Disjuntor de Corrente Residual da Série CQM5L

O CQM5L MCCB provides overload, short circuit and residual-current protection within its published 10–630A range. Specification should follow the system voltage, load, conductor coordination, prospective fault current and applicable rules—not the ampere value alone.

Polacos:
3P / 4P
Corrente Nominal:
10–630A
Tensão Nominal:
AC 380/400/415V
Trip / Protection:
overload, short circuit and residual-current protection
Dados de Última Hora:
70kA Icu; 50kA or 70kA Ics by configuration
Normal
IEC 60947-2 and GB/T 14048.2

Visão Geral do Produto

CQM5L is a residual current circuit breaker for AC 380/400/415V distribution and protection applications. Its published range covers 10–630A with 3P / 4P options. Selection depends on the complete power-system design, including fault level, coordination, conductor ampacity, enclosure conditions and local rules.

The saved model record lists IEC 60947-2 and GB/T 14048.2 as the applicable standard reference. No certification claim is added beyond the model record.

Principais Características

  • Published current range: 10–630A.
  • Pole options: 3P / 4P.
  • Protection function: overload, short circuit and residual-current protection.
  • Trip or setting information: thermal-magnetic trip.
  • Short-circuit data: 70kA Icu; 50kA or 70kA Ics by configuration.
  • Electrical reference: AC 380/400/415V.
  • Accessories, terminals and installation details must be confirmed for the ordered frame and configuration.

Aplicações Típicas

Typical applications include distribution and motor circuits where the project requires integrated residual-current protection. These are evaluation contexts rather than universal approvals. Confirm the exact frame, voltage, breaking duty, trip unit, accessories and installation method before specification.

Guia de Candidaturas e Seleção

Use the verified CQM5L values below to create a shortlist, then validate the complete circuit. An MCCB rating does not replace conductor calculations, fault-current analysis, coordination review or local installation requirements.

Ponto de seleção CQM5L reference O que o projeto deve confirmar
Corrente nominal 10–630A Design current, conductor ampacity, installation method, temperature and grouping
Tensão AC 380/400/415V Sistema de alimentação e classificação de equipamento
Polacos 3P / 4P Live conductors and neutral treatment
Trip / protection thermal-magnetic trip Load profile, fault response and coordination
Capacidade de corte 70kA Icu; 50kA or 70kA Ics by configuration Prospective short-circuit current at the installation point

Overcurrent vs Earth-Leakage Protection

An MCCB's overcurrent function does not replace residual-current protection. Select leakage sensitivity, delay and waveform type from the verified model data and project rules.

Leakage Protection
Confirm Leakage Selection →

MCCB vs MCB

An MCCB is normally evaluated for higher current, fault duty or accessory flexibility; an MCB may be more suitable for compact final circuits.

Current & Fault Duty
Compare MCCB and MCB →

Icu vs Ics

The saved data for CQM5L lists 70kA Icu; 50kA or 70kA Ics by configuration. Match the declared duty to the prospective short-circuit current and continuity objective.

Short-Circuit Study
Review Technical Support →

Pole and Neutral Arrangement

Published pole options are 3P / 4P. Confirm which conductors must be switched, protected and isolated together.

System Arrangement
View MCCB Range →

Guia de Encomenda

  1. State the exact model: CQM5L.
  2. Provide frame and rated current within the published range: 10–630A.
  3. Confirm poles: 3P / 4P.
  4. Specify the trip unit or protection function: thermal-magnetic trip.
  5. Provide system voltage, frequency, application, expected fault level, destination market and quantity.
  6. List required accessories, terminals, documents and any approved OEM/ODM marking or packaging requirements.

Verificações de Instalação e Coordenação

  • Use the exact model drawing and instructions; do not infer terminal positions, supply direction or accessory compatibility from another MCCB.
  • Verify conductor material and cross-section against the circuit calculation, terminal data, temperature and grouping.
  • Confirm Icu/Ics or DC fault duty, upstream/downstream coordination, enclosure conditions, altitude and clearances.
  • Installation, isolation, testing and maintenance must be performed by qualified personnel under applicable rules.

