CQM5L Series Residual Current Circuit Breaker

The CQM5L series circuit breaker with residual current protection is designed by CHAC Electric for use in AC 50Hz/60Hz circuits with a rated working voltage up to AC 415V and a rated working current up to 630A.

Poles:
3P / 4P

Rated Current:
10A–630A

Rated Voltage:
380/400/415V AC

Rated ultimate short-circuit breaking capacity:
70kA

Rated Service Short-Circuit Breaking Capacity:
50kA / 70kA

Standard:
IEC 60947-2
Customization:
One-Stop OEM/ODM Service

Product Features

■ Compact design with highbreaking capacity.

■ High short-circuit making capacity and vibration resistance.

■ Modular structure for quick and easy installation.

■ Provides overload, short-circuit, and residual current (earth fault) protection.

■ Adjustable residual current protection with selectable delay levels (3 or 4 stages) and configurable leakage trip current.

■ Equipped with a leakage trip indicator.

■ Suitable for circuits with AC voltage up to 415V and frequency 50Hz/60Hz.

■ Complies with GB/T 14048.2 and IEC 60947-2 standards.

Operating & Installation Conditions

■ Ambient temperature: -5℃ to +40℃ (average ≤ +35℃ within 24 hours)

■ Altitude ≤2000 meters above sea level.

■ Relative humidity ≤50% at +40℃.

■ Must be mounted vertically with tilt tolerance within ±5°.

■ Pollution degree: 3.

■ Suitable for protection in in distribution and motor circuits.

Accessory List

Type designation

Code Position Code Symbol Meaning & Explanation
CQ Enterprise Code: Zhejiang Chuangqi Electric Co., LTD.
M Product Category: Molded Case Circuit Breaker
5 Design Serial Number
L Special Protection Function Residual Current Protection (Options: L=RC Protection)
125 Rated Frame Current (A): Options: 125, 250, 400, 630
Operation Mode:
• (No Code) – Manual Direct Operation
• Z – Rotary Handle Operation
• P – Electric Operation
4 Number of Poles:
• 3 – Three Poles
• 4 – Four Poles
300 Trip Unit & Accessories Code:
• 3 – Electronic Trip (Compound Trip)
• 2 – Magnetic Trip Only (Single Magnetic Trip)
• 00 – No Accessories (Refer to accessory table for specific codes)
Application Type:
• (No Code) – Distribution Protection
• 2 – Motor Protection
B N-Pole Type (For 4P products only, 3P has no code):
• Type A: N-pole is always connected, without overcurrent release.
• Type B: N-pole breaks with other poles, without overcurrent release.
• Type C: N-pole breaks with other poles, with overcurrent release.
• Type D: N-pole is always connected, with overcurrent release.
125A Rated Current: See technical parameter table for available values.
Y Time-Delay Function
• Y: With Delay
• F: Without Delay
Terminal & Connection Type:
• (No Code) – Front Terminal Connection
• B – Rear Terminal Connection
• C – Plug-in Type

Technical Specifications

Model number CQM5L-125 CQM5L-250
Rated current of frame level Inm(A) 125 250
Rated current In(A),at 40℃ 10, 16, 20, 32, 40, 50, 63, 80, 100, 125 100, 125, 140, 160, 180, 200, 225, 250
Rated operating voltage Ue(V) AC380/400/415V AC380/400/415V
Rated insulation voltage Ui (V) 1000 1000
Rated impulse withstand voltage Uimp(kV) 8 8
Mechanical life 20000 20000
Electrical life(AC415V) 8000 8000
Trip mechanisms and protection types Thermal-magnetic trip Thermal-magnetic trip
Selectivity category A A
Number of poles 3P, 4P 3P, 4P
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (kA) 70 70
Rated Service Short-Circuit Breaking Capacity (Ics) (kA) 50 50
Rated Residual Operating Current (IΔn) Time-delayed + Non-delayed 100/300/500 100/300/500
Non-delayed only 30/100/300/500 /
Rated Residual Current Type AC type AC type
Rated Residual Making & Breaking Capacity (IΔm) 1/4Icu 1/4Icu
Phase spacing (mm) 30 35
Arc distance (mm) ≤50 ≤50
Operating ambient temp -35 ℃ to +70℃ -35℃ to +70℃
Accessory Auxiliary contacts
Alarm contacts
Shunt Release
Under-Voltage Release
Motor Operating Mechanism
Manual Handle Assembly
Fixed Type Rear-Mounting Kit
Plug-in Type, Front-of-Panel
Plug-in Type, Rear-of-Panel
Mechanical Interlock
Instantaneous protection Power distribution protection In≤40A: 400A; In≥50A: 10In 10In
Electric motor protection In≤40A: 400A; In≥50A: 12In 12In
Overall dimensions
(mm) (L-W-H)
3 P 155-90-90 165-105-103
4 P 155-120-90 165-140-103

Note:● for optional accessories;”-”for no optional accessories.

