC

Com mais de 30 anos de experiência em fabrico, mais de 1100 funcionários, mais de 100 milhões de postes
Com uma capacidade anual e um processo de produção automatizado 90%, a CHAC garante uma capacidade de produção estável e rigorosos
Controlo de qualidade para clientes OEM/ODM globais. O nosso sistema de fabrico interno suporta a longo prazo
cooperação para marcas elétricas, importadores e distribuidores.


30+

ANOS DE EXPERIÊNCIA

Especializado em fabrico de baixa tensão elétrica


1100+

FUNCIONÁRIOS

Equipa profissional garante qualidade e entrega estáveis


100M+

CAPACIDADE ANUAL DE POSTOS

Capacidade de produção em larga escala para satisfazer a procura global


90%

PRODUÇÃO AUTOMATIZADA

Automação avançada para alta eficiência e consistência

Linha de Montagem Automatizada

Linha de Montagem Automatizada

Laboratório de Ensaios

Laboratório de Ensaios

Injeção e Estampagem

Injeção e Estampagem

Inspeção de Qualidade

Inspeção de Qualidade

Certificação IEC
Certificação CE
Certificação CB
Certificação RoHS
Certificação ISO 14001

Um rigoroso sistema de controlo de qualidade garante que cada produto cumpre as normas globais.

O que podemos personalizar?

A CHAC suporta a personalização da tensão da bobina e da configuração dos contactos auxiliares,
parâmetros elétricos, branding do produto, design de embalagem e desenvolvimento de engenharia de acordo com os equipamentos dos clientes e os requisitos do mercado.

Tensão da bobina

Tensão da bobina

Opções de tensão de bobina AC e DC adaptadas aos requisitos da aplicação.

Personalização da tensão da bobina para opções de tensão de bobina AC e DC
Contactos Auxiliares

Contactos Auxiliares

Combinações flexíveis de contactos auxiliares para diferentes funções de controlo.

Personalização de contactos auxiliares para diferentes funções de controlo
Parâmetros Elétricos

Parâmetros Elétricos

As classificações atuais, os intervalos de proteção e os parâmetros funcionais podem ser personalizados.

Personalização de parâmetros elétricos para classificações de corrente e intervalos de proteção
Branding de Produto

Branding de Produto

Logótipos de marca própria, placas de identificação e suporte para identificação de produtos.

Personalização da marca do produto, incluindo logótipos de marca própria e placas de identificação
Design de Embalagem

Design de Embalagem

Caixas personalizadas, etiquetas, manuais e soluções de embalagem.

Personalização de design de embalagens, incluindo caixas, rótulos, manuais e soluções de embalagem
Desenvolvimento de engenharia

Desenvolvimento de engenharia

Suporte desde a otimização de desenhos ao desenvolvimento de produtos e à compatibilidade de aplicações.

Apoio ao desenvolvimento de engenharia, desde a otimização de desenhos até ao desenvolvimento de produtos

Transferir

PDF

Contator AC Série CQC6

Visão geral completa de componentes elétricos de baixa tensão e referência para seleção de produtos.

Transferir PDF

SUP

Precisa de Documentos Técnicos?

Contacte-nos para folhas de dados, certificados, desenhos, orientação de seleção ou suporte a projetos OEM/ODM.

Contacte-nos

CQC6 Product FAQ

What loads can the CQC6 contactor switch?

Use the published utilization category, operational current and voltage for the selected variant. Resistive, motor and capacitive loads require different checks.

How do I select an AC contactor size?

Start with load current, utilization category, starts per hour, coil voltage, poles and short-circuit coordination. Current alone is not enough.

Can a thermal relay be paired with it?

Where the product record supports the combination, a thermal relay can form a motor starter. Confirm mechanical fit, current range and control wiring.

Which coil voltage should I specify?

Match the control supply shown on the project drawing with the coil option for the exact model. Never assume the coil voltage from the main circuit.

What accessories are available?

Auxiliary contacts, timers, interlocks or other accessories depend on the series and variant. Confirm the compatible accessory list before ordering.

How should a contactor be commissioned?

Verify terminal torque, coil voltage, contact sequence, insulation and operating current, then record the test results.

Confirm the Right CQC6 Configuration

Send the exact model, operating conditions, quantity, destination market and required documents. CHAC will review the request against the published product data.

Pedir um orçamento