Accessory List

Designação do tipo

Code Position Code Symbol Meaning & Explanation
CQ Enterprise Code: Zhejiang Chuangqi Electric Co., LTD.
M Product Category: Molded Case Circuit Breaker
5 Design Serial Number
L Special Protection Function Residual Current Protection (Options: L=RC Protection)
125 Rated Frame Current (A): Options: 125, 250, 400, 630
Operation Mode:
• (No Code) – Manual Direct Operation
• Z – Rotary Handle Operation
• P – Electric Operation
4 Number of Poles:
• 3 – Three Poles
• 4 – Four Poles
300 Trip Unit & Accessories Code:
• 3 – Electronic Trip (Compound Trip)
• 2 – Magnetic Trip Only (Single Magnetic Trip)
• 00 – No Accessories (Refer to accessory table for specific codes)
Application Type:
• (No Code) – Distribution Protection
• 2 – Motor Protection
B N-Pole Type (For 4P products only, 3P has no code):
• Type A: N-pole is always connected, without overcurrent release.
• Type B: N-pole breaks with other poles, without overcurrent release.
• Type C: N-pole breaks with other poles, with overcurrent release.
• Type D: N-pole is always connected, with overcurrent release.
125A Rated Current: See technical parameter table for available values.
Y Time-Delay Function
• Y: With Delay
• F: Without Delay
Terminal & Connection Type:
• (No Code) – Front Terminal Connection
• B – Rear Terminal Connection
• C – Plug-in Type

Especificações Técnicas

Número do modelo CQM5L-125 CQM5L-250
Rated current of frame level Inm(A) 125 250
Rated current In(A),at 40℃ 10, 16, 20, 32, 40, 50, 63, 80, 100, 125 100, 125, 140, 160, 180, 200, 225, 250
Rated operating voltage Ue(V) AC380/400/415V AC380/400/415V
Rated insulation voltage Ui (V) 1000 1000
Tensão nominal de impulso suportada Uimp (kV) 8 8
Vida mecânica 20000 20000
Electrical life(AC415V) 8000 8000
Trip mechanisms and protection types Thermal-magnetic trip Thermal-magnetic trip
Selectivity category A A
Número de polos 3P, 4P 3P, 4P
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (kA) 70 70
Rated Service Short-Circuit Breaking Capacity (Ics) (kA) 50 50
Rated Residual Operating Current (IΔn) Time-delayed + Non-delayed 100/300/500 100/300/500
Non-delayed only 30/100/300/500 /
Rated Residual Current Type AC type AC type
Rated Residual Making & Breaking Capacity (IΔm) 1/4Icu 1/4Icu
Phase spacing (mm) 30 35
Arc distance (mm) ≤50 ≤50
Operating ambient temp -35 ℃ to +70℃ -35℃ to +70℃
Accessory Auxiliary contacts
Alarm contacts
Shunt Release
Under-Voltage Release
Motor Operating Mechanism
Manual Handle Assembly
Fixed Type Rear-Mounting Kit
Plug-in Type, Front-of-Panel
Plug-in Type, Rear-of-Panel
Mechanical Interlock
Instantaneous protection Power distribution protection In≤40A: 400A; In≥50A: 10In Entrada de 10 polegadas
Electric motor protection In≤40A: 400A; In≥50A: 12In 12In
Overall dimensions
(mm) (L-W-H)
3 P 155-90-90 165-105-103
4 P 155-120-90 165-140-103

Note:● for optional accessories;”-”for no optional accessories.

Número do modelo CQM5L-400 CQM5L-630
Rated current of frame level Inm(A) 400 630
Rated current In(A),at 40℃ 225, 250, 315, 350, 400 400, 500, 630
Rated operating voltage Ue(V) AC380/400/415V AC380/400/415V
Rated insulation voltage Ui (V) 1000 1000
Tensão nominal de impulso suportada Uimp (kV) 8 8
Vida mecânica 10000 10000
Electrical life(AC415V) 7000 7000
Trip mechanisms and protection types Thermal-magnetic trip Thermal-magnetic trip
Selectivity category A A
Número de polos 3P, 4P 3P, 4P
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (kA) 70 70
Rated Service Short-Circuit Breaking Capacity (Ics) (kA) 70 70
Rated Residual Operating Current (IΔn) Time-delayed + Non-delayed 100/300/500/1000 100/300/500/1000
Non-delayed only / /
Rated Residual Current Type AC type AC type
Rated Residual Making & Breaking Capacity (IΔm) 1/4Icu 1/4Icu
Phase spacing (mm) 48 70
Arc distance (mm) ≤100 ≤100
Operating ambient temp -35 ℃ to +70℃ -35℃ to +70℃
Accessory Auxiliary contacts
Alarm contacts
Shunt Release
Under-Voltage Release
Motor Operating Mechanism
Manual Handle Assembly
Fixed Type Rear-Mounting Kit
Plug-in Type, Front-of-Panel
Plug-in Type, Rear-of-Panel
Mechanical Interlock
Instantaneous protection Power distribution protection Entrada de 10 polegadas Entrada de 10 polegadas
Electric motor protection 12In 12In
Overall dimensions
(mm) (L-W-H)
3 P 257-150-104.5 280-210-112
4 P 257-198-104.5 280-280-112

Note:● for optional accessories;”-”for no optional accessories.