Model number CQM5L-400 CQM5L-630
Rated current of frame level Inm(A) 400 630
Rated current In(A),at 40℃ 225, 250, 315, 350, 400 400, 500, 630
Rated operating voltage Ue(V) AC380/400/415V AC380/400/415V
Rated insulation voltage Ui (V) 1000 1000
Rated impulse withstand voltage Uimp(kV) 8 8
Mechanical life 10000 10000
Electrical life(AC415V) 7000 7000
Trip mechanisms and protection types Thermal-magnetic trip Thermal-magnetic trip
Selectivity category A A
Number of poles 3P, 4P 3P, 4P
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (kA) 70 70
Rated Service Short-Circuit Breaking Capacity (Ics) (kA) 70 70
Rated Residual Operating Current (IΔn) Time-delayed + Non-delayed 100/300/500/1000 100/300/500/1000
Non-delayed only / /
Rated Residual Current Type AC type AC type
Rated Residual Making & Breaking Capacity (IΔm) 1/4Icu 1/4Icu
Phase spacing (mm) 48 70
Arc distance (mm) ≤100 ≤100
Operating ambient temp -35 ℃ to +70℃ -35℃ to +70℃
Accessory Auxiliary contacts
Alarm contacts
Shunt Release
Under-Voltage Release
Motor Operating Mechanism
Manual Handle Assembly
Fixed Type Rear-Mounting Kit
Plug-in Type, Front-of-Panel
Plug-in Type, Rear-of-Panel
Mechanical Interlock
Instantaneous protection Power distribution protection 10In 10In
Electric motor protection 12In 12In
Overall dimensions
(mm) (L-W-H)
3 P 257-150-104.5 280-210-112
4 P 257-198-104.5 280-280-112

Note:● for optional accessories;”-”for no optional accessories.

Dimensions (mm)

CQM5L-125

Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3P breakers)

CQM5L-250

Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3P breakers)

CQM5L-400

Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3P breakers)

CQM5L-630

Front Terminal Connection Dimensions

Note: Undefined tolerances comply with grade GB/T 1804-80.

Why Choose CHAC

With 30+ years of manufacturing experience, 1100+ employees, 100M+ poles
annual capacity and 90% automated production, CHAC provides stable production capacity and strict
quality control for global OEM/ODM customers. Our in-house manufacturing system supports long-term
cooperation for electrical brands, importers and distributors.


30+

YEARS EXPERIENCE

Specialized in low-voltage electrical manufacturing


1100+

EMPLOYEES

Professional team ensures stable quality and delivery


100M+

POLES ANNUAL CAPACITY

Large-scale production capacity to meet global demand


90%

AUTOMATED PRODUCTION

Advanced automation for high efficiency and consistency

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

IEC Certification
CE Certification
CB Certification
RoHS Certification
ISO 14001 Certification

Strict quality control system ensures every product meets global standards.

What Can We Customize?

Flexible customization services are available for enclosure dimensions, component configuration,
branding and project requirements.

Enclosure Design

Enclosure
Design

Customized enclosure sizes, structures and installation details.

Enclosure Design
Internal Configuration

Internal
Configuration

Flexible internal layout and component arrangement options.

Internal Configuration
Branding and Logo

Branding &
Logo

Private label logos, nameplates and brand identification.

Branding and Logo
Packaging Design

Packaging
Design

Custom cartons, labels, manuals and packaging solutions.

Packaging Design
Electrical Configuration

Electrical
Configuration

Tailored electrical setup based on application requirements.

Electrical Configuration
Certification Support

Certification
Support

Support for target-market standards and compliance requirements.

Certification Support

Descargar

PDF

CQM5 Series Moulded Case Circuit Breaker

Complete product overview for low-voltage electrical components and product selection reference.

Download PDF

SUP

Need Technical Documents?

Contact us for datasheets, certificates, drawings, selection guidance or OEM/ODM project support.

Contáctanos

Frequently Asked Questions

¿Admite la personalización de productos según nuestros requisitos de diseño?

A1:Absolutely. We specialize in OEM and ODM cooperation in the low-voltage electrical field and have provided customized services for many internationally renowned companies. We offer full-process support, including R&D design, parameter adjustments, and special material selection, ensuring the product fully meets your requirements.

P2: ¿Cuál es tu capacidad de producción y Cantidad Mínima de Pedido (MOQ)?

A2: We operate a highly automated production base with an annual output of over 100 million poles for miniature circuit breakers. Our MOQ policy is flexible. We can provide competitive trial orders for small batches and dedicated production capacity guarantee plans.

P3: ¿Qué garantías hay sobre la calidad del producto y las certificaciones?

A3: Our main products are certified with CCC, CE, CB, and more, and are sold in over 30 countries and regions worldwide. The company has established a dedicated Quality Operations Center that works with the business and production departments to implement full-process quality control, ensuring products meet international standards.

Q4: Do you have the capability for product R&D and turning concepts into reality?

A4: We have a complete R&D team and digital workshops, backed by extensive customization experience serving numerous international clients. From concept proposal and sample development to mass production, we provide end-to-end technical support to help bring your ideas to life.