Dimensões (mm)

CQM5L-125

Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3P breakers)

CQM5L-250

Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3P breakers)

CQM5L-400

Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3P breakers)

CQM5L-630

Front Terminal Connection Dimensions

Note: Undefined tolerances comply with grade GB/T 1804-80.

Porquê escolher a CHAC

Com mais de 30 anos de experiência em fabrico, mais de 1100 funcionários, mais de 100 milhões de postes
Com uma capacidade anual e um processo de produção automatizado 90%, a CHAC garante uma capacidade de produção estável e rigorosos
Controlo de qualidade para clientes OEM/ODM globais. O nosso sistema de fabrico interno suporta a longo prazo
cooperação para marcas elétricas, importadores e distribuidores.


30+

ANOS DE EXPERIÊNCIA

Especializado em fabrico de baixa tensão elétrica


1100+

FUNCIONÁRIOS

Equipa profissional garante qualidade e entrega estáveis


100M+

CAPACIDADE ANUAL DE POSTOS

Capacidade de produção em larga escala para satisfazer a procura global


90%

PRODUÇÃO AUTOMATIZADA

Automação avançada para alta eficiência e consistência

Linha de Montagem Automatizada

Linha de Montagem Automatizada

Laboratório de Ensaios

Laboratório de Ensaios

Injeção e Estampagem

Injeção e Estampagem

Inspeção de Qualidade

Inspeção de Qualidade

Certificação IEC
Certificação CE
Certificação CB
Certificação RoHS
Certificação ISO 14001

Um rigoroso sistema de controlo de qualidade garante que cada produto cumpre as normas globais.

O que podemos personalizar?

For CQM5L projects, CHAC can review private-label marking, packaging, approved appearance options, published 10–630A electrical configurations and technical-document requirements. Requests outside the published range are subject to engineering evaluation, testing, minimum order quantity and project feasibility.

Design de Caixa

Recinto
Design

Tamanhos de caixas personalizadas, estruturas e detalhes de instalação.

Design de Caixa
Configuração Interna

Interno
Configuração

Layout interno flexível e opções de arranjo de componentes.

Configuração Interna
Branding e Logótipo

Branding &
Logótipo

Logótipos de marca própria, placas de identificação e identificação da marca.

Branding e Logótipo
Design de Embalagem

Embalagem
Design

Caixas personalizadas, etiquetas, manuais e soluções de embalagem.

Design de Embalagem
Configuração Elétrica

Elétrico
Configuração

Instalação elétrica à medida com base nos requisitos da aplicação.

Configuração Elétrica
Suporte de Certificação

Certificação
Apoio

Apoio a normas e requisitos de conformidade do mercado-alvo.

Suporte de Certificação

Transferir

PDF

Disjuntor de Caixa Moldada Série CQM5

Visão geral completa de componentes elétricos de baixa tensão e referência para seleção de produtos.

Transferir PDF

SUP

Precisa de Documentos Técnicos?

Contacte-nos para folhas de dados, certificados, desenhos, orientação de seleção ou suporte a projetos OEM/ODM.

Contacte-nos

CQM5L Product FAQ

What is the CQM5L MCCB used for?

The CQM5L is specified for overload, short circuit and residual-current protection in AC 380/400/415V systems within the published 10–630A range. Suitability depends on the fault study, conductor coordination, enclosure and local rules.

How does residual-current protection work in the CQM5L?

The residual-current function monitors imbalance associated with earth leakage and trips at the selected sensitivity or delay. The waveform type, threshold, time delay, earthing arrangement and local rules must be confirmed for the exact configuration.

How do I choose the CQM5L rated current and poles?

Start with the design current and conductor calculation, then choose a published current within 10–630A and poles from 3P / 4P. Neutral treatment, fault level, ambient conditions and coordination also need review.

What breaking capacity should I check on the CQM5L?

Use the declared 70kA Icu; 50kA or 70kA Ics by configuration for the exact frame, voltage and configuration. The prospective short-circuit current at the installation point must be within the applicable duty; a larger ampere value alone is not a selection rule.

Can the CQM5L replace an MCB or an earth-leakage device?

An MCCB is not automatically a like-for-like replacement. The CQM5L provides overload, short circuit and residual-current protection; residual-current protection, DC interruption, adjustable settings and other functions must be confirmed separately from the project requirement.

How should the CQM5L be installed and tested?

Use only the exact model drawing, terminal identification and accessory instructions. A qualified person should verify isolation, conductor size, torque, clearances, settings, fault duty and functional tests before energising the circuit.

Confirm the Right CQM5L Configuration

Send the frame, rated current, poles, protection function, system voltage, expected fault level, destination market and quantity. CHAC will review the request against the published model range.

Pedir um orçamento